Add to smartmontools-database Seagate-ST120HM000-1G5142

--
С уважением,
Игорь.
smartctl 6.4 2014-10-07 r4002 [x86_64-linux-4.2.0-35-lowlatency] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     ST120HM000-1G5142
Serial Number:    Z4M00CNX
LU WWN Device Id: 5 000c50 02ff18988
Firmware Version: C675
User Capacity:    120.034.123.776 bytes [120 GB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    Solid State Device
Form Factor:      2.5 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Sun Apr 24 10:29:23 2016 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Unavailable
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x02) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (    5) seconds.
Offline data collection
capabilities:                    (0x19) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0002) Does not save SMART data before
                                        entering power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  19) minutes.

SMART Attributes Data Structure revision number: 0
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     -OSR--   166   166   006    -    1
  5 Reallocated_Sector_Ct   PO--CK   100   100   036    -    0
  9 Power_On_Hours          -O--CK   082   082   000    -    15935
 12 Power_Cycle_Count       -O--CK   100   100   020    -    373
171 Unknown_Attribute       -O--CK   100   100   000    -    0
172 Unknown_Attribute       -O--CK   100   100   000    -    0
181 Program_Fail_Cnt_Total  -O--CK   100   100   000    -    0
182 Erase_Fail_Count_Total  -O--CK   100   100   000    -    0
194 Temperature_Celsius     -O---K   020   000   000    -    20 (Min/Max 12/56)
201 Unknown_SSD_Attribute   -O--CK   100   100   000    -    0
204 Soft_ECC_Correction     -O--CK   100   100   000    -    0
231 Temperature_Celsius     PO--C-   096   096   010    -    5
234 Unknown_Attribute       -O--CK   100   100   000    -    35398
241 Total_LBAs_Written      -O--CK   100   100   000    -    1536
242 Total_LBAs_Read         -O--CK   100   100   000    -    940
250 Read_Error_Retry_Rate   -O--CK   100   100   000    -    78
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x03       GPL,SL  R/O      5  Ext. Comprehensive SMART error log
0x04       GPL,SL  R/O      8  Device Statistics log
0x07       GPL,SL  R/O      2  Extended self-test log
0x10       GPL     R/O      1  SATA NCQ Queued Error log
0x11       GPL     R/O      1  SATA Phy Event Counters log
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xa8       GPL     VS     521  Device vendor specific log
0xa8       SL      VS     255  Device vendor specific log
0xb7       GPL,SL  VS       4  Device vendor specific log

SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 430 (device log contains only the most recent 20 errors)
        CR     = Command Register
        FEATR  = Features Register
        COUNT  = Count (was: Sector Count) Register
        LBA_48 = Upper bytes of LBA High/Mid/Low Registers ]  ATA-8
        LH     = LBA High (was: Cylinder High) Register    ]   LBA
        LM     = LBA Mid (was: Cylinder Low) Register      ] Register
        LL     = LBA Low (was: Sector Number) Register     ]
        DV     = Device (was: Device/Head) Register
        DC     = Device Control Register
        ER     = Error register
        ST     = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 430 [9] occurred at disk power-on lifetime: 15934 hours (663 days + 22 
hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  04 -- 51 00 fe 00 00 00 00 00 00 40 08  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  ef 00 05 00 fe 00 00 00 00 00 00 40 08     00:00:40.540  SET FEATURES [Enable 
APM]
  60 00 08 00 00 00 00 05 87 05 70 40 08     00:00:40.540  READ FPDMA QUEUED
  60 01 b8 00 f0 00 00 09 a2 f2 b0 40 08     00:00:40.540  READ FPDMA QUEUED
  60 00 08 00 e0 00 00 05 06 fd 10 40 08     00:00:40.540  READ FPDMA QUEUED
  60 01 00 00 d8 00 00 0d 83 c0 00 40 08     00:00:40.540  READ FPDMA QUEUED

Error 429 [8] occurred at disk power-on lifetime: 15921 hours (663 days + 9 
hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  04 -- 51 00 fe 00 00 00 00 00 00 40 08  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  ef 00 05 00 fe 00 00 00 00 00 00 40 08     13:58:00.070  SET FEATURES [Enable 
APM]
  60 01 00 00 a0 00 00 0d 81 34 00 40 08     13:58:00.070  READ FPDMA QUEUED
  60 00 50 00 98 00 00 03 82 71 a8 40 08     13:58:00.070  READ FPDMA QUEUED
  60 01 a8 00 90 00 00 03 82 6f f8 40 08     13:58:00.070  READ FPDMA QUEUED
  60 00 08 00 88 00 00 03 82 71 a0 40 08     13:58:00.070  READ FPDMA QUEUED

Error 428 [7] occurred at disk power-on lifetime: 15907 hours (662 days + 19 
hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  04 -- 51 00 fe 00 00 00 00 00 00 40 08  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  ef 00 05 00 fe 00 00 00 00 00 00 40 08     00:00:40.480  SET FEATURES [Enable 
APM]
  60 00 08 00 40 00 00 00 46 f9 50 40 08     00:00:40.480  READ FPDMA QUEUED
  60 00 40 00 38 00 00 0c 8a 6a c0 40 08     00:00:40.480  READ FPDMA QUEUED
  60 00 20 00 30 00 00 00 4c bf e0 40 08     00:00:40.480  READ FPDMA QUEUED
  60 01 00 00 18 00 00 0d 83 be 00 40 08     00:00:40.480  READ FPDMA QUEUED

