smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     ST9500530NS
Serial Number:    9SP11LT1
Firmware Version: SN03
User Capacity:    500,107,862,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Tue Oct 19 16:24:42 2010 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82)    Offline data collection activity
                    was completed without error.
                    Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)    The previous self-test routine
completed
                    without error or no self-test has ever
                    been run.
Total time to complete Offline
data collection:          ( 650) seconds.
Offline data collection
capabilities:              (0x7b) SMART execute Offline immediate.
                    Auto Offline data collection on/off support.
                    Suspend Offline collection upon new
                    command.
                    Offline surface scan supported.
                    Self-test supported.
                    Conveyance Self-test supported.
                    Selective Self-test supported.
SMART capabilities:            (0x0003)    Saves SMART data before entering
                    power-saving mode.
                    Supports SMART auto save timer.
Error logging capability:        (0x01)    Error logging supported.
                    General Purpose Logging supported.
Short self-test routine
recommended polling time:      (   1) minutes.
Extended self-test routine
recommended polling time:      ( 120) minutes.
Conveyance self-test routine
recommended polling time:      (   2) minutes.
SCT capabilities:            (0x103d)    SCT Status supported.
                    SCT Feature Control supported.
                    SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   080   063   044    Pre-fail
Always       -       105818960
  3 Spin_Up_Time            0x0003   099   099   000    Pre-fail
Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age
Always       -       15
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail
Always       -       0
  7 Seek_Error_Rate         0x000f   075   060   030    Pre-fail
Always       -       39835950
  9 Power_On_Hours          0x0032   096   096   000    Old_age
Always       -       3737
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail
Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age
Always       -       15
184 Unknown_Attribute       0x0032   100   100   099    Old_age
Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age
Always       -       0
188 Unknown_Attribute       0x0032   100   100   000    Old_age
Always       -       0
189 High_Fly_Writes         0x003a   093   093   000    Old_age
Always       -       7
190 Airflow_Temperature_Cel 0x0022   063   057   045    Old_age
Always       -       37 (Lifetime Min/Max 36/38)
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age
Always       -       0
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age
Always       -       14
193 Load_Cycle_Count        0x0032   100   100   000    Old_age
Always       -       15
194 Temperature_Celsius     0x0022   037   043   000    Old_age
Always       -       37 (0 24 0 0)
195 Hardware_ECC_Recovered  0x001a   043   030   000    Old_age
Always       -       105818960
197 Current_Pending_Sector  0x0012   100   100   000    Old_age
Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age
Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age
Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)
LBA_of_first_error
# 1  Short offline       Completed without error       00%      3737
-

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     ST9500530NS
Serial Number:    9SP11LT1
Firmware Version: SN03
User Capacity:    500,107,862,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Tue Oct 19 16:24:42 2010 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                 ( 650) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 120) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x103d) SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   080   063   044    Pre-fail  Always       
-       105818960
  3 Spin_Up_Time            0x0003   099   099   000    Pre-fail  Always       
-       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       
-       15
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000f   075   060   030    Pre-fail  Always       
-       39835950
  9 Power_On_Hours          0x0032   096   096   000    Old_age   Always       
-       3737
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       
-       15
184 Unknown_Attribute       0x0032   100   100   099    Old_age   Always       
-       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       
-       0
188 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       
-       0
189 High_Fly_Writes         0x003a   093   093   000    Old_age   Always       
-       7
190 Airflow_Temperature_Cel 0x0022   063   057   045    Old_age   Always       
-       37 (Lifetime Min/Max 36/38)
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       
-       0
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       14
193 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       
-       15
194 Temperature_Celsius     0x0022   037   043   000    Old_age   Always       
-       37 (0 24 0 0)
195 Hardware_ECC_Recovered  0x001a   043   030   000    Old_age   Always       
-       105818960
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%      3737         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
Centralized Desktop Delivery: Dell and VMware Reference Architecture
Simplifying enterprise desktop deployment and management using
Dell EqualLogic storage and VMware View: A highly scalable, end-to-end
client virtualization framework. Read more!
http://p.sf.net/sfu/dell-eql-dev2dev
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to