Yes, now I know that :-D
Thank you, I've learned something new today.
-Original Message-
From: Yan Sklyarenko [mailto:yansklyarenko+...@gmail.com]
Sent: Friday, February 25, 2011 9:34 AM
To: General discussion for Windows Installer XML toolset.
Subject: Re: [WiX-users] How to issue a
If CAQuietExec custom action is used (as mentioned by Ed previously and as
the name of CA suggests), the console window won't be shown.
-- Yan
On Fri, Feb 25, 2011 at 9:13 AM, Dan Vasilov wrote:
>A custom action will do exactly what you need, but please be aware
> your setup users will
A custom action will do exactly what you need, but please be aware
your setup users will
shortly see a command window on the screen.
Are you configuring a WCF-based application? If so, you may want to
ask one of your .NET developers to implement a C#-based custom action to
configur
It seems that I dont break component rules... I just add new component into
existing feature and trying to upgrade.
Besides I put it after InstallInitialize, but now take another problem. If
some of dlls will have lower version - it deleted during upgrade.
If product version 2.0 have bbb.dll versio
In WiX v3.5, MajorUpgrade element provides nice "syntactic sugar".
Otherwise, you want to look at the Upgrade element.
On Thu, Feb 24, 2011 at 10:22 AM, Kevin Burton wrote:
> I know this is an old question but I don't know the WiX syntax for
> automatically uninstalling an installed product. I l
PS: you don't need supportedRuntime for both /Full and /Client. Full
contains Client so you only need to specify the "lesser" one you need.
On Thu, Feb 24, 2011 at 2:27 PM, Simon Zinkevicius wrote:
>
> Thanks for the help. I was missing step 1. As soon as I added the config
> file
> payload it a
And documentation will get better in the future. I have written the
documentation yet because I've been trying to simplify the creation more...
lots of fiddly little details you have to get connected for it to work.
On Thu, Feb 24, 2011 at 2:31 PM, Simon Zinkevicius wrote:
>
> Everything is now
I agree. This list is awesome.
On Thu, Feb 24, 2011 at 2:47 PM, Uma Harano wrote:
> Thank you so much John and Mat. This forum is awesome.
> I have direction now.
> Uma-
>
> -Original Message-
> From: John Robbins [mailto:j...@wintellect.com]
> Sent: Thursday, February 24, 2011 1:41 PM
>
How does FILEEXISTS get created? It's not a standard property so it must come
from a search or something.
Phil Wilson
-Original Message-
From: Mark Turek [mailto:turekm...@hotmail.com]
Sent: Thursday, February 24, 2011 2:40 PM
To: General discussion for Windows Installer XML too
Subje
In another area of your code look for the element and make
sure you change the Id="" guid there as one necessary step. But, leave
the UpgradeCode unchanged in that same element. Also make sure you
increment your version number to something higher than that one you have
already installed.
Then in
I have WiX code like:
. . . . .
I am trying to automatically uninstall any previous versions of the package
before this installation proceeds. But even with this code when I run the .msi
I get a prompt indicating that I must go to the Control Panel and unin
I came across an old message to this very same mailing group (google
ftw)
http://www.mail-archive.com/wix-users@lists.sourceforge.net/msg17686.htm
l
I am working through the issue I have with string replacement escaping,
just seeing if anyone has come up with a better idea since then
Constraints
Using the following command 'msiexec /i SampleUpgrade.msi REINSTALL=ALL
REINSTALLMODE=vomus' for minor upgrade causes the following rule not to be
obeyed
FILEEXISTS
Is there any way I can do the minor upgrade and have this condition to be
respected so that my services does not get
Everything is now up and running. My problem was that I was not including my
BA config file in the BootstrapperApplication payload. I added the lines
below into my Bundle.wxs and it is all working now.
Thanks for the help guys!
Simon
--
View this message in context:
http://windows-i
Thanks for the help. I was missing step 1. As soon as I added the config file
payload it all started working. Thanks again.
--
View this message in context:
http://windows-installer-xml-wix-toolset.687559.n2.nabble.com/Re-Trouble-implementing-a-tp6060833p6062338.html
Sent from the wix-users mail
I am out of the office until 02/28/2011.
I will be out of the office, with limited email and phone access.
Note: This is an automated response to your message "Re: [WiX-users]
PlugCollectionInto values for VS2010" sent on 2/24/2011 3:27:53 PM.
This is the only notification you will receive w
Im get a "Error 0x8007007f: Failed to get BootstrapperApplicationCreate
entry-point" error in the log. Do I need to defne a
"BootstrapperApplicationCreate" function in my BA library?
--
View this message in context:
http://windows-installer-xml-wix-toolset.687559.n2.nabble.com/Trouble-implement
Thank you so much John and Mat. This forum is awesome.
I have direction now.
Uma-
-Original Message-
From: John Robbins [mailto:j...@wintellect.com]
Sent: Thursday, February 24, 2011 1:41 PM
To: General discussion for Windows Installer XML toolset.; Uma Harano
Subject: RE: [WiX-users] Nee
Or you can steal the code I just posted that shows working with IIS7 and WiX. :)
http://www.wintellect.com/CS/blogs/jrobbins/archive/2011/02/23/web-application-installer-in-wix.aspx
Hope it helps!
John
Wintellect
http://www.wintellect.com
+1-877-968-5528
-Original Message-
From: Skildu
Does anyone have the VS2010 values handy? The Wix 3.5 help only has the VS2205
and VS2008 values listed.
