smartctl 6.5 2016-05-07 r4318 [x86_64-w64-mingw32-win10] (sf-6.5-1)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: ST4000VX000-1F4168
Serial Number: Z3065Y2H
LU WWN Device Id: 5 000c50 0909615b4
Firmware Version: CV14
User Capacity: 4.000.787.030.016 bytes [4,00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5900 rpm
Form Factor: 3.5 inches
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 1.5 Gb/s)
Local Time is: Sat Jun 11 19:08:32 2016 MS
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, NOT FROZEN [SEC1]
Write SCT (Get) Feature Control Command failed: Read of ATA output registers
not implemented [JMicron]
Wt Cache Reorder: Unknown (SCT Feature Control command failed)
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 107) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 494) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x10b9) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 108 099 006 - 20454944
3 Spin_Up_Time PO---- 092 091 000 - 0
4 Start_Stop_Count -O--CK 100 100 020 - 618
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
7 Seek_Error_Rate POSR-- 072 060 030 - 15190442
9 Power_On_Hours -O--CK 098 098 000 - 2486
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 100 100 020 - 565
184 End-to-End_Error -O--CK 100 100 099 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
188 Command_Timeout -O--CK 100 100 000 - 0
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 066 066 045 - 34 (Min/Max 28/34)
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
192 Power-Off_Retract_Count -O--CK 100 100 000 - 1
193 Load_Cycle_Count -O--CK 100 100 000 - 618
194 Temperature_Celsius -O---K 034 040 000 - 34 (0 18 0 0 0)
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: 48-bit ATA commands not
implemented [JMicron]
Read GP Log Directory failed
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x08 SL R/O 2 Power Conditions log
0x09 SL R/W 1 Selective self-test log
0x30 SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f SL R/W 16 Host vendor specific log
0xa1 SL VS 20 Device vendor specific log
0xa8 SL VS 129 Device vendor specific log
0xa9 SL VS 1 Device vendor specific log
0xc1 SL VS 10 Device vendor specific log
0xc4 SL VS 5 Device vendor specific log
0xe0 SL R/W 1 SCT Command/Status
0xe1 SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
No Errors Logged
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 2469 -
# 2 Extended offline Completed without error 00% 2455 -
# 3 Short offline Completed without error 00% 2428 -
# 4 Short offline Completed without error 00% 2404 -
# 5 Short offline Completed without error 00% 2380 -
# 6 Short offline Completed without error 00% 2356 -
# 7 Short offline Completed without error 00% 2332 -
# 8 Extended offline Completed without error 00% 2316 -
# 9 Short offline Completed without error 00% 2260 -
#10 Short offline Completed without error 00% 2239 -
#11 Short offline Completed without error 00% 2223 -
#12 Short offline Completed without error 00% 2207 -
#13 Short offline Completed without error 00% 2183 -
#14 Short offline Completed without error 00% 2159 -
#15 Extended offline Completed without error 00% 2145 -
#16 Short offline Completed without error 00% 2118 -
#17 Short offline Completed without error 00% 2102 -
#18 Short offline Completed without error 00% 2086 -
#19 Short offline Completed without error 00% 2071 -
#20 Short offline Completed without error 00% 2047 -
#21 Short offline Completed without error 00% 2023 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 522 (0x020a)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 34 Celsius
Power Cycle Min/Max Temperature: 28/34 Celsius
Lifetime Min/Max Temperature: 18/34 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 94 minutes
Min/Max recommended Temperature: 1/61 Celsius
Min/Max Temperature Limit: 2/60 Celsius
Temperature History Size (Index): 128 (82)
Index Estimated Time Temperature Celsius
83 2016-06-03 11:08 32 *************
... ..( 7 skipped). .. *************
91 2016-06-03 23:40 32 *************
92 2016-06-04 01:14 31 ************
... ..( 26 skipped). .. ************
119 2016-06-05 19:32 31 ************
120 2016-06-05 21:06 32 *************
... ..( 17 skipped). .. *************
10 2016-06-07 01:18 32 *************
11 2016-06-07 02:52 31 ************
12 2016-06-07 04:26 32 *************
13 2016-06-07 06:00 31 ************
14 2016-06-07 07:34 32 *************
... ..( 4 skipped). .. *************
19 2016-06-07 15:24 32 *************
20 2016-06-07 16:58 31 ************
21 2016-06-07 18:32 32 *************
22 2016-06-07 20:06 32 *************
23 2016-06-07 21:40 32 *************
24 2016-06-07 23:14 31 ************
25 2016-06-08 00:48 31 ************
26 2016-06-08 02:22 31 ************
27 2016-06-08 03:56 32 *************
... ..( 8 skipped). .. *************
36 2016-06-08 18:02 32 *************
37 2016-06-08 19:36 31 ************
38 2016-06-08 21:10 ? -
39 2016-06-08 22:44 30 ***********
40 2016-06-09 00:18 ? -
41 2016-06-09 01:52 29 **********
42 2016-06-09 03:26 ? -
43 2016-06-09 05:00 28 *********
44 2016-06-09 06:34 ? -
45 2016-06-09 08:08 23 ****
46 2016-06-09 09:42 30 ***********
... ..( 3 skipped). .. ***********
50 2016-06-09 15:58 30 ***********
51 2016-06-09 17:32 31 ************
52 2016-06-09 19:06 30 ***********
53 2016-06-09 20:40 30 ***********
54 2016-06-09 22:14 32 *************
55 2016-06-09 23:48 32 *************
56 2016-06-10 01:22 32 *************
57 2016-06-10 02:56 31 ************
58 2016-06-10 04:30 31 ************
59 2016-06-10 06:04 32 *************
60 2016-06-10 07:38 31 ************
61 2016-06-10 09:12 30 ***********
... ..( 16 skipped). .. ***********
78 2016-06-11 11:50 30 ***********
79 2016-06-11 13:24 ? -
80 2016-06-11 14:58 28 *********
81 2016-06-11 16:32 ? -
82 2016-06-11 18:06 28 *********
Write SCT (Get) Error Recovery Control Command failed: Read of ATA output
registers not implemented [JMicron]
SCT (Get) Error Recovery Control command failed
Device Statistics (GP/SMART Log 0x04) not supported
ATA_READ_LOG_EXT (addr=0x11:0x00, page=0, n=1) failed: 48-bit ATA commands not
implemented [JMicron]
Read SATA Phy Event Counters failed
------------------------------------------------------------------------------
What NetFlow Analyzer can do for you? Monitors network bandwidth and traffic
patterns at an interface-level. Reveals which users, apps, and protocols are
consuming the most bandwidth. Provides multi-vendor support for NetFlow,
J-Flow, sFlow and other flows. Make informed decisions using capacity
planning reports. https://ad.doubleclick.net/ddm/clk/305295220;132659582;e
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database