Hello,
Please find attached the output of smartctl -a for a Crucial C300 128MB SSD
after a completed short test. Power_On_Hours and Power_Cycle_Count looks ok
and there are 5 Unknown_Attribute (170 to 174).
--
Benoît.
smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (openSUSE RPM)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: C300-CTFDDAC128MAG
Serial Number: 00000000102002FB6491
Firmware Version: 0002
User Capacity: 128 035 676 160 bytes
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 6
Local Time is: Thu Sep 23 22:15:28 2010 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 595) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 9) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 100 100 000 Pre-fail Always
- 0
5 Reallocated_Sector_Ct 0x0033 100 100 000 Pre-fail Always
- 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always
- 115
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always
- 17
170 Unknown_Attribute 0x0033 100 100 000 Pre-fail Always
- 8819
171 Unknown_Attribute 0x0032 100 100 000 Old_age Always
- 0
172 Unknown_Attribute 0x0032 100 100 000 Old_age Always
- 0
173 Unknown_Attribute 0x0033 100 100 000 Pre-fail Always
- 0
174 Unknown_Attribute 0x0032 100 100 000 Old_age Always
- 0
181 Program_Fail_Cnt_Total 0x0022 100 100 000 Old_age Always
- 0
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always
- 0
184 End-to-End_Error 0x0033 100 100 000 Pre-fail Always
- 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always
- 0
188 Command_Timeout 0x0032 100 100 000 Old_age Always
- 0
189 High_Fly_Writes 0x000e 100 100 000 Old_age Always
- 272
195 Hardware_ECC_Recovered 0x003a 100 100 000 Old_age Always
- 0
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always
- 0
197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x0032 100 100 000 Old_age Always
- 0
202 Data_Address_Mark_Errs 0x0018 100 100 000 Old_age Offline
- 0
206 Flying_Height 0x000e 100 100 000 Old_age Always
- 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 115 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
Start uncovering the many advantages of virtual appliances
and start using them to simplify application deployment and
accelerate your shift to cloud computing.
http://p.sf.net/sfu/novell-sfdev2dev
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database