Error 427 [6] occurred at disk power-on lifetime: 15907 hours (662 days + 19 
hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  04 -- 51 00 fe 00 00 00 00 00 00 40 08  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  ef 00 05 00 fe 00 00 00 00 00 00 40 08     09:59:02.070  SET FEATURES [Enable 
APM]
  60 00 08 00 38 00 00 05 06 39 98 40 08     09:59:02.070  READ FPDMA QUEUED
  60 00 38 00 18 00 00 05 06 39 d0 40 08     09:59:02.070  READ FPDMA QUEUED
  60 01 00 00 10 00 00 0d 83 bb 00 40 08     09:59:02.060  READ FPDMA QUEUED
  60 00 08 00 08 00 00 05 06 39 c8 40 08     09:59:02.060  READ FPDMA QUEUED

Error 426 [5] occurred at disk power-on lifetime: 15897 hours (662 days + 9 
hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  04 -- 51 00 fe 00 00 00 00 00 00 40 08  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  ef 00 05 00 fe 00 00 00 00 00 00 40 08     00:00:40.080  SET FEATURES [Enable 
APM]
  60 01 00 00 40 00 00 0d 81 34 00 40 08     00:00:40.080  READ FPDMA QUEUED
  60 01 00 00 38 00 00 0d 81 33 00 40 08     00:00:40.080  READ FPDMA QUEUED
  60 00 08 00 30 00 00 05 89 f8 60 40 08     00:00:40.080  READ FPDMA QUEUED
  60 00 08 00 28 00 00 05 89 fb b8 40 08     00:00:40.080  READ FPDMA QUEUED

Error 425 [4] occurred at disk power-on lifetime: 15840 hours (660 days + 0 
hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  04 -- 51 00 fe 00 00 00 00 00 00 40 08  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  ef 00 05 00 fe 00 00 00 00 00 00 40 08     00:00:40.060  SET FEATURES [Enable 
APM]
  60 02 00 00 d0 00 00 0d 81 1c 00 40 08     00:00:40.060  READ FPDMA QUEUED
  60 00 08 00 c0 00 00 0b 86 f9 38 40 08     00:00:40.060  READ FPDMA QUEUED
  60 00 88 00 b8 00 00 0a 0c b6 f8 40 08     00:00:40.060  READ FPDMA QUEUED
  60 01 b8 00 b0 00 00 09 a2 f2 b0 40 08     00:00:40.060  READ FPDMA QUEUED

Error 424 [3] occurred at disk power-on lifetime: 15751 hours (656 days + 7 
hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  04 -- 51 00 fe 00 00 00 00 00 00 40 08  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  ef 00 05 00 fe 00 00 00 00 00 00 40 08     00:00:32.380  SET FEATURES [Enable 
APM]
  60 00 08 00 f0 00 00 05 86 f9 f8 40 08     00:00:32.380  READ FPDMA QUEUED
  60 00 38 00 e8 00 00 06 10 0c c8 40 08     00:00:32.380  READ FPDMA QUEUED
  60 00 08 00 e0 00 00 00 47 35 28 40 08     00:00:32.380  READ FPDMA QUEUED
  60 00 08 00 d8 00 00 05 8a 1a 28 40 08     00:00:32.380  READ FPDMA QUEUED

Error 423 [2] occurred at disk power-on lifetime: 15699 hours (654 days + 3 
hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  04 -- 51 00 fe 00 00 00 00 00 00 40 08  Error: ABRT

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  ef 00 05 00 fe 00 00 00 00 00 00 40 08     00:00:40.560  SET FEATURES [Enable 
APM]
  60 01 00 00 a8 00 00 0d 81 32 00 40 08     00:00:40.560  READ FPDMA QUEUED
  60 01 00 00 a0 00 00 0d 81 31 00 40 08     00:00:40.560  READ FPDMA QUEUED
  60 00 20 00 98 00 00 0a 5c a5 20 40 08     00:00:40.560  READ FPDMA QUEUED
  60 01 00 00 90 00 00 0d 81 30 00 40 08     00:00:40.560  READ FPDMA QUEUED

SMART Extended Self-test Log Version: 1 (2 sectors)
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%     15935         -
# 2  Short offline       Completed without error       00%     14064         -
# 3  Extended offline    Completed without error       00%        31         -

Selective Self-tests/Logging not supported

SCT Commands not supported

Device Statistics (GP Log 0x04)
Page Offset Size         Value  Description
  1  =====  =                =  == General Statistics (rev 2) ==
  1  0x008  4              373  Lifetime Power-On Resets

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x0001  2            0  Command failed due to ICRC error
0x0002  2            0  R_ERR response for data FIS
0x0003  2            0  R_ERR response for device-to-host data FIS
0x0004  2            0  R_ERR response for host-to-device data FIS
0x0005  2            0  R_ERR response for non-data FIS
0x0006  2            0  R_ERR response for device-to-host non-data FIS
0x0007  2            0  R_ERR response for host-to-device non-data FIS
0x0008  2            0  Device-to-host non-data FIS retries
0x0009  2            0  Transition from drive PhyRdy to drive PhyNRdy
0x000a  2            2  Device-to-host register FISes sent due to a COMRESET
0x000b  2            0  CRC errors within host-to-device FIS
0x000d  2            0  Non-CRC errors within host-to-device FIS
0x000f  2            0  R_ERR response for host-to-device data FIS, CRC
0x0010  2            0  R_ERR response for host-to-device data FIS, non-CRC
0x0012  2            0  R_ERR response for host-to-device non-data FIS, CRC
0x0013  2            0  R_ERR response for host-to-device non-data FIS, non-CRC

------------------------------------------------------------------------------
Find and fix application performance issues faster with Applications Manager
Applications Manager provides deep performance insights into multiple tiers of
your business applications. It resolves application problems quickly and
reduces your MTTR. Get your free trial!
https://ad.doubleclick.net/ddm/clk/302982198;130105516;z
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to