smartctl 6.3 2014-07-26 r3976 [FreeBSD 10.0-RELEASE-p7 amd64] (local build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: INTEL SSDMCEAW240A4
Firmware Version: DC33
User Capacity: 240,057,409,536 bytes [240 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Tue Dec 23 13:38:02 2014 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 5860) seconds.
Offline data collection
capabilities: (0x7f) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Abort Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 48) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x0025) SCT Status supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct -O--CK 100 100 000 - 0
9 Power_On_Hours -O--CK 100 100 000 - 1155 (93 138 0)
12 Power_Cycle_Count -O--CK 100 100 000 - 7
170 Unknown_Attribute PO--CK 100 100 010 - 0
171 Unknown_Attribute -O--CK 100 100 000 - 0
172 Unknown_Attribute -O--CK 100 100 000 - 0
174 Unknown_Attribute -O--CK 100 100 000 - 0
183 Runtime_Bad_Block -O--CK 100 100 000 - 9
184 End-to-End_Error PO--CK 100 100 090 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 035 067 000 - 35 (Min/Max 23/67)
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
225 Unknown_SSD_Attribute -O--CK 100 100 000 - 2058
226 Unknown_SSD_Attribute -O--CK 100 100 000 - 65535
227 Unknown_SSD_Attribute -O--CK 100 100 000 - 53
228 Power-off_Retract_Count -O--CK 100 100 000 - 65535
232 Available_Reservd_Space PO--CK 100 100 010 - 0
233 Media_Wearout_Indicator -O--CK 100 100 000 - 0
241 Total_LBAs_Written -O--CK 100 100 000 - 2058
242 Total_LBAs_Read -O--CK 100 100 000 - 206
249 Unknown_Attribute -O--CK 100 100 000 - 606
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x04 GPL,SL R/O 1 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters
0x30 GPL,SL R/O 16 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xb7 GPL,SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log not supported
SMART Extended Self-test Log Version: 0 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 1155 -
# 2 Offline Interrupted (host reset) 10% 851 -
# 3 Offline Interrupted (host reset) 10% 851 -
# 4 Extended offline Completed without error 00% 38 -
# 5 Conveyance offline Completed without error 00% 37 -
# 6 Short offline Completed without error 00% 37 -
# 7 Offline Interrupted (host reset) 10% 37 -
# 8 Extended offline Completed without error 00% 20 -
# 9 Conveyance offline Completed without error 00% 19 -
#10 Short offline Completed without error 00% 19 -
#11 Offline Interrupted (host reset) 10% 2 -
#12 Offline Interrupted (host reset) 10% 0 -
#13 Offline Interrupted (host reset) 10% 0 -
#14 Offline Interrupted (host reset) 10% 0 -
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been
run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 0 (0x0000)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 34 Celsius
Power Cycle Min/Max Temperature: 23/67 Celsius
Lifetime Min/Max Temperature: 23/67 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 0 (Unknown, should be 2)
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/ 0 Celsius
Min/Max Temperature Limit: 0/ 0 Celsius
Temperature History Size (Index): 0 (17)
Temperature History is empty
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Description
1 ===== = = == General Statistics (rev 2) ==
1 0x008 4 20 Lifetime Power-On Resets
1 0x010 4 1166 Power-on Hours
1 0x018 6 1665953702 Logical Sectors Written
1 0x028 6 1909326525 Logical Sectors Read
4 ===== = = == General Errors Statistics (rev 1) ==
4 0x008 4 0 Number of Reported Uncorrectable Errors
4 0x010 4 119 Resets Between Cmd Acceptance and Completion
5 ===== = = == Temperature Statistics (rev 1) ==
5 0x008 1 34 Current Temperature
5 0x010 1 - Average Short Term Temperature
5 0x018 1 - Average Long Term Temperature
5 0x020 1 67 Highest Temperature
5 0x028 1 39 Lowest Temperature
5 0x030 1 - Highest Average Short Term Temperature
5 0x038 1 - Lowest Average Short Term Temperature
5 0x040 1 - Highest Average Long Term Temperature
5 0x048 1 - Lowest Average Long Term Temperature
5 0x050 4 0 Time in Over-Temperature
5 0x058 1 70 Specified Maximum Operating Temperature
5 0x060 4 0 Time in Under-Temperature
5 0x068 1 0 Specified Minimum Operating Temperature
6 ===== = = == Transport Statistics (rev 1) ==
6 0x008 4 119 Number of Hardware Resets
6 0x010 4 12 Number of ASR Events
6 0x018 4 0 Number of Interface CRC Errors
7 ===== = = == Solid State Device Statistics (rev 1) ==
7 0x008 1 0 Percentage Used Endurance Indicator
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 9 Device-to-host register FISes sent due to a COMRESET
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
0x0002 2 0 R_ERR response for data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
------------------------------------------------------------------------------
Dive into the World of Parallel Programming! The Go Parallel Website,
sponsored by Intel and developed in partnership with Slashdot Media, is your
hub for all things parallel software development, from weekly thought
leadership blogs to news, videos, case studies, tutorials and more. Take a
look and join the conversation now. http://goparallel.sourceforge.net
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database