I'm currently using for VS2008:
- Ed
--
Free Software Download: Index, Search & Analyze Logs and other IT dat
Unfortunately there is a completely different set of APIs for working with IIS
7.
Here is the link to the MSDN documentation on the ServerManager Namespace:
http://msdn.microsoft.com/en-us/library/microsoft.web.administration.servermanager(v=vs.90).aspx
Mat Skildum
-Original Message-
Hi,
I am using WiX C # custom action template in Visual Studio 2008. The custom
action I am writing is for listing all the websites on a machine and
displaying it in a msi dialog. The code is very similar to what is found on
this site:
http://blog.torresdal.net/CommentView,guid,FE27427F-FF4F
Check out the CAQuietExec custom action.
-Original Message-
From: Gregg Swanson [mailto:gregg.swan...@microsoft.com]
Sent: Thursday, February 24, 2011 12:54 PM
To: wix-users@lists.sourceforge.net
Subject: [WiX-users] How to issue a "netsh http add urlacl url=.." command at
install time.
I know this is an old question but I don't know the WiX syntax for
automatically uninstalling an installed product. I looked at the documentation
and I got confused with Major/Minor updates/upgrades. In my case if the product
is install I *always* want to uninstall it before proceeding with the
You still need to look at the complete log. Searching for "in use" is a good
start.
Phil Wilson
-Original Message-
From: Sergey Yukhno [mailto:sergey.yuk...@visutechsystem.by]
Sent: Thursday, February 24, 2011 7:32 AM
To: General discussion for Windows Installer XML toolset.
Subject:
What is the recommended technique to use to enter the following command at
install time?
netsh http add urlacl url=https://+:443/EnterpriseService/ user=redmond\edmmtsa
Thanks,
Gregg
--
Free Software Download: Index, Se
Everyone,
I apologize for not getting back sooner with updates on this issue, but I was
able to find a solution. I had to do two things:
* Set up subfeatures to point to APPDATADIR where applicable from the
original example below instead of TARGETDIR as their configurable directory.
This
Hey, Simon.
I had the same problems when first try to write BA on managed code. Rob
Mensching suggested me to see sources of Wix 3.6 installer itself.
wix36-sources\src\Setup\Bundle - location of Wix bootstrapper project
wix36-sources\src\Setup\UX - location of BoostrapperApplication project. It
us
Action 15:27:39: RollbackCleanup. Removing backup files
MSI (s) (2C:A8) [15:27:39:500]: Note: 1: 1321 2: C:\Config.Msi\23320b.rbf
MSI (s) (2C:A8) [15:27:39:500]: Verifying accessibility of file: 23320b.rbf
Info 1903. Scheduling reboot operation: Deleting file
C:\Config.Msi\23320b.rbf. Must reboo
Make your custom actions deferred and they will run elevated.
On Tue, Feb 22, 2011 at 9:40 PM, MYFLEX wrote:
>
> Hi all,
>
> our installer will run the different custom actions at the time of
> uninstallation. these custom actions needs the administrator previleges.
> how
> to run my uninstallat
Those are rollback files. They are not likely to be the cause of the reboot.
The log file will probably point out some other files.
On Wed, Feb 23, 2011 at 11:53 PM, Sergey Yukhno <
sergey.yuk...@visutechsystem.by> wrote:
> After change/repair options setups asks for rebooting. In setup log I
> f
I *think* the change came when the new tool to sign cabinets came in. I'm
looking at this code right now myself. I'm wondering if there is a bug in
here somewhere. I'll let you know if I find anything interesting.
On Mon, Feb 21, 2011 at 3:59 PM, Jacques Eloff wrote:
> Hi
>
> I rely on batching
Unfortunately, to get the bind.AssemblyXxx values you need to set the
appropriate File/@Assembly attributes. If you don't go to the GAC, then you
need to set the File/@AssemblyFile and File/@AssemblyApplication to point to
the same file. Its weird WindowsSxS behavior that we probably should have
ab
There will be a log file in %TEMP%. Does it point out any errors?
On Wed, Feb 23, 2011 at 2:14 PM, Simon Zinkevicius wrote:
>
> I also added the following line the the AssemblyInfo.cs in the bootstrapper
> Application library but it still will not run.
>
> [assembly: BootstrapperApplication(type
anyone knows?
--
View this message in context:
http://windows-installer-xml-wix-toolset.687559.n2.nabble.com/How-to-cancel-whole-installation-if-user-cancel-Prerequisites-tp6059116p6059642.html
Sent from the wix-users mailing list archive at Nabble.com.
-
It is very likely the .dll is not included in the MSI package at
build.
Another possibility is the .dll is missing some dependent .dll files.
-Original Message-
From: Colin LeMahieu [mailto:clemah...@gmail.com]
Sent: Wednesday, February 23, 2011 7:26 PM
To: wix-users@lists.sourcef
Hi,
Think there is no way to directly do that as the Difxapp has, as you
stated already, no element for that.
I'd check the issue what is going wrong with the device driver instead
of "Resume on error". Do you have e.g. the correct files integrated in
the Installation ? Once I had such an issue w
Hi,
Setup can't install driver via DIFXApp and installation process stopped
with error.
How to just show error message and continue. Difxapp element doesn't
have necessary option.
Sergey Yukhno.
--
Free Software Downlo
38 matches