5.41 source compiled on CentOS 5.6 AMD64 Thanks!
-Derek -- Derek W. Keoughan, President Finnegan Software, Inc., Brampton, Ontario, Canada http://www.finnsoft.com 416-410-4774 phone 800-258-0033 toll free 905-846-5516 fax Celebrating 16 years of "happily purring" computing Founded 1995-02-02 Specializing in IT Support for small companies without someone on staff Customized PURRformance PC's & Servers, OnSite Services, Installations, Upgrades, Tech Support, Consulting, Networking, Cabling, Internet, Web Hosting, Backups, Hardware, Software, Toner and Ink, Specialty Papers Linux, Windows 7/Vista/XP/2000/NT/Me/9x, eComStation, OS/2 Warp/Server Member - Brampton Board of Trade FinnSoft "CyberCat" logo clothing and more http://www.cafepress.com/finnsoft View my profile on LinkedIn http://www.linkedin.com/in/derekkeoughan
smartctl 5.41 2011-06-09 r3365 [x86_64-linux-2.6.18-238.9.1.el5] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Device Model: ST31000524AS Serial Number: 9VPCKF2D LU WWN Device Id: 5 000c50 035532a00 Firmware Version: JC4B User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 4 Local Time is: Mon Aug 1 13:37:47 2011 EDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 609) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 176) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x103f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 114 100 006 Pre-fail Always - 71048552 3 Spin_Up_Time 0x0003 100 100 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 5 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 100 253 030 Pre-fail Always - 128411 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 31 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 5 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 059 050 045 Old_age Always - 41 (Min/Max 29/45) 194 Temperature_Celsius 0x0022 041 050 000 Old_age Always - 41 (0 29 0 0) 195 Hardware_ECC_Recovered 0x001a 047 027 000 Old_age Always - 71048552 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 52411485913132 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 1945944286 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 23330105 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 2 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
<<attachment: derek.vcf>>
------------------------------------------------------------------------------ BlackBerry® DevCon Americas, Oct. 18-20, San Francisco, CA The must-attend event for mobile developers. Connect with experts. Get tools for creating Super Apps. See the latest technologies. Sessions, hands-on labs, demos & much more. Register early & save! http://p.sf.net/sfu/rim-blackberry-1
_______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database