OCZ-Vertex-1.10 is not included in the the database.
Update-smart-drive-db does not work.
Ran smartctl -t short /dev/sda
Output of smartctl -x /dev/sda attached
smartctl 6.0 2012-10-10 r3643 [x86_64-linux-3.9.10-100.fc17.x86_64] (local
build)
Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: OCZ-VERTEX v1.10
Serial Number: 35N61JJI5B81X0E4D0F5
Firmware Version: 1370
User Capacity: 128,035,676,160 bytes [128 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Tue Aug 13 21:24:13 2013 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, NOT FROZEN [SEC1]
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x1d) SMART execute Offline immediate.
No Auto Offline data collection support.
Abort Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 0) minutes.
Extended self-test routine
recommended polling time: ( 0) minutes.
SMART Attributes Data Structure revision number: 5
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate ------ 005 000 000 - 0
9 Power_On_Hours ------ 176 039 000 - 0
12 Power_Cycle_Count ------ 171 012 000 - 0
184 End-to-End_Error ------ 033 000 000 - 0
195 Hardware_ECC_Recovered ------ 000 000 000 - 0
196 Reallocated_Event_Count ------ 000 000 000 - 0
197 Current_Pending_Sector ------ 000 000 000 - 0
198 Offline_Uncorrectable ------ 178 069 000 - 227237
199 UDMA_CRC_Error_Count ------ 098 163 000 - 224404
200 Unknown_SSD_Attribute ------ 130 125 000 - 7235
201 Unknown_SSD_Attribute ------ 162 137 000 - 1435
202 Unknown_SSD_Attribute ------ 100 071 000 - 1486
203 Run_Out_Cancel ------ 084 094 000 - 41003
204 Soft_ECC_Correction ------ 000 000 000 - 0
205 Thermal_Asperity_Rate ------ 160 134 000 - 1
206 Unknown_SSD_Attribute ------ 000 000 000 - 0
207 Unknown_SSD_Attribute ------ 236 033 000 - 0
208 Unknown_SSD_Attribute ------ 052 069 000 - 0
209 Unknown_SSD_Attribute ------ 083 000 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
GP/S Log at address 0x00 has 1 sectors [Log Directory]
GP/S Log at address 0x01 has 1 sectors [Summary SMART error log]
GP/S Log at address 0x02 has 51 sectors [Comprehensive SMART error log]
GP/S Log at address 0x03 has 77 sectors [Ext. Comprehensive SMART error log]
GP/S Log at address 0x06 has 1 sectors [SMART self-test log]
GP/S Log at address 0x07 has 1 sectors [Extended self-test log]
GP/S Log at address 0x09 has 1 sectors [Selective self-test log]
GP/S Log at address 0x10 has 1 sectors [NCQ Command Error log]
GP/S Log at address 0x11 has 1 sectors [SATA Phy Event Counters]
GP Log at address 0xa0 has 4096 sectors [Device vendor specific log]
Warning! SMART Extended Comprehensive Error Log Structure (77/77) error:
invalid SMART checksum.
SMART Extended Comprehensive Error Log Version: 49 (77 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 175 -
Selective Self-tests/Logging not supported
SCT Commands not supported
Device Statistics (GP Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11)
[Reserved: 0x00 0x00 0x51 0x10]
ID Size Value Description
0x88b0 14: Invalid entry
------------------------------------------------------------------------------
Get 100% visibility into Java/.NET code with AppDynamics Lite!
It's a free troubleshooting tool designed for production.
Get down to code-level detail for bottlenecks, with <2% overhead.
Download for free and get started troubleshooting in minutes.
http://pubads.g.doubleclick.net/gampad/clk?id=48897031&iu=/4140/ostg.clktrk
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database