Greetings, I've uploaded two HDD that were not in your database? When you add them to your database, how long does that usually take and then what would I need to do next? I assume that updating the database gives more specific values to the attributes list.
Thanks DRC
smartctl 6.3 2014-07-26 r3976 [i686-w64-mingw32-win7-sp1] (sf-6.3-1) Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: INTEL SSDSA1NW160G3 Serial Number: CVPR3411000N160HGN LU WWN Device Id: 5 5cd2e4 04b846ccb Firmware Version: 4PC10362 User Capacity: 160,041,885,696 bytes [160 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Mon Oct 26 15:38:25 2015 CUT SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, NOT FROZEN [SEC1] Write SCT (Get) Feature Control Command failed: Read of ATA output registers not implemented [JMicron] Wt Cache Reorder: Unknown (SCT Feature Control command failed) === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 1) seconds. Offline data collection capabilities: (0x75) SMART execute Offline immediate. No Auto Offline data collection support. Abort Offline collection upon new command. No Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 1) minutes. Conveyance self-test routine recommended polling time: ( 1) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 5 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 3 Spin_Up_Time 0x0020 100 100 000 Old_age Offline - 0 4 Start_Stop_Count 0x0030 100 100 000 Old_age Offline - 0 5 Reallocated_Sector_Ct 0x0032 100 100 000 Old_age Always - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 270 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 222 170 Unknown_Attribute 0x0033 100 100 010 Pre-fail Always - 0 171 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0 172 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0 183 Runtime_Bad_Block 0x0030 100 100 000 Old_age Offline - 54 184 End-to-End_Error 0x0032 100 100 090 Old_age Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 55 199 UDMA_CRC_Error_Count 0x0030 100 100 000 Old_age Offline - 0 225 Unknown_SSD_Attribute 0x0032 100 100 000 Old_age Always - 29163 226 Unknown_SSD_Attribute 0x0032 100 100 000 Old_age Always - 21842318 227 Unknown_SSD_Attribute 0x0032 100 100 000 Old_age Always - 0 228 Power-off_Retract_Count 0x0032 100 100 000 Old_age Always - 42012522 232 Available_Reservd_Space 0x0033 100 100 010 Pre-fail Always - 0 233 Media_Wearout_Indicator 0x0032 100 100 000 Old_age Always - 0 241 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 29163 242 Total_LBAs_Read 0x0032 100 100 000 Old_age Always - 13687 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Vendor (0x68) Completed without error 00% 270 - # 2 Vendor (0x68) Completed without error 00% 270 - # 3 Vendor (0xa7) Completed without error 00% 269 - SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 1 (0x0001) SCT Support Level: 0 Device State: Active (0) Current Temperature: ? Celsius Power Cycle Min/Max Temperature: ?/ ? Celsius Lifetime Min/Max Temperature: ?/ ? Celsius Under/Over Temperature Limit Count: 0/0 Unexpected SCT status 0x0011 (action_code=5, function_code=1) Read SCT Temperature History failed
smartctl 6.3 2014-07-26 r3976 [i686-w64-mingw32-win7-sp1] (sf-6.3-1) Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: HGST HTS721050A9E630 Serial Number: JR14006Q0279RE LU WWN Device Id: 5 000cca 7d8c10432 Firmware Version: JB6OA3J0 User Capacity: 500,107,862,016 bytes [500 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Form Factor: 2.5 inches Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ATA8-ACS T13/1699-D revision 6 SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s) Local Time is: Mon Oct 26 15:33:25 2015 CUT SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM level is: 128 (minimum power consumption without standby) Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x05) Offline data collection activity was aborted by an interrupting command from host. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 45) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 101) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 100 100 062 Pre-fail Always - 0 2 Throughput_Performance 0x0005 158 158 040 Pre-fail Offline - 105 3 Spin_Up_Time 0x0007 158 158 033 Pre-fail Always - 1 4 Start_Stop_Count 0x0012 097 097 000 Old_age Always - 5334 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0 8 Seek_Time_Performance 0x0005 100 100 040 Pre-fail Offline - 0 9 Power_On_Hours 0x0012 098 098 000 Old_age Always - 882 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 173 191 G-Sense_Error_Rate 0x000a 100 100 000 Old_age Always - 1 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 11 193 Load_Cycle_Count 0x0012 096 096 000 Old_age Always - 41201 194 Temperature_Celsius 0x0002 193 193 000 Old_age Always - 31 (Min/Max 18/48) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0 223 Load_Retry_Count 0x000a 100 100 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 881 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) SCT Support Level: 1 Device State: Active (0) Current Temperature: 31 Celsius Power Cycle Min/Max Temperature: 18/32 Celsius Lifetime Min/Max Temperature: 18/48 Celsius Lifetime Average Temperature: 30 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -40/65 Celsius Temperature History Size (Index): 128 (39) Index Estimated Time Temperature Celsius 40 2015-10-26 13:26 29 ********** 41 2015-10-26 13:27 30 *********** ... ..( 14 skipped). .. *********** 56 2015-10-26 13:42 30 *********** 57 2015-10-26 13:43 29 ********** 58 2015-10-26 13:44 30 *********** ... ..( 6 skipped). .. *********** 65 2015-10-26 13:51 30 *********** 66 2015-10-26 13:52 31 ************ ... ..( 23 skipped). .. ************ 90 2015-10-26 14:16 31 ************ 91 2015-10-26 14:17 32 ************* ... ..( 4 skipped). .. ************* 96 2015-10-26 14:22 32 ************* 97 2015-10-26 14:23 31 ************ 98 2015-10-26 14:24 31 ************ 99 2015-10-26 14:25 32 ************* ... ..( 2 skipped). .. ************* 102 2015-10-26 14:28 32 ************* 103 2015-10-26 14:29 31 ************ 104 2015-10-26 14:30 32 ************* 105 2015-10-26 14:31 31 ************ ... ..( 23 skipped). .. ************ 1 2015-10-26 14:55 31 ************ 2 2015-10-26 14:56 32 ************* 3 2015-10-26 14:57 31 ************ 4 2015-10-26 14:58 31 ************ 5 2015-10-26 14:59 31 ************ 6 2015-10-26 15:00 32 ************* ... ..( 2 skipped). .. ************* 9 2015-10-26 15:03 32 ************* 10 2015-10-26 15:04 31 ************ 11 2015-10-26 15:05 31 ************ 12 2015-10-26 15:06 32 ************* 13 2015-10-26 15:07 31 ************ ... ..( 7 skipped). .. ************ 21 2015-10-26 15:15 31 ************ 22 2015-10-26 15:16 32 ************* 23 2015-10-26 15:17 31 ************ ... ..( 15 skipped). .. ************ 39 2015-10-26 15:33 31 ************
------------------------------------------------------------------------------
_______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database