Hello all,
please take a look at the smartctl -a dump attached. The values are off.
Alas, although I did run a short self-test on the SSD, smartctl
apparently was unable to read the result. In fact a lot of input/output
errors seem to occur when trying to read information off the drive.
Is there anything that can be done to fix this?
Thanks and kind regards
Sebastian
smartctl 5.40 2010-10-16 r3189 [x86_64-pc-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Model Family: SandForce Driven SSDs
Device Model: OCZ-VERTEX2
Serial Number: OCZ-123A456B78CD9EF0
Firmware Version: 1.25
User Capacity: 60,022,480,896 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 6
Local Time is: Sat Jan 1 11:57:27 2011 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x7f) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Abort Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 48) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 106 102 050 Pre-fail Always
- 0/12703437
5 Retired_Block_Count 0x0033 100 100 003 Pre-fail Always
- 0
9 Power_On_Hours_and_Msec 0x0032 100 100 000 Old_age Always
- 81h+05m+54.750s
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always
- 24
171 Program_Fail_Count 0x0032 000 000 000 Old_age Always
- 0
172 Erase_Fail_Count 0x0032 000 000 000 Old_age Always
- 0
174 Unexpect_Power_Loss_Ct 0x0030 000 000 000 Old_age Offline
- 4
177 Wear_Range_Delta 0x0000 000 000 000 Old_age Offline
- 0
181 Program_Fail_Count 0x0032 000 000 000 Old_age Always
- 0
182 Erase_Fail_Count 0x0032 000 000 000 Old_age Always
- 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always
- 0
194 Temperature_Celsius 0x0022 001 129 000 Old_age Always
- 1 (0 127 0 129)
195 ECC_Uncorr_Error_Count 0x001c 106 102 000 Old_age Offline
- 0/12703437
196 Reallocated_Event_Count 0x0033 100 100 000 Pre-fail Always
- 0
231 SSD_Life_Left 0x0013 100 100 010 Pre-fail Always
- 0
233 SandForce_Internal 0x0000 000 000 000 Old_age Offline
- 0
234 SandForce_Internal 0x0032 000 000 000 Old_age Always
- 0
241 Lifetime_Writes_GiB 0x0032 000 000 000 Old_age Always
- 0
242 Lifetime_Reads_GiB 0x0032 000 000 000 Old_age Always
- 64
Error SMART Error Log Read failed: Input/output error
Smartctl: SMART Error Log Read Failed
Error SMART Error Self-Test Log Read failed: Input/output error
Smartctl: SMART Self Test Log Read Failed
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
Learn how Oracle Real Application Clusters (RAC) One Node allows customers
to consolidate database storage, standardize their database environment, and,
should the need arise, upgrade to a full multi-node Oracle RAC database
without downtime or disruption
http://p.sf.net/sfu/oracle-sfdevnl
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database