Hello!
Oddly enough, the mailing list took the attachment as text, but ignored my
text, so here it is again, in plain text:
Note - use of "-d sat" parameter to detect this drive is required. And its
odd...
---
Hello!
Please add WD My Passport Ultra 1Gb version to the database.
The drive is not autodetected, "-d sat" key is needed. But afterwards, it works
good.
Due to this, frontends such as Gsmartctl can't work with the drive directly.
Thanks a bunch!
----
Bus 001 Device 003: ID 1058:0820 Western Digital Technologies, Inc.
smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.12.5-3.g48b587a-desktop] (SUSE
RPM)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Western Digital My Passport (USB, AF)
Device Model: WDC WD10JMVW-11AJGS2
Serial Number: WD-WXH1A6304836
LU WWN Device Id: 5 0014ee 2094f03ae
Firmware Version: 01.01A01
User Capacity: 1,000,171,332,096 bytes [1.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Fri Jan 3 06:23:36 2014 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART STATUS RETURN: incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (18900) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 211) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x7035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 100 253 051 Pre-fail Always
- 0
3 Spin_Up_Time 0x0027 100 253 021 Pre-fail Always
- 0
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always
- 9
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always
- 0
7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always
- 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always
- 0
10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always
- 0
11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always
- 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always
- 9
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always
- 7
193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always
- 4
194 Temperature_Celsius 0x0022 119 118 000 Old_age Always
- 28
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always
- 0
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always
- 0
200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline
- 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
Rapidly troubleshoot problems before they affect your business. Most IT
organizations don't have a clear picture of how application performance
affects their revenue. With AppDynamics, you get 100% visibility into your
Java,.NET, & PHP application. Start your 15-day FREE TRIAL of AppDynamics Pro!
http://pubads.g.doubleclick.net/gampad/clk?id=84349831&iu=/4140/ostg.clktrk
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database