Hi,
Here is a new unknown external USB bridge to SATA drive:
New USB device found, idVendor=059b, idProduct=047a
New USB device strings: Mfr=10, Product=11, SerialNumber=5
Product: Iomega Select HDD
Manufacturer: Iomega
The full lsusb is attached to this mail.
The drive is already in database (SAMSUNG HM321HI PQ: 0 ANSI: 2 CCS, 320GB).
$ sudo smartctl -a /dev/sdb
smartctl 6.2 2013-04-20 r3812 [i686-linux-3.8.0-27-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
/dev/sdb: Unknown USB bridge [0x059b:0x047a (0x100)]
Please specify device type with the -d option.
Although device types usbjmicron,0 and usbjmicron,p seem to work,
I'm using device type "sat" with success.
Thanks for such great tool that Smartmontools is.
Cheers
--
Stephane
Bus 002 Device 014: ID 059b:047a Iomega Corp. Select Portable Hard Drive
Device Descriptor:
bLength 18
bDescriptorType 1
bcdUSB 2.00
bDeviceClass 0 (Defined at Interface level)
bDeviceSubClass 0
bDeviceProtocol 0
bMaxPacketSize0 64
idVendor 0x059b Iomega Corp.
idProduct 0x047a Select Portable Hard Drive
bcdDevice 1.00
iManufacturer 10 Iomega
iProduct 11 Iomega Select HDD
iSerial 5 25D307851FFF
bNumConfigurations 1
Configuration Descriptor:
bLength 9
bDescriptorType 2
wTotalLength 32
bNumInterfaces 1
bConfigurationValue 1
iConfiguration 4 USB Mass Storage
bmAttributes 0xc0
Self Powered
MaxPower 2mA
Interface Descriptor:
bLength 9
bDescriptorType 4
bInterfaceNumber 0
bAlternateSetting 0
bNumEndpoints 2
bInterfaceClass 8 Mass Storage
bInterfaceSubClass 6 SCSI
bInterfaceProtocol 80 Bulk-Only
iInterface 6 MSC Bulk-Only Transfer
Endpoint Descriptor:
bLength 7
bDescriptorType 5
bEndpointAddress 0x81 EP 1 IN
bmAttributes 2
Transfer Type Bulk
Synch Type None
Usage Type Data
wMaxPacketSize 0x0200 1x 512 bytes
bInterval 0
Endpoint Descriptor:
bLength 7
bDescriptorType 5
bEndpointAddress 0x02 EP 2 OUT
bmAttributes 2
Transfer Type Bulk
Synch Type None
Usage Type Data
wMaxPacketSize 0x0200 1x 512 bytes
bInterval 0
Device Qualifier (for other device speed):
bLength 10
bDescriptorType 6
bcdUSB 2.00
bDeviceClass 0 (Defined at Interface level)
bDeviceSubClass 0
bDeviceProtocol 0
bMaxPacketSize0 64
bNumConfigurations 1
Device Status: 0x0001
Self Powered
------------------------------------------------------------------------------
Put Bad Developers to Shame
Dominate Development with Jenkins Continuous Integration
Continuously Automate Build, Test & Deployment
Start a new project now. Try Jenkins in the cloud.
http://p.sf.net/sfu/13600_Cloudbees
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database