Hi,

Output below:

smartctl 5.41 2010-11-24 r3216 [x86_64-unknown-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     Hitachi HDS723030ALA640
Serial Number:    XXXXXXXXXXXXXX
Firmware Version: MKAOA3B0
User Capacity:    3,000,592,982,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Sun Dec 19 10:47:13 2010 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x80) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline 
data collection:                 (30695) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 255) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
   1 Raw_Read_Error_Rate     0x000b   100   100   016    Pre-fail  Always       
-       0
   2 Throughput_Performance  0x0005   100   100   054    Pre-fail  Offline      
-       0
   3 Spin_Up_Time            0x0007   100   100   024    Pre-fail  Always       
-       0
   4 Start_Stop_Count        0x0012   100   100   000    Old_age   Always       
-       4
   5 Reallocated_Sector_Ct   0x0033   100   100   005    Pre-fail  Always       
-       0
   7 Seek_Error_Rate         0x000b   100   100   067    Pre-fail  Always       
-       0
   8 Seek_Time_Performance   0x0005   100   100   020    Pre-fail  Offline      
-       0
   9 Power_On_Hours          0x0012   100   100   000    Old_age   Always       
-       4
  10 Spin_Retry_Count        0x0013   100   100   060    Pre-fail  Always       
-       0
  12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       4
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       4
193 Load_Cycle_Count        0x0012   100   100   000    Old_age   Always       
-       4
194 Temperature_Celsius     0x0002   166   166   000    Old_age   Always       
-       36 (Min/Max 24/37)
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       
-       0
197 Current_Pending_Sector  0x0022   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0008   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x000a   200   200   000    Old_age   Always       
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
     1        0        0  Not_testing
     2        0        0  Not_testing
     3        0        0  Not_testing
     4        0        0  Not_testing
     5        0        0  Not_testing
Selective self-test flags (0x0):
   After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.


------------------------------------------------------------------------------
Lotusphere 2011
Register now for Lotusphere 2011 and learn how
to connect the dots, take your collaborative environment
to the next level, and enter the era of Social Business.
http://p.sf.net/sfu/lotusphere-d2d
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to