smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.4.0-42-generic] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     TOSHIBA HDWN160
LU WWN Device Id: 5 000039 a2b900c39
Firmware Version: FS1M
User Capacity:    6,001,175,126,016 bytes [6.00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    7200 rpm
Form Factor:      3.5 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ATA8-ACS (minor revision not indicated)
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Sun Aug 23 12:22:53 2020 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (  120) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 638) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   100   100   050    Pre-fail  Always       
-       0
  2 Throughput_Performance  0x0005   100   100   050    Pre-fail  Offline      
-       0
  3 Spin_Up_Time            0x0027   100   100   001    Pre-fail  Always       
-       10406
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       
-       3
  5 Reallocated_Sector_Ct   0x0033   100   100   050    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000b   100   100   050    Pre-fail  Always       
-       0
  8 Seek_Time_Performance   0x0005   100   100   050    Pre-fail  Offline      
-       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       70
 10 Spin_Retry_Count        0x0033   100   100   030    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       3
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       
-       0
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       1
193 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       
-       10
194 Temperature_Celsius     0x0022   100   100   000    Old_age   Always       
-       29 (Min/Max 21/32)
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       
-       0
197 Current_Pending_Sector  0x0032   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0030   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x0032   200   253   000    Old_age   Always       
-       0
220 Disk_Shift              0x0002   100   100   000    Old_age   Always       
-       0
222 Loaded_Hours            0x0032   100   100   000    Old_age   Always       
-       68
223 Load_Retry_Count        0x0032   100   100   000    Old_age   Always       
-       0
224 Load_Friction           0x0022   100   100   000    Old_age   Always       
-       0
226 Load-in_Time            0x0026   100   100   000    Old_age   Always       
-       624
240 Head_Flying_Hours       0x0001   100   100   001    Pre-fail  Offline      
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%        70         -
# 2  Short offline       Completed without error       00%        65         -
# 3  Short offline       Completed without error       00%        41         -
# 4  Short offline       Completed without error       00%        18         -
# 5  Extended offline    Completed without error       00%        10         -
# 6  Short offline       Completed without error       00%         0         -
# 7  Short offline       Completed without error       00%         0         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to