Hi List,
output of smartctl -x /dev/hdd for a "TrekStorDS maxi pace 3.0" (USB
3.0, 3 TB, from Windows 7) is attached.
I also tried to use -d sat and -d usbsunplus but that resulted in
"Smartctl open device: /dev/hdd [SAT / USB Sunplus] failed: Invalid
argument".
I hope this helps to improve smartmontools =)
Regards,
Jan
smartctl 6.3 2014-07-26 r3976 [i686-w64-mingw32-win7(64)-sp1] (sf-6.3-1)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: TrekStorDS maxi pace 3.0
Serial Number: A3200000000000000103
Firmware Version: 0
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: [No Information Found]
Local Time is: Tue Sep 09 18:41:01 2014 MS
SMART support is: Available - device has SMART capability.
Enabled status cached by OS, trying SMART RETURN STATUS cmd.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Unavailable
Write cache is: Unavailable
ATA Security is: Unavailable
Wt Cache Reorder: Unavailable
Read SMART Thresholds failed: Function not implemented
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0xff) Offline data collection activity
is in a Vendor Specific state.
Auto Offline Data Collection: Enabled.
Total time to complete Offline
data collection: (65535) seconds.
Offline data collection
capabilities: (0x00) Offline data collection not
supported.
SMART capabilities: (0x0000) Automatic saving of SMART data
is not implemented.
Error logging capability: (0x00) Error logging NOT supported.
No General Purpose Logging support.
SMART Attributes Data Structure revision number: 0
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
72 Unknown_Attribute ------+ 000 114 --- - 115450398663680
115 Unknown_Attribute ------+ 000 086 --- - 128644672417536
109 Unknown_Attribute ------+ 000 050 --- - 32768
58 Unknown_Attribute --SR--+ 250 255 --- - 140780738093311
255 Unknown_Attribute POSRCK+ 055 075 --- - 238594022735873
17 Unknown_Attribute -O-R--+ 248 255 --- - 175943344419071
255 Unknown_Attribute POSRCK+ 139 000 --- - 1099511144453
255 Unknown_Attribute POSRCK+ 221 017 --- - 216603790180362
200 Multi_Zone_Error_Rate ---RC-+ 248 255 --- - 2199023255807
151 Unknown_Attribute PO----+ 248 255 --- - 175943344484607
255 Unknown_Attribute POSRCK+ 000 080 --- - 125344325566464
200 Multi_Zone_Error_Rate ---RC-+ 248 255 --- - 255
17 Unknown_Attribute -O-R--+ 248 255 --- - 140780738128127
255 Unknown_Attribute POSRCK+ 226 017 --- - 1099511136266
63 Unknown_Attribute --SR--+ 250 255 --- - 140790006288639
255 Unknown_Attribute POSRCK+ 000 000 --- - 2199023255552
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
Read SMART Log Directory failed: Function not implemented
ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: Function not implemented
Read GP Log Directory failed
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log not supported
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test Log not supported
Selective Self-tests/Logging not supported
SCT Commands not supported
Device Statistics (GP Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11) not supported
------------------------------------------------------------------------------
Want excitement?
Manually upgrade your production database.
When you want reliability, choose Perforce
Perforce version control. Predictably reliable.
http://pubads.g.doubleclick.net/gampad/clk?id=157508191&iu=/4140/ostg.clktrk
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database