On Wed, Jul 08, 2009 at 05:28:53PM +0000, Paul Goyette wrote: > Module Name: src > Committed By: pgoyette > Date: Wed Jul 8 17:28:53 UTC 2009 > > Modified Files: > src/sys/dev/sysmon: sysmon_envsys_events.c > > Log Message: > Initialize lims.sel_flags before using it. Prevents spurious limit > events being created for devices that don't provide internal limits. > > Thanks to Mattias for finding this.
That doesn't seem to fix ipmi0: ipmi0: critical over limit on 'FAN MOD 4D RPM' ipmi0: critical over limit on 'FAN MOD 4C RPM' ipmi0: critical over limit on 'FAN MOD 4B RPM' ipmi0: critical over limit on 'FAN MOD 4A RPM' ipmi0: critical over limit on 'FAN MOD 3D RPM' ipmi0: critical over limit on 'FAN MOD 3C RPM' ipmi0: critical over limit on 'FAN MOD 3B RPM' ipmi0: critical over limit on 'FAN MOD 3A RPM' ipmi0: critical over limit on 'FAN MOD 2D RPM' ipmi0: critical over limit on 'FAN MOD 2C RPM' ipmi0: critical over limit on 'FAN MOD 2B RPM' ipmi0: critical over limit on 'FAN MOD 2A RPM' ipmi0: critical over limit on 'FAN MOD 1D RPM' ipmi0: critical over limit on 'FAN MOD 1C RPM' ipmi0: critical over limit on 'FAN MOD 1B RPM' ipmi0: critical over limit on 'FAN MOD 1A RPM' ipmi0: critical over limit on 'Ambient Temp' ipmi0: critical over limit on 'Temp3' # envstat -d ipmi0 -W Current WarnMax WarnMin WarnCap Unit Voltage 2: N/A Voltage 1: N/A Intrusion: ON Status1: OFF Status: OFF FAN MOD 4D RPM: 3750 RPM FAN MOD 4C RPM: 3675 RPM FAN MOD 4B RPM: 6075 RPM FAN MOD 4A RPM: 6000 RPM FAN MOD 3D RPM: 3675 RPM FAN MOD 3C RPM: 3750 RPM FAN MOD 3B RPM: 5850 RPM FAN MOD 3A RPM: 6225 RPM FAN MOD 2D RPM: 3750 RPM FAN MOD 2C RPM: 3825 RPM FAN MOD 2B RPM: 6075 RPM FAN MOD 2A RPM: 5850 RPM FAN MOD 1D RPM: 3750 RPM FAN MOD 1C RPM: 3750 RPM FAN MOD 1B RPM: 5850 RPM FAN MOD 1A RPM: 5925 RPM Ambient Temp: 22.000 degC Temp3: 40.000 degC Temp2: 40.000 degC Temp1: 50.000 degC Temp: -54.000 degC # envstat -d ipmi0 Current CritMax CritMin CritCap Unit Voltage 2: N/A Voltage 1: N/A Intrusion: ON Status1: OFF Status: OFF FAN MOD 4D RPM: 3750 1575 RPM FAN MOD 4C RPM: 3675 1575 RPM FAN MOD 4B RPM: 6075 1575 RPM FAN MOD 4A RPM: 6000 1575 RPM FAN MOD 3D RPM: 3675 1575 RPM FAN MOD 3C RPM: 3750 1575 RPM FAN MOD 3B RPM: 5850 1575 RPM FAN MOD 3A RPM: 6225 1575 RPM FAN MOD 2D RPM: 3750 1575 RPM FAN MOD 2C RPM: 3825 1575 RPM FAN MOD 2B RPM: 6075 1575 RPM FAN MOD 2A RPM: 5850 1575 RPM FAN MOD 1D RPM: 3750 1575 RPM FAN MOD 1C RPM: 3750 1575 RPM FAN MOD 1B RPM: 5850 1575 RPM FAN MOD 1A RPM: 5925 1575 RPM Ambient Temp: 22.000 degC Temp3: 40.000 degC Temp2: 40.000 degC Temp1: 50.000 degC Temp: -54.000 degC Dave -- David Young OJC Technologies dyo...@ojctech.com Urbana, IL * (217) 278-3933