The other thing, as several people have noted, is that if if the process
worked previously and none of your conditions have changed (same type and
amount of water, same amount of brewing time, etc) then check for
contamination of the wires or the jar from touching with your fingers, etc.
In other words, don't touch any of these things with your bare fingers, and
clean them with hydrogen peroxide and rinse with distilled water.  Use plain
white paper towels to clean or touch the electrodes or jar.

Dan

On Fri, Oct 15, 2010 at 9:52 AM, Dan Nave <[email protected]> wrote:

> The Utopia Silver generator appears to be a (non current regulated) voltage
> supply with a timer.  Since CS or EIS making is notoriously variable, and as
> the process with no current regulation increases its production of silver
> output into the solution exponentially as the process continues, you can
> easily overshoot the time when you should have stopped brewing and end up
> with too strong of a silver solution.  With that process, you don't know
> what you have as an end product in terms of ppm of silver.
>
> If you standardize your brewing process, always using the same brand of
> distilled water at the same temperature, the same volume of water, and the
> same time on the timer, you should be able to get a fairly consistent
> product.  If you change any of these variables you have to re-figure out
> everything.
>
> Try reducing the time until your final product just gets a slight yellow
> tint, like diluted urine, when it is stabilized.  You can either use this
> timing, or back off slightly until you get a more colorless product.
>
> Dan
>
> On Fri, Oct 15, 2010 at 12:27 AM, <[email protected]> wrote:
>
>>   Hi, I also have Utopia silver and have same problem as
>> Melly. colored/cloudy.   I noticed one rod was overly eroded gathering lots
>> fusses but other rod with smooth surface has no particles around.  Is it
>> safe to drink the solution?
>>
>> I wonder how do you clean the glass/rod before blewing?  I use tap water
>> to clean then rinse with silver water. is it ok?
>>
>> --- On *Thu, 10/14/10, jaxi <[email protected]>* wrote:
>>
>>
>> From: jaxi <[email protected]>
>> Subject: Re: CS>Re: Help please
>> To: [email protected]
>> Date: Thursday, October 14, 2010, 6:11 PM
>>
>> Might help if you specify what brand maker you have or if you made it
>> yourself and if so batteries or AC current.
>>
>> Of course I have been known to be wrong.
>>
>> On Thu, Oct 14, 2010 at 5:54 PM, Melly Bag 
>> <[email protected]<http://us.mc823.mail.yahoo.com/mc/[email protected]>
>> > wrote:
>>
>>   Hi Experts,
>>
>> I brewed EIS today, the silver rods one inch apart.  But i think it is
>> short  from the bottom of the Ball quart jar.  It is color brown and
>> cloudy again with plenty of silver floating on top and fuss at the bottom.
>> Worse still, first time it happened to me, while rinsing and cleaning the
>> rods, i noticed that one had a "waist" like it was overly eroded at that
>> part and ready to break off.  The jar got very warm and so with the rods.
>>
>> What did i do wrong?
>>
>> Thanks.
>>
>> Melly
>>
>>
>>
>> --- On *Thu, 10/14/10, 
>> [email protected]<http://us.mc823.mail.yahoo.com/mc/[email protected]>
>> <[email protected]<http://us.mc823.mail.yahoo.com/mc/[email protected]>
>> >* wrote:
>>
>>
>> From: 
>> [email protected]<http://us.mc823.mail.yahoo.com/mc/[email protected]><
>> [email protected]<http://us.mc823.mail.yahoo.com/mc/[email protected]>
>> >
>> Subject: silver-digest Digest V2010 #834
>> To: 
>> [email protected]<http://us.mc823.mail.yahoo.com/mc/[email protected]>
>> Date: Thursday, October 14, 2010, 2:30 PM
>>
>>
>>
>