Dear all,
What can I do now?
--
Best regards
Guido
----------------------------------------------------
Holimatic GmbH Telematic Consulting
Guido Hollenstein EMAIL: webmas...@holimatic.com
Obere Weidstrasse 8 TEL: +41 (0)41 790 65 57
CH-6343 Rotkreuz FAX: +41 (0)41 790 65 56
Switzerland MOB: +41 (0)79 524 81 72
Webseite WWW: http://www.holimatic.com
----------------------------------------------------
smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: FUJITSU MHZ2320BJ G2
Serial Number: K837T9B266N4
Firmware Version: 891A
User Capacity: 320'072'933'376 bytes
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 3f
Local Time is: Sun May 1 10:52:09 2011 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (1192) seconds.
Offline data collection
capabilities: (0x51) SMART execute Offline immediate.
No Auto Offline data collection support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 163) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 100 100 046 Pre-fail Always
- 145575
2 Throughput_Performance 0x0005 253 253 030 Pre-fail Offline
- 44236800
3 Spin_Up_Time 0x0023 100 100 025 Pre-fail Always
- 2
4 Start_Stop_Count 0x0032 099 099 000 Old_age Always
- 419
5 Reallocated_Sector_Ct 0x0033 253 253 024 Pre-fail Always
- 0
7 Seek_Error_Rate 0x002f 100 100 047 Pre-fail Always
- 2377
8 Seek_Time_Performance 0x0005 253 253 019 Pre-fail Offline
- 0
9 Power_On_Hours 0x0032 085 085 000 Old_age Always
- 7684
10 Spin_Retry_Count 0x0033 253 253 020 Pre-fail Always
- 0
11 Calibration_Retry_Count 0x0032 253 253 000 Old_age Always
- 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always
- 418
182 Unknown_Attribute 0x0032 100 100 000 Old_age Always
- 0
183 Unknown_Attribute 0x0032 253 253 000 Old_age Always
- 0
184 Unknown_Attribute 0x0033 253 253 097 Pre-fail Always
- 0
185 Unknown_Attribute 0x0010 253 253 000 Old_age Offline
- 0
186 Unknown_Attribute 0x0032 253 253 000 Old_age Always
- 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always
- 51539607552
188 Unknown_Attribute 0x0032 100 100 000 Old_age Always
- 0
189 High_Fly_Writes 0x003a 100 100 000 Old_age Always
- 0
190 Airflow_Temperature_Cel 0x0022 056 045 045 Old_age Always
In_the_past 44 (Lifetime Min/Max 24/47)
191 G-Sense_Error_Rate 0x0032 253 253 000 Old_age Always
- 16580608
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always
- 1835036
193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always
- 565
195 Hardware_ECC_Recovered 0x003a 253 253 000 Old_age Always
- 4490
196 Reallocated_Event_Count 0x0032 253 253 000 Old_age Always
- 0
197 Current_Pending_Sector 0x0032 253 253 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0010 253 253 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x003e 253 253 000 Old_age Always
- 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 7684 -
# 2 Extended offline Aborted by host 80% 7684 -
# 3 Short offline Completed without error 00% 2836 -
# 4 Short offline Completed without error 00% 2835 -
# 5 Short offline Completed without error 00% 2835 -
# 6 Short offline Completed without error 00% 2835 -
# 7 Extended offline Aborted by host 80% 3 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
WhatsUp Gold - Download Free Network Management Software
The most intuitive, comprehensive, and cost-effective network
management toolset available today. Delivers lowest initial
acquisition cost and overall TCO of any competing solution.
http://p.sf.net/sfu/whatsupgold-sd
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net