Please add the ST6000NM0024-1HT17Z device to your database.
And thanks for the great tool and keep up the good work. -- http://www.linum.com mailto:claas.hilbre...@linum.com Linum Software GmbH, Langer Wall 5, 37574 Einbeck, Germany Tel: +49-5561-926730 Fax: +49-5561-926750Handelsregister Amtsgericht Göttingen HRB 131128 / Geschäftsführer Claas-Jörg Hilbrecht
smartctl 6.4 2014-09-29 r3990 [x86_64-linux-3.2.0-4-amd64] (local build) Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: ST6000NM0024-1HT17Z Firmware Version: SN02 User Capacity: 6.001.175.126.016 bytes [6,00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Form Factor: 3.5 inches Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-3 (minor revision not indicated) SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Tue Dec 9 22:43:23 2014 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 89) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 636) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x50bd) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-- 076 063 044 - 45546059 3 Spin_Up_Time PO---- 099 099 000 - 0 4 Start_Stop_Count -O--CK 100 100 020 - 1 5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0 7 Seek_Error_Rate POSR-- 063 060 030 - 2604196 9 Power_On_Hours -O--CK 100 100 000 - 7 10 Spin_Retry_Count PO--C- 100 100 097 - 0 12 Power_Cycle_Count -O--CK 100 100 020 - 1 184 End-to-End_Error -O--CK 100 100 099 - 0 187 Reported_Uncorrect -O--CK 100 100 000 - 0 188 Command_Timeout -O--CK 100 100 000 - 0 189 High_Fly_Writes -O-RCK 100 100 000 - 0 190 Airflow_Temperature_Cel -O---K 057 054 045 - 43 (Min/Max 18/46) 191 G-Sense_Error_Rate -O--CK 100 100 000 - 0 192 Power-Off_Retract_Count -O--CK 100 100 000 - 0 193 Load_Cycle_Count -O--CK 100 100 000 - 4 194 Temperature_Celsius -O---K 043 046 000 - 43 (0 18 0 0 0) 195 Hardware_ECC_Recovered -O-RC- 069 042 000 - 45546059 197 Current_Pending_Sector -O--C- 100 100 000 - 0 198 Offline_Uncorrectable ----C- 100 100 000 - 0 199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 5 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x08 GPL,SL R/O 2 Power Conditions log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters 0x13 GPL R/O 1 SATA NCQ Send and Receive log 0x15 GPL - 1 Reserved for Serial ATA 0x21 GPL R/O 1 Write stream error log 0x22 GPL R/O 1 Read stream error log 0x24 GPL R/O 512 Current Device Internal Status Data log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa1 GPL,SL VS 20 Device vendor specific log 0xa2 GPL VS 8160 Device vendor specific log 0xa8-0xa9 GPL,SL VS 136 Device vendor specific log 0xab GPL VS 1 Device vendor specific log 0xb0 GPL VS 8982 Device vendor specific log 0xbe-0xbf GPL VS 65535 Device vendor specific log 0xc1 GPL,SL VS 10 Device vendor specific log 0xc3 GPL,SL VS 8 Device vendor specific log 0xc7 GPL,SL VS 1 Device vendor specific log 0xd1 GPL,SL VS 8 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (5 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 6 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 522 (0x020a) SCT Support Level: 1 Device State: Active (0) Current Temperature: 43 Celsius Power Cycle Min/Max Temperature: 18/45 Celsius Lifetime Min/Max Temperature: 18/45 Celsius Under/Over Temperature Limit Count: 0/8 SCT Temperature History Version: 2 Temperature Sampling Period: 3 minutes Temperature Logging Interval: 59 minutes Min/Max recommended Temperature: 0/ 0 Celsius Min/Max Temperature Limit: 0/ 0 Celsius Temperature History Size (Index): 128 (9) Index Estimated Time Temperature Celsius 10 2014-12-04 17:17 ? - ... ..(116 skipped). .. - 127 2014-12-09 12:20 ? - 0 2014-12-09 13:19 30 *********** 1 2014-12-09 14:18 ? - 2 2014-12-09 15:17 18 - 3 2014-12-09 16:16 41 ********************** 4 2014-12-09 17:15 45 ************************** 5 2014-12-09 18:14 45 ************************** 6 2014-12-09 19:13 44 ************************* ... ..( 2 skipped). .. ************************* 9 2014-12-09 22:10 44 ************************* SCT Error Recovery Control: Read: 100 (10,0 seconds) Write: 100 (10,0 seconds) Device Statistics (GP Log 0x04) Page Offset Size Value Description 1 ===== = = == General Statistics (rev 2) == 1 0x008 4 1 Lifetime Power-On Resets 1 0x010 4 7 Power-on Hours 1 0x018 6 3139271 Logical Sectors Written 1 0x020 6 13862 Number of Write Commands 1 0x028 6 8751264111 Logical Sectors Read 1 0x030 6 15712508 Number of Read Commands 1 0x038 6 - Date and Time TimeStamp 3 ===== = = == Rotating Media Statistics (rev 1) == 3 0x008 4 7 Spindle Motor Power-on Hours 3 0x010 4 7 Head Flying Hours 3 0x018 4 4 Head Load Events 3 0x020 4 0 Number of Reallocated Logical Sectors 3 0x028 4 0 Read Recovery Attempts 3 0x030 4 0 Number of Mechanical Start Failures 4 ===== = = == General Errors Statistics (rev 1) == 4 0x008 4 0 Number of Reported Uncorrectable Errors 4 0x010 4 0 Resets Between Cmd Acceptance and Completion 5 ===== = = == Temperature Statistics (rev 1) == 5 0x008 1 43~ Current Temperature 5 0x010 1 1~ Average Short Term Temperature 5 0x018 1 0~ Average Long Term Temperature 5 0x020 1 42~ Highest Temperature 5 0x028 1 18~ Lowest Temperature 5 0x038 1 1~ Lowest Average Short Term Temperature 5 0x048 1 0~ Lowest Average Long Term Temperature 5 0x050 4 0 Time in Over-Temperature 5 0x058 1 55 Specified Maximum Operating Temperature 5 0x060 4 0 Time in Under-Temperature 5 0x068 1 13 Specified Minimum Operating Temperature 6 ===== = = == Transport Statistics (rev 1) == |_ ~ normalized value SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x000a 2 10 Device-to-host register FISes sent due to a COMRESET 0x0001 2 0 Command failed due to ICRC error 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS
------------------------------------------------------------------------------ Download BIRT iHub F-Type - The Free Enterprise-Grade BIRT Server from Actuate! Instantly Supercharge Your Business Reports and Dashboards with Interactivity, Sharing, Native Excel Exports, App Integration & more Get technology previously reserved for billion-dollar corporations, FREE http://pubads.g.doubleclick.net/gampad/clk?id=164703151&iu=/4140/ostg.clktrk
_______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database