[Discussion]: Making "LIBXL_HOTPLUG_TIMEOUT" configurable through 'xl.conf'

2023-11-15 Thread Divin Raj
Hi Xen community, On one of our internal projects we came across an issue in the toolstack: when multiple network interfaces are initialized concurrently with other system workloads, the execution time of the hotplug script often exceeds 40 seconds, leading to an error. To mitigate this issue,

Re: [Discussion]: Making "LIBXL_HOTPLUG_TIMEOUT" configurable through 'xl.conf'

2023-11-23 Thread Divin Raj
On 11/16/23 9:53 AM, Olaf Hering wrote: Thu, 16 Nov 2023 09:21:06 + Luca Fancellu : I see your patch is handling this issue but maybe was not meant to be upstreamed, so I would like to ask if you are willing to make it upstream-able or if it’s not planned to do so. Right now I do not ha