Hi,
today I got my Order with two USB3 Chassis from Fantec- both Chipsets
currently not listed in smartmontools/usb.ids.
2.5" USB3 Chassis
Name: FANTEC DB-229U3
URL:
http://www.fantec.de/produkte/speicherprodukte/festplattengehaeuse/25-zoll-festplattengehaeuse/produkt/details/artikel/1464_fantec_db_229u3/
lsusb: Bus 004 Device 002: ID 174c:5136 ASMedia Technology Inc.
dmesg:
[ 2.387427] usb 4-1: Manufacturer: ASMedia
[ 4.533395] scsi 6:0:0:0: Direct-Access ASMT 2105
0 PQ: 0 ANSI: 6
works with option "-d sat"
-------------------
3.5" USB3 Chassis
Name: FANTEC ER-35U3
URL:
http://www.fantec.de/produkte/speicherprodukte/festplattengehaeuse/35-zoll-festplattengehaeuse/produkt/details/artikel/1643_fantec_er_35u3/
lsusb: Bus 004 Device 003: ID 2537:1068
Bus 004 Device 002: ID 174c:5136 ASMedia Technology Inc.
dmesg:
[ 1046.604292] usb 4-2: Product: NS1068
[ 1046.604296] usb 4-2: Manufacturer: Norelsys
works with option "-d sat"
If you need any additional information, let me know.
Kind regards,
Michael!
smartctl 6.3 2014-01-01 r3871 [x86_64-linux-3.12.6-300.fc20.x86_64] (local
build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Red (AF)
Device Model: WDC WD10JFCX-68N6GN0
Serial Number: WD-WXD1E33VHAM6
LU WWN Device Id: 5 0014ee 25e35796c
Firmware Version: 01.01A01
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Sat Jan 4 14:55:37 2014 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (17520) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 196) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x703d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 100 253 051 Pre-fail Always
- 0
3 Spin_Up_Time 0x0027 100 253 021 Pre-fail Always
- 0
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always
- 2
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always
- 0
7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always
- 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always
- 0
10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always
- 0
11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always
- 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always
- 2
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always
- 1
193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always
- 4
194 Temperature_Celsius 0x0022 116 116 000 Old_age Always
- 31
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always
- 0
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x0032 200 253 000 Old_age Always
- 0
200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline
- 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
smartctl 6.3 2014-01-01 r3871 [x86_64-linux-3.12.6-300.fc20.x86_64] (local
build)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda ES.2
Device Model: ST31000340NS
Serial Number: 9QJ6S3HV
LU WWN Device Id: 5 000c50 02a2be46c
Firmware Version: SN06
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 2.6, 1.5 Gb/s
Local Time is: Sat Jan 4 14:55:59 2014 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART STATUS RETURN: incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 642) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 224) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x103d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 066 063 044 Pre-fail Always
- 126333713
3 Spin_Up_Time 0x0003 098 098 000 Pre-fail Always
- 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always
- 39
5 Reallocated_Sector_Ct 0x0033 094 094 036 Pre-fail Always
- 135
7 Seek_Error_Rate 0x000f 075 060 030 Pre-fail Always
- 8658255396
9 Power_On_Hours 0x0032 097 097 000 Old_age Always
- 2895
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always
- 0
12 Power_Cycle_Count 0x0032 100 037 020 Old_age Always
- 38
184 End-to-End_Error 0x0032 100 100 099 Old_age Always
- 0
187 Reported_Uncorrect 0x0032 064 064 000 Old_age Always
- 36
188 Command_Timeout 0x0032 100 099 000 Old_age Always
- 4295032833
189 High_Fly_Writes 0x003a 098 098 000 Old_age Always
- 2
190 Airflow_Temperature_Cel 0x0022 072 051 045 Old_age Always
- 28 (Min/Max 21/28)
194 Temperature_Celsius 0x0022 028 049 000 Old_age Always
- 28 (0 17 0 0 0)
195 Hardware_ECC_Recovered 0x001a 051 040 000 Old_age Always
- 126333713
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always
- 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 0 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
Rapidly troubleshoot problems before they affect your business. Most IT
organizations don't have a clear picture of how application performance
affects their revenue. With AppDynamics, you get 100% visibility into your
Java,.NET, & PHP application. Start your 15-day FREE TRIAL of AppDynamics Pro!
http://pubads.g.doubleclick.net/gampad/clk?id=84349831&iu=/4140/ostg.clktrk
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database