Hi!
Drive not in the database.
Info on the label:
Part No. HDEPQ01GEA51
Ser. No. 839DKAN3FVC9
Firmwire FL1A
Rev. No. A1
Please note that the serial number is truncated in the smartctl output
(the same for hdparm).
Datasheet:
http://storage.toshiba.com/docs/product-datasheets/MG03ACAxxx.pdf
--
Alexander Cherepanov
smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-4-amd64] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: TOSHIBA MG03ACA300
Serial Number: 839DKAN3F
LU WWN Device Id: 5 000039 4fbd006a1
Firmware Version: FL1A
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
Sector Size: 512 bytes logical/physical
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Tue Jun 17 21:31:25 2014 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 255) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 050 - 0
2 Throughput_Performance P-S--- 100 100 050 - 0
3 Spin_Up_Time POS--K 100 100 001 - 11747
4 Start_Stop_Count -O--CK 100 100 000 - 1
5 Reallocated_Sector_Ct PO--CK 100 100 050 - 0
7 Seek_Error_Rate PO-R-- 100 100 050 - 0
8 Seek_Time_Performance P-S--- 100 100 050 - 0
9 Power_On_Hours -O--CK 100 100 000 - 0
10 Spin_Retry_Count PO--CK 100 100 030 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 1
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
193 Load_Cycle_Count -O--CK 100 100 000 - 1
194 Temperature_Celsius -O---K 100 100 000 - 27 (Min/Max 22/27)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 253 000 - 0
220 Disk_Shift -O---- 100 100 000 - 0
222 Loaded_Hours -O--CK 100 100 000 - 0
223 Load_Retry_Count -O--CK 100 100 000 - 0
224 Load_Friction -O---K 100 100 000 - 0
226 Load-in_Time -OS--K 100 100 000 - 106
240 Head_Flying_Hours P----- 100 100 001 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
GP/S Log at address 0x00 has 1 sectors [Log Directory]
SMART Log at address 0x01 has 1 sectors [Summary SMART error log]
SMART Log at address 0x02 has 51 sectors [Comprehensive SMART error log]
GP Log at address 0x03 has 64 sectors [Ext. Comprehensive SMART error log]
GP/S Log at address 0x04 has 8 sectors [Device Statistics]
SMART Log at address 0x06 has 1 sectors [SMART self-test log]
GP Log at address 0x07 has 1 sectors [Extended self-test log]
GP Log at address 0x08 has 2 sectors [Power Conditions]
SMART Log at address 0x09 has 1 sectors [Selective self-test log]
GP Log at address 0x10 has 1 sectors [NCQ Command Error]
GP Log at address 0x11 has 1 sectors [SATA Phy Event Counters]
GP/S Log at address 0x80 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x81 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x82 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x83 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x84 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x85 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x86 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x87 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x88 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x89 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x8a has 16 sectors [Host vendor specific log]
GP/S Log at address 0x8b has 16 sectors [Host vendor specific log]
GP/S Log at address 0x8c has 16 sectors [Host vendor specific log]
GP/S Log at address 0x8d has 16 sectors [Host vendor specific log]
GP/S Log at address 0x8e has 16 sectors [Host vendor specific log]
GP/S Log at address 0x8f has 16 sectors [Host vendor specific log]
GP/S Log at address 0x90 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x91 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x92 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x93 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x94 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x95 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x96 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x97 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x98 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x99 has 16 sectors [Host vendor specific log]
GP/S Log at address 0x9a has 16 sectors [Host vendor specific log]
GP/S Log at address 0x9b has 16 sectors [Host vendor specific log]
GP/S Log at address 0x9c has 16 sectors [Host vendor specific log]
GP/S Log at address 0x9d has 16 sectors [Host vendor specific log]
GP/S Log at address 0x9e has 16 sectors [Host vendor specific log]
GP/S Log at address 0x9f has 16 sectors [Host vendor specific log]
GP/S Log at address 0xe0 has 1 sectors [SCT Command/Status]
GP/S Log at address 0xe1 has 1 sectors [SCT Data Transfer]
SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 0 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 1 (0x0001)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: 27 Celsius
Power Cycle Min/Max Temperature: 22/27 Celsius
Lifetime Min/Max Temperature: 22/27 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 5/55 Celsius
Min/Max Temperature Limit: 5/55 Celsius
Temperature History Size (Index): 478 (4)
Index Estimated Time Temperature Celsius
5 2014-06-17 13:34 ? -
... ..(472 skipped). .. -
0 2014-06-17 21:27 ? -
1 2014-06-17 21:28 23 ****
2 2014-06-17 21:29 24 *****
3 2014-06-17 21:30 26 *******
4 2014-06-17 21:31 27 ********
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x0008 4 0 Device-to-host non-data FIS retries
0x000a 4 1 Device-to-host register FISes sent due to a COMRESET
0x000b 4 0 CRC errors within host-to-device FIS
0x000d 4 0 Non-CRC errors within host-to-device FIS
------------------------------------------------------------------------------
HPCC Systems Open Source Big Data Platform from LexisNexis Risk Solutions
Find What Matters Most in Your Big Data with HPCC Systems
Open Source. Fast. Scalable. Simple. Ideal for Dirty Data.
Leverages Graph Analysis for Fast Processing & Easy Data Exploration
http://p.sf.net/sfu/hpccsystems
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database