Hi,
this is smartctl log of a Plextor PX-128M5Pro drive.
smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.11-2-amd64] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: PLEXTOR PX-128M5Pro
Firmware Version: 1.05
User Capacity: 128,035,676,160 bytes [128 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA8-ACS, ATA/ATAPI-7 T13/1532D revision 4a
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon Dec 16 06:37:32 2013 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 10) seconds.
Offline data collection
capabilities: (0x15) SMART execute Offline immediate.
No Auto Offline data collection support.
Abort Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0002) Does not save SMART data before
entering power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x00) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 10) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO---- 100 100 070 - 0
5 Reallocated_Sector_Ct PO---- 100 100 000 - 0
9 Power_On_Hours -O---- 100 100 000 - 3
12 Power_Cycle_Count -O---- 100 100 000 - 7
177 Wear_Leveling_Count PO---- 100 100 000 - 614
178 Used_Rsvd_Blk_Cnt_Chip PO---- 100 100 000 - 0
181 Program_Fail_Cnt_Total PO---- 100 100 000 - 0
182 Erase_Fail_Count_Total PO---- 100 100 000 - 0
187 Reported_Uncorrect -O---- 100 100 000 - 0
192 Power-Off_Retract_Count PO---- 100 100 000 - 8
196 Reallocated_Event_Count PO---- 100 100 000 - 0
198 Offline_Uncorrectable PO---- 100 100 000 - 0
199 UDMA_CRC_Error_Count PO---- 100 100 000 - 0
232 Available_Reservd_Space PO---- 100 100 010 - 0
241 Total_LBAs_Written PO---- 100 100 000 - 1678
242 Total_LBAs_Read PO---- 100 100 000 - 1877
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 0
SMART Log Directory Version 0
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters
0x80-0x9f GPL,SL R/W 1 Host vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 0
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 1024 -
# 2 Short offline Completed without error 00% 1536 -
Selective Self-tests/Logging not supported
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
SCT Support Level: 1
Device State: Active (0)
Current Temperature: ? Celsius
Power Cycle Min/Max Temperature: ?/ ? Celsius
Lifetime Min/Max Temperature: ?/ ? Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 0 minutes
Temperature Logging Interval: 0 minutes
Min/Max recommended Temperature: ?/ ? Celsius
Min/Max Temperature Limit: ?/ ? Celsius
Temperature History Size (Index): 128 (0)
Index Estimated Time Temperature Celsius
1 2013-12-16 04:30 ? -
... ..(126 skipped). .. -
0 2013-12-16 06:37 ? -
SCT Error Recovery Control:
Read: 2 (0.2 seconds)
Write: 2 (0.2 seconds)
Device Statistics (GP Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 17 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
------------------------------------------------------------------------------
Rapidly troubleshoot problems before they affect your business. Most IT
organizations don't have a clear picture of how application performance
affects their revenue. With AppDynamics, you get 100% visibility into your
Java,.NET, & PHP application. Start your 15-day FREE TRIAL of AppDynamics Pro!
http://pubads.g.doubleclick.net/gampad/clk?id=84349831&iu=/4140/ostg.clktrk
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database