Yo Smartmontools!
Attached drive details.
RGDS
GARY
---------------------------------------------------------------------------
Gary E. Miller Rellim 109 NW Wilmington Ave., Suite E, Bend, OR 97701
g...@rellim.com Tel:+1(541)382-8588
smartctl 6.3 2014-07-26 r3976 [x86_64-linux-3.17.7-gentoo] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: ST240HM000-1G5152
Serial Number: Z4N01153
LU WWN Device Id: 5 000c50 02ff2a839
Firmware Version: C675
User Capacity: 240,057,409,536 bytes [240 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 1.5 Gb/s)
Local Time is: Tue Jan 13 11:40:20 2015 PST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART Status command failed
Please get assistance from http://smartmontools.sourceforge.net/
Register values returned from SMART Status command are:
ERR=0x00, SC=0x00, LL=0x00, LM=0x00, LH=0x00, DEV=0x00, STS=0x00
SMART Status not supported: Invalid ATA output register values
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 5) seconds.
Offline data collection
capabilities: (0x19) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0002) Does not save SMART data before
entering power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 38) minutes.
SMART Attributes Data Structure revision number: 0
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate -OSR-- 001 001 006 NOW 35582
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
9 Power_On_Hours -O--CK 098 098 000 - 2182
12 Power_Cycle_Count -O--CK 100 100 020 - 4
171 Unknown_Attribute -O--CK 100 100 000 - 0
172 Unknown_Attribute -O--CK 100 100 000 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 000 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 029 022 000 - 29 (Min/Max 22/58)
201 Unknown_SSD_Attribute -O--CK 100 100 000 - 0
204 Soft_ECC_Correction -O--CK 001 001 000 - 35582
231 Temperature_Celsius PO--C- 078 078 010 - 23
234 Unknown_Attribute -O--CK 100 100 000 - 313440
241 Total_LBAs_Written -O--CK 100 100 000 - 2877
242 Total_LBAs_Read -O--CK 100 100 000 - 3130
250 Read_Error_Retry_Rate -O--CK 100 100 000 - 35582
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x07 GPL,SL R/O 2 Extended self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa8 GPL VS 1041 Device vendor specific log
0xa8 SL VS 255 Device vendor specific log
0xb7 GPL,SL VS 4 Device vendor specific log
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 56 (device log contains only the most recent 20 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 56 [15] occurred at disk power-on lifetime: 1809 hours (75 days + 9 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 00 00 00 00 00 00 00 e0 08 Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d5 00 01 00 00 00 c2 4f 01 00 08 25d+15:04:26.054 SMART READ LOG
b0 00 d5 00 01 00 00 00 c2 4f 06 00 08 25d+15:04:26.054 SMART READ LOG
b0 00 d5 00 01 00 00 00 c2 4f 00 00 08 25d+15:04:26.054 SMART READ LOG
b0 00 db 00 f8 00 00 00 c2 4f 00 00 08 25d+15:04:26.044 SMART EN/DISABLE
AUTO OFFLINE [NS (SFF-8035i)]
b0 00 d1 00 01 00 00 00 c2 4f 01 00 08 25d+15:04:26.044 SMART READ ATTRIBUTE
THRESHOLDS [OBS-4]
Error 55 [14] occurred at disk power-on lifetime: 1809 hours (75 days + 9 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 00 00 00 00 00 00 00 e0 08 Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d5 00 01 00 00 00 c2 4f 06 00 08 25d+15:04:26.054 SMART READ LOG
b0 00 d5 00 01 00 00 00 c2 4f 00 00 08 25d+15:04:26.054 SMART READ LOG
b0 00 db 00 f8 00 00 00 c2 4f 00 00 08 25d+15:04:26.044 SMART EN/DISABLE
AUTO OFFLINE [NS (SFF-8035i)]
b0 00 d1 00 01 00 00 00 c2 4f 01 00 08 25d+15:04:26.044 SMART READ ATTRIBUTE
THRESHOLDS [OBS-4]
ea 00 00 00 00 00 00 00 00 00 00 a0 08 25d+15:04:26.044 FLUSH CACHE EXT
Error 54 [13] occurred at disk power-on lifetime: 1809 hours (75 days + 9 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 00 00 00 00 00 00 00 e0 08 Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 db 00 f8 00 00 00 c2 4f 00 00 08 25d+15:04:26.044 SMART EN/DISABLE
AUTO OFFLINE [NS (SFF-8035i)]
b0 00 d1 00 01 00 00 00 c2 4f 01 00 08 25d+15:04:26.044 SMART READ ATTRIBUTE
THRESHOLDS [OBS-4]
ea 00 00 00 00 00 00 00 00 00 00 a0 08 25d+15:04:26.044 FLUSH CACHE EXT
b0 00 d0 00 01 00 00 00 c2 4f 00 00 08 25d+15:04:26.034 SMART READ DATA
61 00 08 00 00 00 00 11 8e 31 68 40 08 25d+15:04:26.034 WRITE FPDMA QUEUED
Error 53 [12] occurred at disk power-on lifetime: 1809 hours (75 days + 9 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 00 00 00 00 00 00 00 e0 08 Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d2 00 f1 00 00 00 c2 4f 00 00 08 25d+15:04:26.004 SMART ENABLE/DISABLE
ATTRIBUTE AUTOSAVE
ea 00 00 00 00 00 00 00 00 00 00 a0 08 25d+15:04:25.994 FLUSH CACHE EXT
b0 00 d8 00 00 00 00 00 c2 4f 01 00 08 25d+15:04:25.994 SMART ENABLE
OPERATIONS
61 00 08 00 00 00 00 11 8e 31 08 40 08 25d+15:04:25.994 WRITE FPDMA QUEUED
