Hi there,One of my USB drives isn't recognised by smartctl; I tried upgrading to the latest trunk source from svn & latest database. However it seems to work fine with -d sat.
I've attached a file containing the output requested in the FAQ. Thanks Joseph
bran:~# smartctl -t short /dev/sdb smartctl 6.3 2014-07-18 r3959 [i686-linux-3.2.0-4-686-pae] (local build) Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org /dev/sdb: Unknown USB bridge [0x0bc2:0x2320 (0x100)] Please specify device type with the -d option. Use smartctl -h to get a usage summary bran:~# smartctl -t short /dev/sdb -d sat smartctl 6.3 2014-07-18 r3959 [i686-linux-3.2.0-4-686-pae] (local build) Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org === START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION === Sending command: "Execute SMART Short self-test routine immediately in off-line mode". Drive command "Execute SMART Short self-test routine immediately in off-line mode" successful. Testing has begun. Please wait 2 minutes for test to complete. Test will complete after Sat Jul 19 15:51:26 2014 Use smartctl -X to abort test. bran:~# smartctl -x /dev/sdb -d sat smartctl 6.3 2014-07-18 r3959 [i686-linux-3.2.0-4-686-pae] (local build) Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Momentus SpinPoint M8 (AF) Device Model: ST1000LM024 HN-M101MBB Serial Number: S2ZPJ9BD258324 LU WWN Device Id: 5 0004cf 209ce294e Firmware Version: 2AR20002 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Form Factor: 2.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 6 SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s) Local Time is: Sat Jul 19 15:52:26 2014 BST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Disabled APM feature is: Disabled Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (12660) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 211) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 100 100 051 - 0 2 Throughput_Performance -OS--K 252 252 000 - 0 3 Spin_Up_Time PO---K 086 086 025 - 4455 4 Start_Stop_Count -O--CK 092 092 000 - 8947 5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0 7 Seek_Error_Rate -OSR-K 252 252 051 - 0 8 Seek_Time_Performance --S--K 252 252 015 - 0 9 Power_On_Hours -O--CK 100 100 000 - 1706 10 Spin_Retry_Count -O--CK 252 252 051 - 0 11 Calibration_Retry_Count -O--CK 100 100 000 - 3 12 Power_Cycle_Count -O--CK 100 100 000 - 14 191 G-Sense_Error_Rate -O---K 100 100 000 - 1 192 Power-Off_Retract_Count -O---K 252 252 000 - 0 194 Temperature_Celsius -O---- 061 061 000 - 39 (Min/Max 22/44) 195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0 196 Reallocated_Event_Count -O--CK 252 252 000 - 0 197 Current_Pending_Sector -O--CK 252 252 000 - 0 198 Offline_Uncorrectable ----CK 252 252 000 - 0 199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 0 200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 1 223 Load_Retry_Count -O--CK 100 100 000 - 3 225 Load_Cycle_Count -O--CK 096 096 000 - 42518 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 2 Comprehensive SMART error log 0x03 GPL R/O 2 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 2 Extended self-test log 0x08 GPL R/O 2 Power Conditions log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xc0-0xdf GPL,SL VS 16 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (2 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (2 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 1705 - SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Completed [00% left] (0-65535) 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 2 SCT Version (vendor specific): 256 (0x0100) SCT Support Level: 1 Device State: Active (0) Current