Hello,
attached is smartctl -a output (following smartctl -t short) for an
Intel X25-V 40GB SSD drive.
smartctl 5.40 2010-09-14 r3150 [x86_64-unknown-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: INTEL SSDSA2M040G2GC
Serial Number: CVGB0031034E040GGN
Firmware Version: 2CV102HD
User Capacity: 40,020,664,320 bytes
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 7
ATA Standard is: ATA/ATAPI-7 T13 1532D revision 1
Local Time is: Thu Sep 16 00:12:16 2010 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 1) seconds.
Offline data collection
capabilities: (0x75) SMART execute Offline immediate.
No Auto Offline data collection support.
Abort Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 1) minutes.
Conveyance self-test routine
recommended polling time: ( 1) minutes.
SMART Attributes Data Structure revision number: 5
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
3 Spin_Up_Time 0x0020 100 100 000 Old_age Offline
- 0
4 Start_Stop_Count 0x0030 100 100 000 Old_age Offline
- 0
5 Reallocated_Sector_Ct 0x0032 100 100 000 Old_age Always
- 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always
- 565
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always
- 486
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always
- 14
225 Load_Cycle_Count 0x0030 200 200 000 Old_age Offline
- 10563
226 Load-in_Time 0x0032 100 100 000 Old_age Always
- 816
227 Torq-amp_Count 0x0032 100 100 000 Old_age Always
- 0
228 Power-off_Retract_Count 0x0032 100 100 000 Old_age Always
- 4278289312
232 Available_Reservd_Space 0x0033 100 100 010 Pre-fail Always
- 0
233 Media_Wearout_Indicator 0x0032 099 099 000 Old_age Always
- 0
184 End-to-End_Error 0x0033 100 100 099 Pre-fail Always
- 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Vendor offline Completed without error 00% 565 -
# 2 Vendor offline Completed without error 00% 565 -
# 3 Offline Completed without error 00% 565 -
Note: selective self-test log revision number (0) not 1 implies that no
selective self-test has ever been run
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been
run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
Start uncovering the many advantages of virtual appliances
and start using them to simplify application deployment and
accelerate your shift to cloud computing.
http://p.sf.net/sfu/novell-sfdev2dev
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database