Hi smartmontools team,

disk model Toshiba MK8050GACY is reported as
"Not in smartctl database" (by smartctl V5.41).

As recommended by the FAQs, I've executed commands
smartctl -t short /dev/hda
smartctl -a /dev/hda

The output of the latter command can be found attached.

Could you please add this device to the database?
Thanks!

Regards
- Stefan Zeier

=================================================================================
Alcatel-Lucent Deutschland AG
Domicile of the Company: Stuttgart - Local Court Stuttgart HRB 4026
Chairman of the Board of Directors: Michael Oppenhoff
Board of Management: Alf Henryk Wulf (Chairman) - Dr. Rainer Fechner - Peter 
Kury
root@foo(root)$ ./smartctl -t short /dev/hda
smartctl 5.41 2011-06-09 r3365 [ppc-linux-2.4.20_mvl31-menem04] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
Sending command: "Execute SMART Short self-test routine immediately in off-line 
mode".
Drive command "Execute SMART Short self-test routine immediately in off-line 
mode" successful.
Testing has begun.
Please wait 2 minutes for test to complete.
Test will complete after Thu Jul 14 14:05:56 2011

root@foo(root)$ ./smartctl -a /dev/hda
smartctl 5.41 2011-06-09 r3365 [ppc-linux-2.4.20_mvl31-menem04] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     TOSHIBA MK8050GACY
Serial Number:    Z0B8T01LT
Firmware Version: TF105A
User Capacity:    80,026,361,856 bytes [80.0 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   7
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Thu Jul 14 14:07:06 2011 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x80) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (  120) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  62) minutes.
SCT capabilities:              (0x0011) SCT Status supported.
                                        SCT Feature Control supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   100   100   050    Pre-fail  Always       
-       0
  2 Throughput_Performance  0x0005   100   100   050    Pre-fail  Offline      
-       0
  3 Spin_Up_Time            0x0027   100   100   001    Pre-fail  Always       
-       967
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       
-       7
  5 Reallocated_Sector_Ct   0x0033   100   100   050    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000b   100   100   050    Pre-fail  Always       
-       0
  8 Seek_Time_Performance   0x0005   100   100   050    Pre-fail  Offline      
-       0
  9 Power_On_Hours          0x0032   095   095   000    Old_age   Always       
-       2199
 10 Spin_Retry_Count        0x0033   100   100   030    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       7
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       2
193 Load_Cycle_Count        0x0032   081   081   000    Old_age   Always       
-       190677
194 Temperature_Celsius     0x0022   100   100   000    Old_age   Always       
-       33 (Min/Max 24/37)
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       
-       0
197 Current_Pending_Sector  0x0032   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0030   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       
-       4294967296
220 Disk_Shift              0x0002   100   100   000    Old_age   Always       
-       26
222 Loaded_Hours            0x0032   096   096   000    Old_age   Always       
-       1763
223 Load_Retry_Count        0x0032   100   100   000    Old_age   Always       
-       0
224 Load_Friction           0x0022   100   100   000    Old_age   Always       
-       0
226 Load-in_Time            0x0026   100   100   000    Old_age   Always       
-       350
240 Head_Flying_Hours       0x0001   100   100   001    Pre-fail  Offline      
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%      2199         -
# 2  Extended offline    Completed without error       00%      2192         -
# 3  Short offline       Completed without error       00%      2165         -
# 4  Extended offline    Completed without error       00%      2144         -
# 5  Short offline       Completed without error       00%      2117         -
# 6  Extended offline    Completed without error       00%      2072         -
# 7  Short offline       Completed without error       00%      2045         -
# 8  Extended offline    Completed without error       00%      2024         -
# 9  Short offline       Completed without error       00%      1997         -
#10  Extended offline    Completed without error       00%      1975         -
#11  Short offline       Completed without error       00%      1949         -
#12  Extended offline    Completed without error       00%      1903         -
#13  Short offline       Completed without error       00%      1876         -
#14  Extended offline    Completed without error       00%      1855         -
#15  Short offline       Completed without error       00%      1828         -
#16  Extended offline    Completed without error       00%      1807         -
#17  Short offline       Completed without error       00%      1780         -
#18  Extended offline    Completed without error       00%      1735         -
#19  Short offline       Completed without error       00%      1708         -
#20  Extended offline    Completed without error       00%      1686         -
#21  Short offline       Completed without error       00%      1660         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

root@foo(root)$ 
------------------------------------------------------------------------------
AppSumo Presents a FREE Video for the SourceForge Community by Eric 
Ries, the creator of the Lean Startup Methodology on "Lean Startup 
Secrets Revealed." This video shows you how to validate your ideas, 
optimize your ideas and identify your business strategy.
http://p.sf.net/sfu/appsumosfdev2dev
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to