Hi,

as far as I can see the latest drivedb.h version already contains the
Western Digital "Scorpio Blue" EIDE family:

[...]
  { "Western Digital Scorpio Blue EIDE family",
    "WDC WD(4|6|8|10|12|16|25)00BEVE-.*",
    "", "", ""
  },
[...]

but the 320GB version is missing.

The output of

# smartctl -a /dev/sda

after a short offline self-test is attached.

Thanks,


Maurizio
smartctl 5.40 2010-07-12 r3124 [i686-pc-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     WDC WD3200BEVE-00A0HT0
Serial Number:    WD-WXE209TLA490
Firmware Version: 11.01A11
User Capacity:    320,072,933,376 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Tue Dec 28 12:51:00 2010 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x85) Offline data collection activity
                                        was aborted by an interrupting command 
from host.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                 (10380) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 122) minutes.
Conveyance self-test routine
recommended polling time:        (   5) minutes.
SCT capabilities:              (0x2037) SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   200   200   051    Pre-fail  Always       
-       42
  3 Spin_Up_Time            0x0027   187   186   021    Pre-fail  Always       
-       1616
  4 Start_Stop_Count        0x0032   099   099   000    Old_age   Always       
-       1207
  5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x002e   100   253   000    Old_age   Always       
-       0
  9 Power_On_Hours          0x0032   096   096   000    Old_age   Always       
-       3517
 10 Spin_Retry_Count        0x0033   100   100   051    Pre-fail  Always       
-       0
 11 Calibration_Retry_Count 0x0032   100   100   000    Old_age   Always       
-       0
 12 Power_Cycle_Count       0x0032   099   099   000    Old_age   Always       
-       1195
192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age   Always       
-       51
193 Load_Cycle_Count        0x0032   185   185   000    Old_age   Always       
-       45983
194 Temperature_Celsius     0x0022   107   095   000    Old_age   Always       
-       40
196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always       
-       0
197 Current_Pending_Sector  0x0032   200   200   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0030   100   253   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       
-       0
200 Multi_Zone_Error_Rate   0x0009   200   200   051    Pre-fail  Offline      
-       0

SMART Error Log Version: 1
ATA Error Count: 35 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 35 occurred at disk power-on lifetime: 810 hours (33 days + 18 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  01 51 05 bc 6d e1 e0  Error: AMNF at LBA = 0x00e16dbc = 14773692

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  24 00 05 bc 6d e1 02 08      00:07:38.196  READ SECTOR(S) EXT
  24 00 05 bc 6d e1 02 08      00:07:35.219  READ SECTOR(S) EXT
  24 00 05 bc 6d e1 02 08      00:07:32.125  READ SECTOR(S) EXT
  10 00 3f 00 00 00 00 08      00:07:32.115  RECALIBRATE [OBS-4]
  24 00 05 bc 6d e1 02 08      00:07:29.184  READ SECTOR(S) EXT

Error 34 occurred at disk power-on lifetime: 810 hours (33 days + 18 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  01 51 05 bc 6d e1 e0  Error: AMNF at LBA = 0x00e16dbc = 14773692

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  24 00 05 bc 6d e1 02 08      00:07:35.219  READ SECTOR(S) EXT
  24 00 05 bc 6d e1 02 08      00:07:32.125  READ SECTOR(S) EXT
  10 00 3f 00 00 00 00 08      00:07:32.115  RECALIBRATE [OBS-4]
  24 00 05 bc 6d e1 02 08      00:07:29.184  READ SECTOR(S) EXT
  24 00 05 bc 6d e1 02 08      00:07:25.934  READ SECTOR(S) EXT

Error 33 occurred at disk power-on lifetime: 810 hours (33 days + 18 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  01 51 05 bc 6d e1 e0  Error: AMNF at LBA = 0x00e16dbc = 14773692

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  24 00 05 bc 6d e1 02 08      00:07:32.125  READ SECTOR(S) EXT
  10 00 3f 00 00 00 00 08      00:07:32.115  RECALIBRATE [OBS-4]
  24 00 05 bc 6d e1 02 08      00:07:29.184  READ SECTOR(S) EXT
  24 00 05 bc 6d e1 02 08      00:07:25.934  READ SECTOR(S) EXT
  24 00 05 bc 6d e1 02 08      00:07:22.801  READ SECTOR(S) EXT

Error 32 occurred at disk power-on lifetime: 810 hours (33 days + 18 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  01 51 05 bc 6d e1 e0  Error: AMNF at LBA = 0x00e16dbc = 14773692

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  24 00 05 bc 6d e1 02 08      00:07:29.184  READ SECTOR(S) EXT
  24 00 05 bc 6d e1 02 08      00:07:25.934  READ SECTOR(S) EXT
  24 00 05 bc 6d e1 02 08      00:07:22.801  READ SECTOR(S) EXT
  24 00 05 bc 6d e1 02 08      00:07:19.862  READ SECTOR(S) EXT
  10 00 3f 00 00 00 00 08      00:07:19.841  RECALIBRATE [OBS-4]

Error 31 occurred at disk power-on lifetime: 810 hours (33 days + 18 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  01 51 05 bc 6d e1 e0  Error: AMNF at LBA = 0x00e16dbc = 14773692

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  24 00 05 bc 6d e1 02 08      00:07:25.934  READ SECTOR(S) EXT
  24 00 05 bc 6d e1 02 08      00:07:22.801  READ SECTOR(S) EXT
  24 00 05 bc 6d e1 02 08      00:07:19.862  READ SECTOR(S) EXT
  10 00 3f 00 00 00 00 08      00:07:19.841  RECALIBRATE [OBS-4]
  24 00 05 bc 6d e1 02 08      00:07:16.914  READ SECTOR(S) EXT

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%      3517         -
# 2  Short offline       Completed without error       00%      3517         -
# 3  Short offline       Completed without error       00%      3508         -
# 4  Extended offline    Completed without error       00%      3508         -
# 5  Short offline       Completed without error       00%      3503         -
# 6  Short offline       Completed without error       00%      3497         -
# 7  Short offline       Completed without error       00%      3487         -
# 8  Short offline       Completed without error       00%      3478         -
# 9  Short offline       Completed without error       00%      3470         -
#10  Extended offline    Completed without error       00%      3469         -
#11  Short offline       Completed without error       00%      3462         -
#12  Short offline       Completed without error       00%      3455         -
#13  Short offline       Completed without error       00%      3446         -
#14  Short offline       Completed without error       00%      3440         -
#15  Short offline       Completed without error       00%      3431         -
#16  Extended offline    Interrupted (host reset)      90%      3428         -
#17  Short offline       Completed without error       00%      3423         -
#18  Short offline       Completed without error       00%      3414         -
#19  Short offline       Completed without error       00%      3410         -
#20  Short offline       Completed without error       00%      3403         -
#21  Short offline       Completed without error       00%      3393         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
Learn how Oracle Real Application Clusters (RAC) One Node allows customers
to consolidate database storage, standardize their database environment, and, 
should the need arise, upgrade to a full multi-node Oracle RAC database 
without downtime or disruption
http://p.sf.net/sfu/oracle-sfdevnl
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to