Author: mav
Date: Sat Jan 17 17:40:44 2009
New Revision: 187368
URL: http://svn.freebsd.org/changeset/base/187368

Log:
  Convert battery capacity/rate from mA to mW only when summary is requested.
  Unconditional conversion causes incorrect rate units reported by acpiconf.
  
  MFC after:    2 weeks

Modified:
  head/sys/dev/acpica/acpi_battery.c

Modified: head/sys/dev/acpica/acpi_battery.c
==============================================================================
--- head/sys/dev/acpica/acpi_battery.c  Sat Jan 17 16:37:13 2009        
(r187367)
+++ head/sys/dev/acpica/acpi_battery.c  Sat Jan 17 17:40:44 2009        
(r187368)
@@ -197,7 +197,7 @@ acpi_battery_get_battinfo(device_t dev, 
         * is 0 (due to some error reading the battery), skip this
         * conversion.
         */
-       if (bif->units == ACPI_BIF_UNITS_MA && bif->dvol != 0) {
+       if (bif->units == ACPI_BIF_UNITS_MA && bif->dvol != 0 && dev == NULL) {
            bst[i].rate = (bst[i].rate * bif->dvol) / 1000;
            bst[i].cap = (bst[i].cap * bif->dvol) / 1000;
            bif->lfcap = (bif->lfcap * bif->dvol) / 1000;
_______________________________________________
svn-src-all@freebsd.org mailing list
http://lists.freebsd.org/mailman/listinfo/svn-src-all
To unsubscribe, send any mail to "svn-src-all-unsubscr...@freebsd.org"

Reply via email to