smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.11.10-17-desktop] (SUSE RPM) Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION === Device Model: SAMSUNG HD252KJ Serial Number: S0NJJDSP900508 LU WWN Device Id: 5 0000f0 0db900508 Firmware Version: CM100-11 User Capacity: 250.059.350.016 bytes [250 GB] Sector Size: 512 bytes logical/physical Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ATA8-ACS T13/1699-D revision 3b SATA Version is: SATA 2.5, 3.0 Gb/s Local Time is: Sun Aug 10 14:03:09 2014 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 5500) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 93) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-- 100 100 051 - 0 3 Spin_Up_Time POS--- 100 100 015 - 5504 4 Start_Stop_Count -O--CK 095 095 000 - 5594 5 Reallocated_Sector_Ct PO--CK 253 253 010 - 0 7 Seek_Error_Rate POSR-- 253 253 051 - 0 8 Seek_Time_Performance P-S--K 253 253 015 - 0 9 Power_On_Hours -O--CK 100 100 000 - 29770 10 Spin_Retry_Count PO--CK 253 253 051 - 0 11 Calibration_Retry_Count -O--C- 253 100 000 - 0 12 Power_Cycle_Count -O--CK 098 098 000 - 2899 13 Read_Soft_Error_Rate -OSR-- 100 100 000 - 1114351 187 Reported_Uncorrect -O--CK 253 253 000 - 65536 188 Command_Timeout -O--CK 100 100 000 - 2 190 Airflow_Temperature_Cel -O---K 070 058 000 - 30 194 Temperature_Celsius -O---K 148 112 000 - 30 195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 1114351 196 Reallocated_Event_Count -O--CK 253 253 000 - 0 197 Current_Pending_Sector -O--C- 253 253 000 - 0 198 Offline_Uncorrectable ----CK 253 253 000 - 0 199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0 200 Multi_Zone_Error_Rate -O-R-- 100 100 000 - 0 201 Soft_Read_Error_Rate -O-R-- 253 100 000 - 0 202 Data_Address_Mark_Errs -O--CK 253 253 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 2 Comprehensive SMART error log 0x03 GPL R/O 2 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (2 sectors) No Errors Logged SMART Extended Self-test Log (GP Log 0x07) not supported SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 29770 - # 2 Extended offline Completed without error 00% 28778 - # 3 Extended offline Completed without error 00% 26719 - # 4 Extended offline Completed without error 00% 19635 - # 5 Extended offline Completed without error 00% 17065 - # 6 Extended offline Completed without error 00% 17000 - # 7 Extended offline Completed without error 00% 16920 - # 8 Extended offline Completed without error 00% 16799 - # 9 Extended offline Completed without error 00% 16687 - #10 Extended offline Completed without error 00% 16602 - #11 Extended offline Completed without error 00% 16517 - #12 Extended offline Completed without error 00% 16431 - #13 Extended offline Interrupted (host reset) 10% 16360 - #14 Extended offline Completed without error 00% 16256 - #15 Extended offline Completed without error 00% 16138 - #16 Extended offline Completed without error 00% 16025 - #17 Extended offline Completed without error 00% 15869 - #18 Extended offline Completed without error 00% 15751 - #19 Extended offline Completed without error 00% 15625 - #20 Extended offline Completed without error 00% 15430 - #21 Short offline Completed without error 00% 15420 - SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 2 SCT Version (vendor specific): 256 (0x0100) SCT Support Level: 1 Device State: Active (0) Current Temperature: 30 Celsius Power Cycle Min/Max Temperature: 19/30 Celsius Lifetime Min/Max Temperature: 10/42 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: -4/72 Celsius Min/Max Temperature Limit: -9/77 Celsius Temperature History Size (Index): 128 (120) Index Estimated Time Temperature Celsius 121 2014-08-10 11:56 29 ********** ... ..(121 skipped). .. ********** 115 2014-08-10 13:58 29 ********** 116 2014-08-10 13:59 30 *********** ... ..( 2 skipped). .. *********** 119 2014-08-10 14:02 30 *********** 120 2014-08-10 14:03 29 ********** SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 5 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC 0x8001 2 0 Vendor specific
------------------------------------------------------------------------------
_______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database