Hi many thanks for the tools, it works flawlessly here.
I just patched to send the output that does not belong to the topology.conf to stderr so I could simply redirect to topology.conf in an automated Slurm install procedure 16c16 < echo Verify the Infiniband interface: >&2 --- > echo Verify the Infiniband interface: 18c18 < if $IBSTAT -l >&2 --- > if $IBSTAT -l 20c20 < echo Infiniband interface OK >&2 --- > echo Infiniband interface OK 22c22 < echo Infiniband interface NOT OK >&2 --- > echo Infiniband interface NOT OK 26c26 < cat <<EOF >&2 --- > cat <<EOF Sincerely damien > On 07 May 2017, at 14:29, Ole Holm Nielsen <[email protected]> wrote: > > > I'm announcing an initial version 0.1 of an Infiniband topology tool > "slurmibtopology.sh" for Slurm. > > I had to create a Slurm topology.conf file and needed an automated way to get > the correct node and switch Infiniband connectivity. The manual page > https://slurm.schedmd.com/topology.conf.html refers to an outdated tool > ib2slurm. > > Inspired by the script in > https://unix.stackexchange.com/questions/255472/text-processing-building-a-slurm-topology-conf-file-from-ibnetdiscover-output > I decided to write a simpler and more understandable tool. It parses the > output of the OFED command "ibnetdiscover" and generates an initial > topology.conf file (which you may want to edit for readability). > > Download the script https://ftp.fysik.dtu.dk/Slurm/slurmibtopology.sh > > Example: Running this script on our Infiniband network: > > # slurmibtopology.sh > Verify the Infiniband interface: > mlx4_0 > Infiniband interface OK > > Generate the Slurm topology.conf file for Infiniband switches: > > # IB switch no. 1: MF0;mell02:IS5030/U1 > SwitchName=ibsw1 Nodes=i[001-028] > # IB switch no. 2: MF0;mell03:IS5030/U1 > SwitchName=ibsw2 Nodes=finbul,i[029-051],niflfs[1-2],niflopt1 > # IB switch no. 3: MF0;mell01:SX6036/U1 > SwitchName=ibsw3 Nodes=g[081-100,102-112],h[001-002] > # IB switch no. 4: MF0;mell04:SX6036/U1 > # NOTICE: This switch has no attached nodes (empty hostlist) > SwitchName=ibsw4 Nodes="" > # IB switch no. 5: Mellanox 4036 # volt01 > SwitchName=ibsw5 Nodes=g[005-008,013-014,016,021-024,029-032,037-040] > # IB switch no. 6: Mellanox 4036 # volt03 > SwitchName=ibsw6 Nodes=g[045-048,053-056,061-064,069-072,077-080] > # IB switch no. 7: Mellanox 4036 # volt04 > SwitchName=ibsw7 Nodes=g[041-044,049-052,057-060,065-068,073-076] > # IB switch no. 8: Mellanox 4036 # volt02 > SwitchName=ibsw8 Nodes=g[001-004,009-012,017-020,025-028,033-036] > # Merging all switches in a top-level spine switch > SwitchName=spineswitch Switches=ibsw[1-8] > > It would be great if other sites could test this tool on their Infiniband > network and report bugs or suggest improvements. > > -- > Ole Holm Nielsen > Department of Physics, Technical University of Denmark
smime.p7s
Description: S/MIME cryptographic signature