Hi, my SSD seems missing from the database. i have followed https://www.smartmontools.org/wiki/FAQ#MyATAdriveisnotinthesmartctlsmartddatabase (and first updated the database)
Thanks, Daniele
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-3.14.56-gentoo-Dom0-314-r4] (local build) Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: Corsair Neutron GTX SSD Serial Number: 14087914000097140111 Firmware Version: M311 User Capacity: 120,034,123,776 bytes [120 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 2.5, 6.0 Gb/s Local Time is: Tue Dec 29 15:50:29 2015 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART Status not supported: ATA return descriptor not supported by controller firmware SMART overall-health self-assessment test result: PASSED Warning: This result is based on an Attribute check. General SMART Values: Offline data collection status: (0x02) Offline data collection activity was completed without error. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 4) seconds. Offline data collection capabilities: (0x19) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0002) Does not save SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 5) minutes. SMART Attributes Data Structure revision number: 0 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate -OSR-- 166 166 006 - 0 5 Reallocated_Sector_Ct -O--CK 253 253 036 - 0 9 Power_On_Hours -O--CK 083 083 000 - 15598 12 Power_Cycle_Count -O--CK 100 100 000 - 43 171 Unknown_Attribute -O--CK 253 253 000 - 0 172 Unknown_Attribute -O--CK 253 253 000 - 0 181 Program_Fail_Cnt_Total -O--CK 253 253 000 - 0 182 Erase_Fail_Count_Total -O--CK 253 253 000 - 0 194 Temperature_Celsius -O---- 027 000 000 - 27 (Min/Max 18/40) 201 Unknown_SSD_Attribute -OSR-- 100 100 000 - 0 204 Soft_ECC_Correction -OSR-- 100 100 000 - 0 231 Temperature_Celsius PO--CK 098 098 010 - 3 234 Unknown_Attribute -O--CK 100 100 000 - 20751 241 Total_LBAs_Written -O--CK 100 100 000 - 13855 242 Total_LBAs_Read -O--CK 100 100 000 - 13391 250 Read_Error_Retry_Rate -O--CK 253 253 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory not supported SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 4 Comprehensive SMART error log 0x03 SL R/O 5 Ext. Comprehensive SMART error log 0x04 SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log SMART Extended Comprehensive Error Log (GP Log 0x03) not supported SMART Error Log Version: 1 ATA Error Count: 36302 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 36302 occurred at disk power-on lifetime: 15598 hours (649 days + 22 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 04 51 ff 00 4f c2 e0 Error: ABRT Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- b0 d5 81 04 4f c2 00 00 4d+19:53:16.080 SMART READ LOG b0 d5 01 04 4f c2 00 00 4d+19:53:16.080 SMART READ LOG b0 d5 01 06 4f c2 00 00 4d+19:53:16.080 SMART READ LOG b0 d5 01 01 4f c2 00 00 4d+19:53:16.070 SMART READ LOG b0 d5 01 00 4f c2 00 00 4d+19:53:16.070 SMART READ LOG Error 36301 occurred at disk power-on lifetime: 15528 hours (647 days + 0 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 00 00 00 00 00 00 00 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- e0 00 00 00 00 00 00 00 1d+21:21:04.350 STANDBY IMMEDIATE ea 00 00 00 00 00 00 00 1d+21:21:04.350 FLUSH CACHE EXT ea 00 00 00 00 00 00 00 1d+21:21:04.330 FLUSH CACHE EXT ea 00 00 00 00 00 00 00 1d+21:21:04.330 FLUSH CACHE EXT 61 08 00 00 08 00 40 40 1d+21:21:02.090 WRITE FPDMA QUEUED Error 36300 occurred at disk power-on lifetime: 15528 hours (647 days + 0 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 00 00 00 00 00 00 00 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- e0 00 00 00 00 00 00 00 1d+21:21:04.350 STANDBY IMMEDIATE ea 00 00 00 00 00 00 00 1d+21:21:04.350 FLUSH CACHE EXT ea 00 00 00 00 00 00 00 1d+21:21:04.330 FLUSH CACHE EXT ea 00 00 00 00 00 00 00 1d+21:21:04.330 FLUSH CACHE EXT 61 08 00 00 08 00 40 40 1d+21:21:02.090 WRITE FPDMA QUEUED Error 36299 occurred at disk power-on lifetime: 15482 hours (645 days + 2 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 00 00 00 00 00 00 00 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- Error 36298 occurred at disk power-on lifetime: 15482 hours (645 days + 2 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 00 00 00 00 00 00 00 at LBA = 0x00000000 = 0 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 61 00 18 00 61 d9 40 40 04:58:19.000 WRITE FPDMA QUEUED 61 08 10 f8 60 d9 40 40 04:58:19.000 WRITE FPDMA QUEUED 61 08 00 00 60 d9 40 40 04:58:19.000 WRITE FPDMA QUEUED 61 00 08 00 5f d9 40 40 04:58:19.000 WRITE FPDMA QUEUED 61 00 10 00 5e d9 40 40 04:58:19.000 WRITE FPDMA QUEUED SMART Extended Self-test Log (GP Log 0x07) not supported SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 15598 - Selective Self-tests/Logging not supported SCT Commands not supported Device Statistics (SMART Log 0x04) Page Offset Size Value Flags Description ATA_SMART_READ_LOG failed: megasas_cmd result: 4.18 = 0/45 Read Device Statistics pages 0x00-0x80 failed SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 4 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
------------------------------------------------------------------------------
_______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database