I could refer you back to Prof Angelo Farina’s input on the subject.

He confirmed the 3dB increase in noise per order. 

Just out of interest - who designed your encoder?

The increase in signal level was when you add two back to back cardioids was 
also confirmed by someone whose opinion I suspect you would trust even more 
than Angelo. 

Perhaps Prof Farina will chime in with his opinion.

The link you posted doesn’t lead anywhere useful by the way, it just takes you 
to a particular Facebook group. 

J
Sent from my iPhone

> On 9 Nov 2023, at 12:56, lenmoskow...@optonline.net wrote:
> 
> 
>> You get a 3dB increase of noise per order of ambisonics, which is why 
>> eight-capsule hybrid second order microphones can actually sound noisier 
>> than first order microphones.
>  
> That's true only if you don't know how to properly design an HOA encoder.
>  
>  
> Len Moskowitz (mosko...@core-sound.com)