Attached ia info about a Samsung 200GB 3.5" SSD I have here... Ben

--------------------------------------------------------------------
mail2web - Check your email from the web at
http://link.mail2web.com/mail2web

smartctl 5.43 2012-06-30 r3573 [i686-w64-mingw32-xp-sp3] (sf-5.43-1)
Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     SAMSUNG MCCPE2HGGAXP-0VCC3
Serial Number:    S0HTNEAZ501608
LU WWN Device Id: 5 002538 1500021a2
Firmware Version: VCC16C4Q
User Capacity:    200,049,647,616 bytes [200 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4c
Local Time is:    Sun Dec 15 21:25:02 2013 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x02) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                ( 7260) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 121) minutes.
SCT capabilities:              (0x0001) SCT Status supported.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002a   200   200   000    Old_age   Always       
-       0
  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always       
-       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       0
 12 Power_Cycle_Count       0x0032   099   099   000    Old_age   Always       
-       6
 14 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       
-       256
 15 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       
-       186
 16 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       
-       10496
 17 Unknown_Attribute       0x0032   094   094   000    Old_age   Always       
-       9947
173 Unknown_Attribute       0x0032   099   099   000    Old_age   Always       
-       1
178 Used_Rsvd_Blk_Cnt_Chip  0x0032   072   072   000    Old_age   Always       
-       23
180 Unused_Rsvd_Blk_Cnt_Tot 0x0032   100   100   000    Old_age   Always       
-       0
181 Program_Fail_Cnt_Total  0x0032   100   100   000    Old_age   Always       
-       0
182 Erase_Fail_Count_Total  0x0032   100   100   000    Old_age   Always       
-       0
183 Runtime_Bad_Block       0x0033   100   100   040    Pre-fail  Always       
-       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       
-       0
190 Airflow_Temperature_Cel 0x0032   100   100   000    Old_age   Always       
-       0
194 Temperature_Celsius     0x0022   081   080   000    Old_age   Always       
-       24
195 Hardware_ECC_Recovered  0x002a   200   200   000    Old_age   Always       
-       0
197 Current_Pending_Sector  0x0032   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0030   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x0032   100   100   000    Old_age   Always       
-       0
202 Data_Address_Mark_Errs  0x0023   100   075   050    Pre-fail  Always       
-       0
234 Unknown_Attribute       0x0032   099   099   000    Old_age   Always       
-       2442
240 Head_Flying_Hours       0x0032   100   100   000    Old_age   Always       
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%         0         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
Rapidly troubleshoot problems before they affect your business. Most IT 
organizations don't have a clear picture of how application performance 
affects their revenue. With AppDynamics, you get 100% visibility into your 
Java,.NET, & PHP application. Start your 15-day FREE TRIAL of AppDynamics Pro!
http://pubads.g.doubleclick.net/gampad/clk?id=84349831&iu=/4140/ostg.clktrk
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to