Hi!
 
There are some new things I experienced with the previouse described problem:
 
    Source-Machine:         WindowsXP
    Destination-Machine:   Windows2003 Server
 
I wrote a simple java socket program and with this I didn't get any Socket 
exception, while I'm opening more simultaniouse connections. 
 
But if I just listen to the Port where STAF is running at the server, I get a 
"SocketException: Connection refused".
 
Maybe this information helps something to find the problem!
 
Best Regards


________________________________

From: Dominik Graf 
Sent: Dienstag, 23. Juni 2009 13:19
To: 'David Bender'; staf-users@lists.sourceforge.net
Cc: Gottfried Poell
Subject: RE: [staf-users] max number of simultanuous requests


Hi! 
 
We contacted you some time ago regarding the problem "max number of 
simultaneous requests". Finally I found the time to check your 
solution-suggestion, but it didn't work for us. 
 
First we even hadn't this TcpNumConnections parameter, but it didn't make any 
changes when I added it to the registry.
 
I tried it now with different operating systems and if I execute the requests 
from an WinXP to a Win2003 I get this Error submitting request, RC: 22.
But If I send the requests from Win2003 to Win2003 it is no problem. Even if I 
execute if from Win2003 to WinXP it is no problem.
 
To reproduce it, I created a batch file with this staf-request "staf %1 ping 
ping" and then I created another batch file which starts this batch file 
several times like: 
    start testping.bat SOME_IP
    start testping.bat SOME_IP
    ...
 
Maybe you can also reproduce it and give me some other solution!
 
Best Thanks in advance!
 
br,
Dominik
 
 

________________________________

From: David Bender [mailto:bda...@us.ibm.com] 
Sent: Dienstag, 19. Mai 2009 17:37
To: staf-users@lists.sourceforge.net
Cc: Dominik Graf; Gottfried Poell
Subject: Re: [staf-users] max number of simultanuous requests



Is it possible that you are encountering a TCPIP limitation on your Windows 
system?  Can you open the Windows registry and check the TCPIP settings?  The 
following document has some information: 
http://support.microsoft.com/default.aspx?kbid=314053.  In particular check the 
TcpNumConnections parameter. 

Several years ago we helped someone with a similar problem (when running 
multiple requests from a Windows system, a limitation was reached on the number 
of remote connections).  In their environment they were using a 10MB router 
which was causing the limiation, and upgrading their router to a 100MB router 
resovled the problem.  Can you check your adapter/network settings? 

On your Windows system, can you make more that 5 simultaneous TCPIP 
connections?  For example, telnet from the Windows systems to 6 remote systems 
and see if that works. 

David Bender
STAF/STAX Development
(512-286-5315)
IBM Austin Bldg. 903-5B002
Internet: bda...@us.ibm.com




Gottfried Poell <gottfried.po...@bwin.org> 

05/19/2009 09:29 AM 

To
Sharon Lucas/Austin/i...@ibmus 
cc
Dominik Graf <dominik.g...@bwin.org>, staf-users@lists.sourceforge.net 
Subject
Re: [staf-users] max number of simultanuous requests    

                




hello, 
  
thank you for your quick answer. 
  
we can reproduce this every time we try it. 
  
staf someIP VAR LIST produces 
  
H:\>staf 10.130.22.11 VAR LIST
Response
--------
STAF/Config/BootDrive           : C:
STAF/Config/CodePage            : IBM-850
STAF/Config/ConfigFile          : C:\STAF\bin\STAF.cfg
STAF/Config/DefaultAuthenticator: none
STAF/Config/DefaultInterface    : tcp
STAF/Config/InstanceName        : STAF
STAF/Config/Machine             : IXOPVH022011.baw.local
STAF/Config/MachineNickname     : IXOPVH022011.baw.local
STAF/Config/Mem/Physical/Bytes  : 2146922496
STAF/Config/Mem/Physical/KB     : 2096604
STAF/Config/Mem/Physical/MB     : 2047
STAF/Config/OS/MajorVersion     : 5
STAF/Config/OS/MinorVersion     : 2
STAF/Config/OS/Name             : Win2003
STAF/Config/OS/Revision         : 3790
STAF/Config/Sep/Command         : &
STAF/Config/Sep/File            : \
STAF/Config/Sep/Line            : 
  
