> What lead you to the assumption it's ONLY those
> switches? Just because the patch is ONLY for those
> switches doesn't mean that the bug is only for them.
> The reason you only see the patch for 3xxx and newer
> is because the 2xxx was EOL before the patch was
> released...
>
> FabOS is FabOS
What lead you to the assumption it's ONLY those switches? Just because the
patch is ONLY for those switches doesn't mean that the bug is only for them.
The reason you only see the patch for 3xxx and newer is because the 2xxx was
EOL before the patch was released...
FabOS is FabOS, the nature
Gino,
although these messages show some similarity to ones in the Sun Alert
you are referring to, it looks like this is unrelated. Sun Alert 57773
describes symptoms of a problem seen in SAN configurations with specific
switches (Brocade SilkWorm Switch 12000, 24000, 3250, 3850, 3900) with
spe
Hello,
today we made some tests with failed drives on a zpool.
(SNV60, 2xHBA, 4xJBOD connected through 2 Brocade 2800)
On the log we found hundred of the following errors:
Sep 16 12:04:23 svrt12 fp: [ID 517869 kern.info] NOTICE: fp(0): PLOGI to 11dca
failed state=Timeout, reason=Hardware Error
Se