smartctl 5.42 2011-10-11 r3440 [x86_64-linux-2.6.39.4-1000hz] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     ST3250823ACE
Serial Number:    5ND13Q5X
Firmware Version: 3.03
User Capacity:    250.059.350.016 bytes [250 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   7
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Fri Oct 14 18:13:38 2011 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (15556) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  84) minutes.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   055   048   006    Pre-fail  Always       
-       18317422
  3 Spin_Up_Time            0x0003   097   096   000    Pre-fail  Always       
-       0
  4 Start_Stop_Count        0x0032   098   098   020    Old_age   Always       
-       2348
  5 Reallocated_Sector_Ct   0x0033   096   096   036    Pre-fail  Always       
-       184
  7 Seek_Error_Rate         0x000f   072   060   030    Pre-fail  Always       
-       20531143
  9 Power_On_Hours          0x0032   096   096   000    Old_age   Always       
-       4250
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   098   098   020    Old_age   Always       
-       2212
194 Temperature_Celsius     0x0022   036   050   000    Old_age   Always       
-       36 (0 13 0 0 0)
195 Hardware_ECC_Recovered  0x001a   055   048   000    Old_age   Always       
-       18317422
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       
-       0
200 Multi_Zone_Error_Rate   0x0000   100   253   000    Old_age   Offline      
-       0
202 Data_Address_Mark_Errs  0x0032   100   253   000    Old_age   Always       
-       0

SMART Error Log Version: 1
ATA Error Count: 21 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 21 occurred at disk power-on lifetime: 3804 hours (158 days + 12 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 55 e2 0a 40  Error: UNC at LBA = 0x000ae255 = 713301

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 04 54 e2 0a 40 00      00:00:55.845  READ DMA
  ca 00 04 60 e2 0a 40 00      00:00:53.821  WRITE DMA
  ca 00 04 60 e2 0a 40 00      00:00:52.869  WRITE DMA
  ca 00 40 0c 12 0b 40 00      00:00:52.838  WRITE DMA
  c8 00 40 0c 12 0b 40 00      00:00:52.768  READ DMA

Error 20 occurred at disk power-on lifetime: 3736 hours (155 days + 16 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 04 5c e2 0a 40  Error: UNC 4 sectors at LBA = 0x000ae25c = 713308

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 04 5c e2 0a 40 00      00:00:11.568  READ DMA
  c8 00 04 cc 06 0b 40 00      00:00:11.887  READ DMA
  c8 00 04 58 e2 0a 40 00      00:00:11.730  READ DMA
  c8 00 04 20 0b 00 40 00      00:00:11.657  READ DMA
  c8 00 04 20 00 00 40 00      00:00:11.654  READ DMA

Error 19 occurred at disk power-on lifetime: 3720 hours (155 days + 0 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 66 08 0b 40  Error: UNC at LBA = 0x000b0866 = 723046

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 40 4c 08 0b 40 00      00:00:13.609  READ DMA
  c8 00 04 6c e2 0a 40 00      00:00:12.607  READ DMA
  ca 00 04 60 e2 0a 40 00      00:00:12.545  WRITE DMA
  c8 00 40 0c 12 0b 40 00      00:00:12.368  READ DMA
  c8 00 04 60 e2 0a 40 00      00:00:12.361  READ DMA

Error 18 occurred at disk power-on lifetime: 3717 hours (154 days + 21 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 cd 06 0b 40  Error: UNC at LBA = 0x000b06cd = 722637

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 04 cc 06 0b 40 00      00:00:12.370  READ DMA
  c8 00 04 58 e2 0a 40 00      00:00:12.363  READ DMA
  c8 00 04 20 0b 00 40 00      00:00:12.361  READ DMA
  c8 00 04 20 00 00 40 00      00:00:12.352  READ DMA
  ca 00 04 0c 00 00 40 00      00:00:12.531  WRITE DMA

Error 17 occurred at disk power-on lifetime: 3672 hours (153 days + 0 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 50 13 0b 40  Error: UNC at LBA = 0x000b1350 = 725840

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 e0 40 13 0b 40 00      00:00:55.873  READ DMA
  c8 00 f4 4c 12 0b 40 00      00:00:55.870  READ DMA
  c8 00 04 58 16 01 40 00      00:00:55.867  READ DMA
  c8 00 04 08 11 09 40 00      00:00:55.830  READ DMA
  c8 00 04 04 11 09 40 00      00:00:55.827  READ DMA

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Extended offline    Completed without error       00%      4249         -
# 2  Short offline       Completed without error       00%      4247         -
# 3  Short offline       Aborted by host               10%      4208         -
# 4  Extended offline    Completed without error       00%      4129         -
# 5  Short offline       Completed without error       00%      4128         -
# 6  Short offline       Interrupted (host reset)      10%      4127         -
# 7  Short offline       Interrupted (host reset)      10%      4119         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
All the data continuously generated in your IT infrastructure contains a
definitive record of customers, application performance, security
threats, fraudulent activity and more. Splunk takes this data and makes
sense of it. Business sense. IT sense. Common sense.
http://p.sf.net/sfu/splunk-d2d-oct
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to