Temperature: 39 Celsius Power Cycle Min/Max Temperature: 23/43 Celsius Lifetime Min/Max Temperature: 15/44 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 5 minutes Temperature Logging Interval: 5 minutes Min/Max recommended Temperature: -5/80 Celsius Min/Max Temperature Limit: -10/85 Celsius Temperature History Size (Index): 128 (51) Index Estimated Time Temperature Celsius 52 2014-07-19 05:15 39 ******************** 53 2014-07-19 05:20 35 **************** 54 2014-07-19 05:25 37 ****************** 55 2014-07-19 05:30 38 ******************* 56 2014-07-19 05:35 37 ****************** 57 2014-07-19 05:40 30 *********** 58 2014-07-19 05:45 34 *************** 59 2014-07-19 05:50 37 ****************** 60 2014-07-19 05:55 38 ******************* 61 2014-07-19 06:00 36 ***************** 62 2014-07-19 06:05 31 ************ 63 2014-07-19 06:10 35 **************** 64 2014-07-19 06:15 37 ****************** 65 2014-07-19 06:20 38 ******************* 66 2014-07-19 06:25 31 ************ 67 2014-07-19 06:30 35 **************** 68 2014-07-19 06:35 37 ****************** 69 2014-07-19 06:40 38 ******************* 70 2014-07-19 06:45 30 *********** 71 2014-07-19 06:50 33 ************** 72 2014-07-19 06:55 33 ************** 73 2014-07-19 07:00 30 *********** 74 2014-07-19 07:05 33 ************** 75 2014-07-19 07:10 35 **************** 76 2014-07-19 07:15 34 *************** 77 2014-07-19 07:20 30 *********** 78 2014-07-19 07:25 33 ************** 79 2014-07-19 07:30 35 **************** 80 2014-07-19 07:35 36 ***************** 81 2014-07-19 07:40 35 **************** 82 2014-07-19 07:45 30 *********** 83 2014-07-19 07:50 34 *************** 84 2014-07-19 07:55 36 ***************** 85 2014-07-19 08:00 37 ****************** 86 2014-07-19 08:05 32 ************* 87 2014-07-19 08:10 33 ************** 88 2014-07-19 08:15 31 ************ 89 2014-07-19 08:20 35 **************** 90 2014-07-19 08:25 37 ****************** 91 2014-07-19 08:30 38 ******************* 92 2014-07-19 08:35 37 ****************** 93 2014-07-19 08:40 30 *********** 94 2014-07-19 08:45 34 *************** 95 2014-07-19 08:50 37 ****************** 96 2014-07-19 08:55 38 ******************* 97 2014-07-19 09:00 36 ***************** 98 2014-07-19 09:05 32 ************* 99 2014-07-19 09:10 36 ***************** 100 2014-07-19 09:15 38 ******************* 101 2014-07-19 09:20 39 ******************** 102 2014-07-19 09:25 31 ************ 103 2014-07-19 09:30 35 **************** 104 2014-07-19 09:35 38 ******************* 105 2014-07-19 09:40 39 ******************** 106 2014-07-19 09:45 38 ******************* 107 2014-07-19 09:50 32 ************* 108 2014-07-19 09:55 33 ************** 109 2014-07-19 10:00 34 *************** 110 2014-07-19 10:05 32 ************* 111 2014-07-19 10:10 36 ***************** 112 2014-07-19 10:15 38 ******************* 113 2014-07-19 10:20 37 ****************** 114 2014-07-19 10:25 32 ************* 115 2014-07-19 10:30 36 ***************** 116 2014-07-19 10:35 38 ******************* 117 2014-07-19 10:40 39 ******************** 118 2014-07-19 10:45 30 *********** 119 2014-07-19 10:50 34 *************** 120 2014-07-19 10:55 36 ***************** 121 2014-07-19 11:00 37 ****************** 122 2014-07-19 11:05 37 ****************** 123 2014-07-19 11:10 32 ************* 124 2014-07-19 11:15 35 **************** 125 2014-07-19 11:20 37 ****************** 126 2014-07-19 11:25 38 ******************* 127 2014-07-19 11:30 37 ****************** 0 2014-07-19 11:35 33 ************** 1 2014-07-19 11:40 37 ****************** 2 2014-07-19 11:45 39 ******************** 3 2014-07-19 11:50 40 ********************* 4 2014-07-19 11:55 32 ************* 5 2014-07-19 12:00 36 ***************** 6 2014-07-19 12:05 38 ******************* 7 2014-07-19 12:10 39 ******************** 8 2014-07-19 12:15 39 ******************** 9 2014-07-19 12:20 33 ************** 10 2014-07-19 12:25 37 ****************** 11 2014-07-19 12:30 39 ******************** 12 2014-07-19 12:35 40 ********************* 13 2014-07-19 12:40 38 ******************* 14 2014-07-19 12:45 34 *************** 15 2014-07-19 12:50 37 ****************** 16 2014-07-19 12:55 34 *************** 17 2014-07-19 13:00 37 ****************** 18 2014-07-19 13:05 39 ******************** 19 2014-07-19 13:10 39 ******************** 20 2014-07-19 13:15 33 ************** 21 2014-07-19 13:20 37 ****************** 22 2014-07-19 13:25 39 ******************** 23 2014-07-19 13:30 40 ********************* 24 2014-07-19 13:35 40 ********************* 25 2014-07-19 13:40 31 ************ 26 2014-07-19 13:45 35 **************** 27 2014-07-19 13:50 38 ******************* 28 2014-07-19 13:55 39 ******************** 29 2014-07-19 14:00 37 ****************** 30 2014-07-19 14:05 29 ********** 31 2014-07-19 14:10 33 ************** 32 2014-07-19 14:15 35 **************** 33 2014-07-19 14:20 36 ***************** 34 2014-07-19 14:25 35 **************** 35 2014-07-19 14:30 39 ******************** 36 2014-07-19 14:35 41 ********************** 37 2014-07-19 14:40 43 ************************ 38 2014-07-19 14:45 42 *********************** 39 2014-07-19 14:50 35 **************** 40 2014-07-19 14:55 39 ******************** 41 2014-07-19 15:00 41 ********************** 42 2014-07-19 15:05 43 ************************ 43 2014-07-19 15:10 41 ********************** 44 2014-07-19 15:15 35 **************** 45 2014-07-19 15:20 39 ******************** 46 2014-07-19 15:25 41 ********************** 47 2014-07-19 15:30 43 ************************ 48 2014-07-19 15:35 41 ********************** 49 2014-07-19 15:40 35 **************** 50 2014-07-19 15:45 37 ****************** 51 2014-07-19 15:50 37 ****************** SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 4 0 Command failed due to ICRC error 0x0002 4 0 R_ERR response for data FIS 0x0003 4 0 R_ERR response for device-to-host data FIS 0x0004 4 0 R_ERR response for host-to-device data FIS 0x0005 4 0 R_ERR response for non-data FIS 0x0006 4 0 R_ERR response for device-to-host non-data FIS 0x0007 4 0 R_ERR response for host-to-device non-data FIS 0x0008 4 0 Device-to-host non-data FIS retries 0x0009 4 0 Transition from drive PhyRdy to drive PhyNRdy 0x000a 4 0 Device-to-host register FISes sent due to a COMRESET 0x000b 4 0 CRC errors within host-to-device FIS 0x000d 4 0 Non-CRC errors within host-to-device FIS 0x000f 4 0 R_ERR response for host-to-device data FIS, CRC 0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC 0x8e00 4 0 Vendor specific 0x8e01 4 0 Vendor specific 0x8e02 4 0 Vendor specific 0x8e03 4 0 Vendor specific 0x8e04 4 0 Vendor specific 0x8e05 4 0 Vendor specific 0x8e06 4 0 Vendor specific 0x8e07 4 0 Vendor specific 0x8e08 4 0 Vendor specific 0x8e09 4 0 Vendor specific 0x8e0a 4 0 Vendor specific 0x8e0b 4 0 Vendor specific 0x8e0c 4 0 Vendor specific 0x8e0d 4 0 Vendor specific 0x8e0e 4 0 Vendor specific 0x8e0f 4 0 Vendor specific 0x8e10 4 0 Vendor specific 0x8e11 4 0 Vendor specific bran:~#
------------------------------------------------------------------------------ Want fast and easy access to all the code in your enterprise? Index and search up to 200,000 lines of code with a free copy of Black Duck Code Sight - the same software that powers the world's largest code search on Ohloh, the Black Duck Open Hub! Try it now. http://p.sf.net/sfu/bds
_______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database