STAF/Config/Sep/Path            : ;
STAF/Config/STAFRoot            : C:\STAF
STAF/Config/StartupTime         : 20090519-13:19:54
STAF/DataDir                    : C:\STAF\data\STAF
STAF/Env/ALLUSERSPROFILE        : C:\Documents and Settings\All Users
STAF/Env/APPDATA                : C:\Documents and 
Settings\srv-autotest\Application Data
STAF/Env/CLASSPATH              : 
C:\STAF\bin\JSTAF.jar;C:\STAF\samples\demo\STAFDemo.jar
STAF/Env/CLIENTNAME             : WIEWRK347
STAF/Env/ClusterLog             : C:\WINDOWS\Cluster\cluster.log
STAF/Env/CommonProgramFiles     : C:\Program Files\Common Files
STAF/Env/COMPUTERNAME           : IXOPVH022011
STAF/Env/ComSpec                : C:\WINDOWS\system32\cmd.exe
STAF/Env/FP_NO_HOST_CHECK       : NO
STAF/Env/HOMEDRIVE              : C:
STAF/Env/HOMEPATH               : \Documents and Settings\srv-autotest
STAF/Env/LOGONSERVER            : \\IXOPVH022011 <file://IXOPVH022011/> 
STAF/Env/NUMBER_OF_PROCESSORS   : 4
STAF/Env/OS                     : Windows_NT
STAF/Env/Path                   : 
C:\STAF\bin;D:\app\srv-autotest\product\11.1.0\client_1;D:\app\srv-autotest\product\11.1.0\client_1\bin;C:\Program
 
Files\OpenSSH\bin;C:\WINDOWS\system32;C:\WINDOWS;C:\WINDOWS\System32\Wbem;C:\WINDOWS\system32\WindowsPowerShell\v1.0
STAF/Env/PATHEXT                : 
.COM;.EXE;.BAT;.CMD;.VBS;.VBE;.JS;.JSE;.WSF;.WSH;.PSC1
STAF/Env/PROCESSOR_ARCHITECTURE : x86
STAF/Env/PROCESSOR_IDENTIFIER   : x86 Family 15 Model 33 Stepping 2, 
AuthenticAMD
STAF/Env/PROCESSOR_LEVEL        : 15
STAF/Env/PROCESSOR_REVISION     : 2102
STAF/Env/ProgramFiles           : C:\Program Files
STAF/Env/SESSIONNAME            : RDP-Tcp#1
STAF/Env/STAFCONVDIR            : C:\STAF\codepage
STAF/Env/SystemDrive            : C:
STAF/Env/SystemRoot             : C:\WINDOWS
STAF/Env/TCLLIBPATH             : C:\STAF\bin
STAF/Env/TEMP                   : C:\DOCUME~1\SRV-AU~1\LOCALS~1\Temp\1
STAF/Env/TMP                    : C:\DOCUME~1\SRV-AU~1\LOCALS~1\Temp\1
STAF/Env/USERDOMAIN             : IXOPVH022011
STAF/Env/USERNAME               : srv-autotest
STAF/Env/USERPROFILE            : C:\Documents and Settings\srv-autotest
STAF/Env/windir                 : C:\WINDOWS
STAF/Version                    : 3.2.5 
  
thx & br, 
Gottfried Pöll 


________________________________

From: Sharon Lucas [mailto:luc...@us.ibm.com] 
Sent: Dienstag, 19. Mai 2009 16:08
To: Gottfried Poell
Cc: Dominik Graf; staf-users@lists.sourceforge.net
Subject: Re: [staf-users] max number of simultanuous requests


What version of STAF are you running on these machines? 
What's the output of:  STAF someIP VAR LIST? 

We submit many (> 6) simultaneous requests to an endpoint without issues.

--------------------------------------------------------------
Sharon Lucas
IBM Austin,   luc...@us.ibm.com
(512) 286-7313 or Tieline 363-7313



Gottfried Poell <gottfried.po...@bwin.org> 

05/19/2009 08:05 AM 



To
<staf-users@lists.sourceforge.net> 
cc
Dominik Graf <dominik.g...@bwin.org> 
Subject
[staf-users] max number of simultanuous requests        


                





hello, 
 
we are experiencing connection problems as soon as the number of nearly 
simultanuous requests to a endpoint reaches the number of 6 
 
we are using the event-service but even the command "staf someIP ping ping" is 
not working. 
 
here is the result we get in the 6th or above request 
Error submitting request, RC: 22
Additional info
---------------
STAFConnectionWriteUInt: Error writing to socket: send() RC=10054: 22 
 
for testing purposes we just tried to execute a batch process which calls other 
batch files nearly simulatneously. 
 
 
can you help us with this issue? 
 
thx & br 
Gottfried 
Pöll------------------------------------------------------------------------------
Crystal Reports - New Free Runtime and 30 Day Trial
Check out the new simplified licensing option that enables 
unlimited royalty-free distribution of the report engine 
for externally facing server and web deployment. 
http://p.sf.net/sfu/businessobjects_______________________________________________
staf-users mailing list
staf-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/staf-users
------------------------------------------------------------------------------
Crystal Reports - New Free Runtime and 30 Day Trial
Check out the new simplified licensing option that enables 
unlimited royalty-free distribution of the report engine 
for externally facing server and web deployment. 
http://p.sf.net/sfu/businessobjects_______________________________________________
staf-users mailing list
staf-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/staf-users


------------------------------------------------------------------------------
Enter the BlackBerry Developer Challenge  
This is your chance to win up to $100,000 in prizes! For a limited time, 
vendors submitting new applications to BlackBerry App World(TM) will have
the opportunity to enter the BlackBerry Developer Challenge. See full prize  
details at: http://p.sf.net/sfu/Challenge
_______________________________________________
staf-users mailing list
staf-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/staf-users

Reply via email to