Checked the latest SVN trunk and didn't see this. Built from r3412/trunk.
smartctl dump 10 minutes after the self-test was started.
-- DN
Daniel
smartctl 5.42 (build date Aug 27 2011) [x86_64-linux-3.0.3] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: HITACHI HTS722016K9SA00
Serial Number: 080620DP0D70DVGL4TRC
LU WWN Device Id: 5 000cca 53dc840b0
Firmware Version: DCDZC75A
User Capacity: 160,041,885,696 bytes [160 GB]
Sector Size: 512 bytes logical/physical
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 3f
Local Time is: Sat Aug 27 18:44:51 2011 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 645) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 65) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 062 Pre-fail Always
- 0
2 Throughput_Performance 0x0005 116 116 040 Pre-fail Offline
- 3381
3 Spin_Up_Time 0x0007 145 145 033 Pre-fail Always
- 0
4 Start_Stop_Count 0x0012 096 096 000 Old_age Always
- 6948
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always
- 0
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always
- 0
8 Seek_Time_Performance 0x0005 125 125 040 Pre-fail Offline
- 30
9 Power_On_Hours 0x0012 052 052 000 Old_age Always
- 21055
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always
- 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always
- 346
191 G-Sense_Error_Rate 0x000a 100 100 000 Old_age Always
- 0
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always
- 13
193 Load_Cycle_Count 0x0012 010 010 000 Old_age Always
- 908301
194 Temperature_Celsius 0x0002 137 137 000 Old_age Always
- 40 (Min/Max 16/50)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always
- 0
197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always
- 0
223 Load_Retry_Count 0x000a 100 100 000 Old_age Always
- 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 21055 -
# 2 Short offline Completed without error 00% 13987 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
Special Offer -- Download ArcSight Logger for FREE!
Finally, a world-class log management solution at an even better
price-free! And you'll get a free "Love Thy Logs" t-shirt when you
download Logger. Secure your free ArcSight Logger TODAY!
http://p.sf.net/sfu/arcsisghtdev2dev
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database