ea 00 00 00 00 00 00 00 00 00 00 a0 08 25d+15:04:25.984 FLUSH CACHE EXT
Error 52 [11] occurred at disk power-on lifetime: 1774 hours (73 days + 22
hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 00 00 00 00 00 00 00 e0 08 Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d5 00 01 00 00 00 c2 4f 01 00 08 24d+03:32:21.324 SMART READ LOG
61 00 10 00 10 00 00 03 e9 70 08 40 08 24d+03:32:21.324 WRITE FPDMA QUEUED
61 00 48 00 08 00 00 11 8a f5 88 40 08 24d+03:32:21.324 WRITE FPDMA QUEUED
60 02 00 00 00 00 00 09 a1 25 e0 40 08 24d+03:32:21.324 READ FPDMA QUEUED
b0 00 d5 00 01 00 00 00 c2 4f 06 00 08 24d+03:32:21.314 SMART READ LOG
Error 51 [10] occurred at disk power-on lifetime: 1774 hours (73 days + 22
hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 00 00 00 00 00 00 00 e0 08 Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d5 00 01 00 00 00 c2 4f 06 00 08 24d+03:32:21.314 SMART READ LOG
ea 00 00 00 00 00 00 00 00 00 00 a0 08 24d+03:32:21.304 FLUSH CACHE EXT
b0 00 d5 00 01 00 00 00 c2 4f 00 00 08 24d+03:32:21.304 SMART READ LOG
61 00 08 00 00 00 00 11 8a f5 80 40 08 24d+03:32:21.304 WRITE FPDMA QUEUED
ea 00 00 00 00 00 00 00 00 00 00 a0 08 24d+03:32:21.304 FLUSH CACHE EXT
Error 50 [9] occurred at disk power-on lifetime: 1774 hours (73 days + 22 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 00 00 00 00 c2 4f 00 e0 08 Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 db 00 f8 00 00 00 c2 4f 00 00 08 24d+03:32:21.294 SMART EN/DISABLE
AUTO OFFLINE [NS (SFF-8035i)]
b0 00 d1 00 01 00 00 00 c2 4f 01 00 08 24d+03:32:21.294 SMART READ ATTRIBUTE
THRESHOLDS [OBS-4]
b0 00 d0 00 01 00 00 00 c2 4f 00 00 08 24d+03:32:21.294 SMART READ DATA
b0 00 da 00 00 00 00 00 c2 4f 00 00 08 24d+03:32:21.284 SMART RETURN STATUS
b0 00 d2 00 f1 00 00 00 c2 4f 00 00 08 24d+03:32:21.274 SMART ENABLE/DISABLE
ATTRIBUTE AUTOSAVE
Error 49 [8] occurred at disk power-on lifetime: 1774 hours (73 days + 22 hours)
When the command that caused the error occurred, the device was active or
idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
04 -- 51 00 00 00 00 00 00 00 00 e0 08 Error: ABRT
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
b0 00 d2 00 f1 00 00 00 c2 4f 00 00 08 24d+03:32:21.274 SMART ENABLE/DISABLE
ATTRIBUTE AUTOSAVE
b0 00 d8 00 00 00 00 00 c2 4f 01 00 08 24d+03:32:21.274 SMART ENABLE
OPERATIONS
ec 00 00 00 00 00 00 00 00 00 00 00 08 24d+03:32:21.264 IDENTIFY DEVICE
61 00 68 00 00 00 00 11 8a f5 18 40 08 24d+03:32:21.204 WRITE FPDMA QUEUED
61 00 08 00 00 00 00 02 28 e8 a8 40 08 24d+03:32:21.194 WRITE FPDMA QUEUED
Warning! SMART Extended Self-test Log Structure (1/2) error: invalid SMART
checksum.
SMART Extended Self-test Log Version: 1 (2 sectors)
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 2182 -
# 2 Short offline Completed without error 00% 2172 -
# 3 Short offline Completed without error 00% 2148 -
# 4 Short offline Completed without error 00% 2124 -
# 5 Extended offline Completed without error 00% 2101 -
# 6 Short offline Completed without error 00% 2100 -
# 7 Short offline Completed without error 00% 2076 -
# 8 Short offline Completed without error 00% 2052 -
# 9 Short offline Completed without error 00% 2028 -
#10 Short offline Completed without error 00% 2004 -
#11 Short offline Completed without error 00% 1980 -
#12 Short offline Completed without error 00% 1956 -
#13 Extended offline Completed without error 00% 1933 -
#14 Short offline Completed without error 00% 1932 -
#15 Short offline Completed without error 00% 1908 -
#16 Short offline Completed without error 00% 1884 -
#17 Short offline Completed without error 00% 1860 -
#18 Short offline Completed without error 00% 1836 -
#19 Short offline Completed without error 00% 1812 -
#20 Short offline Completed without error 00% 1788 -
#21 Extended offline Completed without error 00% 1765 -
#22 Short offline Completed without error 00% 1764 -
#23 Short offline Completed without error 00% 1740 -
#24 Short offline Completed without error 00% 1716 -
#25 Short offline Completed without error 00% 1692 -
Selective Self-tests/Logging not supported
SCT Commands not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Description
1 ===== = = == General Statistics (rev 2) ==
1 0x008 4 4 Lifetime Power-On Resets
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 48 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
------------------------------------------------------------------------------
New Year. New Location. New Benefits. New Data Center in Ashburn, VA.
GigeNET is offering a free month of service with a new server in Ashburn.
Choose from 2 high performing configs, both with 100TB of bandwidth.
Higher redundancy.Lower latency.Increased capacity.Completely compliant.
http://p.sf.net/sfu/gigenet
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database