smartctl -a output attached.
smartctl 5.40 2010-10-16 r3189 [FreeBSD 8.2-RELEASE i386] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     QUANTUM FIREBALLlct20 10
Serial Number:    051109244749
Firmware Version: APL.0900
User Capacity:    10 262 568 960 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   5
ATA Standard is:  ATA/ATAPI-5 T13 1321D revision 1
Local Time is:    Thu Mar 17 15:32:33 2011 YEKT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x80) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                 (  51) seconds.
Offline data collection
capabilities:                    (0x1b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        No General Purpose Logging support.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  13) minutes.

SMART Attributes Data Structure revision number: 11
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x0029   100   253   020    Pre-fail  Offline      
-       0
  3 Spin_Up_Time            0x0027   082   080   020    Pre-fail  Always       
-       2333
  4 Start_Stop_Count        0x0032   095   095   008    Old_age   Always       
-       3454
  5 Reallocated_Sector_Ct   0x0033   100   100   020    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000b   100   100   023    Pre-fail  Always       
-       0
  9 Power_On_Hours          0x0012   098   098   001    Old_age   Always       
-       1734
 10 Spin_Retry_Count        0x0026   100   100   000    Old_age   Always       
-       0
 11 Calibration_Retry_Count 0x0013   100   100   020    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   096   096   008    Old_age   Always       
-       3130
 13 Read_Soft_Error_Rate    0x000b   100   100   023    Pre-fail  Always       
-       0
195 Hardware_ECC_Recovered  0x001a   100   100   000    Old_age   Always       
-       516
196 Reallocated_Event_Count 0x0010   100   100   020    Old_age   Offline      
-       0
197 Current_Pending_Sector  0x0032   100   100   020    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0010   100   253   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x001a   200   199   000    Old_age   Always       
-       1

SMART Error Log Version: 0
No Errors Logged

SMART Self-test log structure revision number 0
Warning: ATA Specification requires self-test log structure revision number = 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%      1734         -
# 2  Short offline       Completed without error       00%      1732         -

Device does not support Selective Self Tests/Logging
------------------------------------------------------------------------------
Enable your software for Intel(R) Active Management Technology to meet the
growing manageability and security demands of your customers. Businesses
are taking advantage of Intel(R) vPro (TM) technology - will your software 
be a part of the solution? Download the Intel(R) Manageability Checker 
today! http://p.sf.net/sfu/intel-dev2devmar
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to