SAMSUNG HD502HI not in database
Thanks
Marko
# smartctl -t short /dev/sdd
smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
Sending command: "Execute SMART Short self-test routine immediately in off-line
mode".
Drive command "Execute SMART Short self-test routine immediately in off-line
mode" successful.
Testing has begun.
Please wait 2 minutes for test to complete.
Test will complete after Wed Jun 23 14:27:04 2010
Use smartctl -X to abort test.
# smartctl -a /dev/sdd
smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: SAMSUNG HD502HI
Serial Number: S1VZJ9DS702032
Firmware Version: 1AG01118
User Capacity: 500,106,780,160 bytes
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 3b
Local Time is: Wed Jun 23 14:28:13 2010 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (6522) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 110) minutes.
Conveyance self-test routine
recommended polling time: ( 12) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always
- 0
3 Spin_Up_Time 0x0007 091 091 011 Pre-fail Always
- 3590
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always
- 63
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always
- 0
7 Seek_Error_Rate 0x000f 253 253 051 Pre-fail Always
- 0
8 Seek_Time_Performance 0x0025 100 100 015 Pre-fail Offline
- 10069
9 Power_On_Hours 0x0032 099 099 000 Old_age Always
- 4893
10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always
- 0
11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always
- 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always
- 63
13 Read_Soft_Error_Rate 0x000e 100 100 000 Old_age Always
- 0
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always
- 0
184 End-to-End_Error 0x0033 100 100 000 Pre-fail Always
- 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always
- 0
188 Command_Timeout 0x0032 100 100 000 Old_age Always
- 0
190 Airflow_Temperature_Cel 0x0022 070 058 000 Old_age Always
- 30 (Lifetime Min/Max 29/32)
194 Temperature_Celsius 0x0022 068 055 000 Old_age Always
- 32 (Lifetime Min/Max 29/34)
195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always
- 1767389
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always
- 0
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always
- 0
198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always
- 1
200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always
- 0
201 Soft_Read_Error_Rate 0x000a 253 253 000 Old_age Always
- 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours)
LBA_of_first_error
# 1 Short offline Completed without error 00% 4893 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
ThinkGeek and WIRED's GeekDad team up for the Ultimate
GeekDad Father's Day Giveaway. ONE MASSIVE PRIZE to the
lucky parental unit. See the prize list and enter to win:
http://p.sf.net/sfu/thinkgeek-promo
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database