This is a repost of the entry for the TRION-100. The drivedb.h entry is
unchanged, but I originally omitted to include the smartctl -x
information, this is now included.

Here is the drivedb.h entry for the OCZ TRION 100 drive:


{
    "OCZ TRION",
    "OCZ-TRION100", // tested with Trion 100
    "",
    "",
    "-v 167,raw48,SSD_Protect_Mode "
    "-v 168,raw48,SATA_PHY_Error_Count "
    "-v 169,raw48,Bad_Block_Count "
    "-v 173,raw48,Erase_Count "
    "-v 192,raw48,Unexpect_Power_Loss_Ct "
}


Here is the smartctl -x output:

smartctl 6.3 2014-07-26 r3976 [x86_64-linux-4.0.5-gentoo] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     OCZ-TRION100
Serial Number:    75VB50BWKMGX
LU WWN Device Id: 5 e83a97 20027c413
Firmware Version: SAFM11.2
User Capacity:    960,197,124,096 bytes [960 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Form Factor:      2.5 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-2 (minor revision not indicated)
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Thu Oct 22 08:13:22 2015 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM level is:     254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00)    Offline data collection activity
                    was never started.
                    Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0)    The previous self-test
routine completed
                    without error or no self-test has ever
                    been run.
Total time to complete Offline
data collection:         (   30) seconds.
Offline data collection
capabilities:              (0x79) SMART execute Offline immediate.
                    No Auto Offline data collection support.
                    Suspend Offline collection upon new
                    command.
                    Offline surface scan supported.
                    Self-test supported.
                    Conveyance Self-test supported.
                    Selective Self-test supported.
SMART capabilities:            (0x0003)    Saves SMART data before entering
                    power-saving mode.
                    Supports SMART auto save timer.
Error logging capability:        (0x01)    Error logging supported.
                    General Purpose Logging supported.
Short self-test routine
recommended polling time:      (   1) minutes.
Extended self-test routine
recommended polling time:      (   2) minutes.
Conveyance self-test routine
recommended polling time:      (   3) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  9 Power_On_Hours          -O--C-   100   100   000    -    20
 12 Power_Cycle_Count       -O--C-   100   100   000    -    14
167 Unknown_Attribute       -O---K   100   100   000    -    0
168 Unknown_Attribute       -O--C-   100   100   000    -    0
169 Unknown_Attribute       PO----   100   100   010    -    0
173 Unknown_Attribute       -O--C-   200   200   000    -    0
192 Power-Off_Retract_Count -O--C-   100   100   000    -    1
194 Temperature_Celsius     PO---K   076   050   030    -    24 (Min/Max
23/50)
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x02           SL  R/O     51  Comprehensive SMART error log
0x03       GPL     R/O     64  Ext. Comprehensive SMART error log
0x04       GPL,SL  R/O      8  Device Statistics log
0x06           SL  R/O      1  SMART self-test log
0x07       GPL     R/O      1  Extended self-test log
0x09           SL  R/W      1  Selective self-test log
0x10       GPL     R/O      1  NCQ Command Error log
0x11       GPL     R/O      1  SATA Phy Event Counters
0x30       GPL,SL  R/O      9  IDENTIFY DEVICE data log
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xe0       GPL,SL  R/W      1  SCT Command/Status
0xe1       GPL,SL  R/W      1  SCT Data Transfer

SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
No Errors Logged

SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Commands not supported

Device Statistics (GP Log 0x04)
Page Offset Size         Value  Description
  1  =====  =                =  == General Statistics (rev 2) ==
  1  0x008  4               14  Lifetime Power-On Resets
  1  0x010  4               20  Power-on Hours
  1  0x018  6       4036191501  Logical Sectors Written
  1  0x020  6        181241545  Number of Write Commands
  1  0x028  6       1969844118  Logical Sectors Read
  1  0x030  6        166355863  Number of Read Commands
  1  0x038  6         72571253  Date and Time TimeStamp
  4  =====  =                =  == General Errors Statistics (rev 1) ==
  4  0x008  4                0  Number of Reported Uncorrectable Errors
  4  0x010  4                0  Resets Between Cmd Acceptance and Completion
  5  =====  =                =  == Temperature Statistics (rev 1) ==
  5  0x008  1               32  Current Temperature
  5  0x010  1               32  Average Short Term Temperature
  5  0x018  1               32  Average Long Term Temperature
  5  0x020  1               50  Highest Temperature
  5  0x028  1                5  Lowest Temperature
  5  0x030  1               50  Highest Average Short Term Temperature
  5  0x038  1               16  Lowest Average Short Term Temperature
  5  0x040  1               50  Highest Average Long Term Temperature
  5  0x048  1               16  Lowest Average Long Term Temperature
  5  0x050  4                0  Time in Over-Temperature
  5  0x058  1               50  Specified Maximum Operating Temperature
  5  0x060  4                0  Time in Under-Temperature
  5  0x068  1                5  Specified Minimum Operating Temperature
  6  =====  =                =  == Transport Statistics (rev 1) ==
  6  0x008  4            19812  Number of Hardware Resets
  6  0x018  4                0  Number of Interface CRC Errors
  7  =====  =                =  == Solid State Device Statistics (rev 1) ==
  7  0x008  1                0  Percentage Used Endurance Indicator

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x0001  2            0  Command failed due to ICRC error
0x0003  2            0  R_ERR response for device-to-host data FIS
0x0004  2            0  R_ERR response for host-to-device data FIS
0x0006  2            0  R_ERR response for device-to-host non-data FIS
0x0007  2            0  R_ERR response for host-to-device non-data FIS
0x0008  2            0  Device-to-host non-data FIS retries
0x0009  4          317  Transition from drive PhyRdy to drive PhyNRdy
0x000a  4           41  Device-to-host register FISes sent due to a COMRESET
0x000f  2            0  R_ERR response for host-to-device data FIS, CRC
0x0010  2            0  R_ERR response for host-to-device data FIS, non-CRC
0x0012  2            0  R_ERR response for host-to-device non-data FIS, CRC
0x0013  2            0  R_ERR response for host-to-device non-data FIS,
non-CRC


--

Paul Grabinar
Principal Software Engineer

OCZ Storage Solutions Limited
25B-25C Western Avenue
Milton Park
Abingdon
Oxfordshire
OX14 4SH

Registered in England no 7806324
Registered Address:  As Above

Tel: +44 (0) 1235 824900

Fax: +44 (0) 1235 821141

Email: pgrabi...@ocz.com

Subsidiary of OCZ Storage Solutions http://www.ocz.com


CONFIDENTIAL COMMUNICATION:  This communication including any attached file(s) 
is CONFIDENTIAL, intended only for the named recipient (s) above and contains 
trade secrets or other information that is exempt from disclosure under 
applicable law.  Any use, dissemination, distribution or copying of this 
communication and any file attachments by anyone other than the named recipient 
(s) is strictly prohibited. If you have received this communication in error, 
please immediately notify us by reply electronic mail and permanently delete 
the original transmission and any attachments from your computer system and any 
copies of this message and file attachments. Thank you.

------------------------------------------------------------------------------
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to