Please find attached a submission for the disk CT250BX100SSD1
smartctl 6.3 2014-07-26 r3976 [i686-w64-mingw32-vista-sp2] (sf-6.3-1) Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION === Device Model: CT250BX100SSD1 Firmware Version: MU02 User Capacity: 250,059,350,016 bytes [250 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Wed Aug 19 22:54:38 2015 GMTDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x02) Offline data collection activity was completed without error. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x71) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0002) Does not save SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 10) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x0035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x0000 100 100 000 Old_age Offline - 0 5 Reallocated_Sector_Ct 0x0000 100 100 000 Old_age Offline - 0 9 Power_On_Hours 0x0000 100 100 000 Old_age Offline - 0 12 Power_Cycle_Count 0x0000 100 100 000 Old_age Offline - 6 160 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0 161 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 66 163 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 25 164 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 1205 165 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 3 166 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 1 167 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 1 168 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 2000 169 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 100 175 Program_Fail_Count_Chip 0x0000 100 100 000 Old_age Offline - 0 176 Erase_Fail_Count_Chip 0x0000 100 100 000 Old_age Offline - 0 177 Wear_Leveling_Count 0x0000 100 100 000 Old_age Offline - 0 178 Used_Rsvd_Blk_Cnt_Chip 0x0000 100 100 000 Old_age Offline - 0 181 Program_Fail_Cnt_Total 0x0000 100 100 000 Old_age Offline - 0 182 Erase_Fail_Count_Total 0x0000 100 100 000 Old_age Offline - 0 192 Power-Off_Retract_Count 0x0000 100 100 000 Old_age Offline - 1 194 Temperature_Celsius 0x0000 100 100 000 Old_age Offline - 36 195 Hardware_ECC_Recovered 0x0000 100 100 000 Old_age Offline - 11 196 Reallocated_Event_Count 0x0000 100 100 000 Old_age Offline - 0 197 Current_Pending_Sector 0x0000 100 100 000 Old_age Offline - 0 198 Offline_Uncorrectable 0x0000 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0000 100 100 000 Old_age Offline - 0 232 Available_Reservd_Space 0x0000 100 100 000 Old_age Offline - 100 241 Total_LBAs_Written 0x0000 100 100 000 Old_age Offline - 7450 242 Total_LBAs_Read 0x0000 100 100 000 Old_age Offline - 4300 245 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 9640 SMART Error Log not supported SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 0 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
_______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database