Hi all,
new to the list and thought I should start out with a question :)
At work we recently migrated to Wix 3 and visual studio 2008. I need to
build some installers that will install our visual studio packages.
In our previous version we used wix 2 and targeted Visual Studio 2005. At
that mome
In reality I just don't want the uninstall can be interrupted.
It is possible? Thank you.
2009/7/14 zhihai guo
> Thank you for your answer.
>
> And can I disable the "cancel" button of the prepareDlg and the
> progressDlg when uninstall?
>
>
>
> 2009/7/3 Rob Mensching
>
> This was asked pre
Hi,
I suppose those references you saw being used were references to .wixlib
projects or Wix Library Projects.
Those types of projects can indeed be referenced in Wix projects and (afaik)
are mainly used for reusable wix sections.
Not sure if regular wix projects can be referenced. That would see
Thank you for your answer.
And can I disable the "cancel" button of the prepareDlg and the
progressDlg when uninstall?
2009/7/3 Rob Mensching
> This was asked pretty recently.
>
> You don't.
>
> zhihai guo wrote:
> > Hi
> >
> > Can I control the UI when uninstall in the xml?
> >
> > Thank
I don't know if I am talking sense here. But just wanted to know whether it
is possible to refer a wixproj in another wixproj. I saw a sample project
where they were referring to wixproj file. When I tried to add an wixproj
reference to my project, Visual studio puts up an error saying " make sure
I have x64 Windows XP. I tried to make 64 bit package by setting attribute:
and during compilation got an error:
light.exe : error LGHT0310 : Failed to open package for validation. The
most common cause of this error is validating an x64 package on an x86
system. To fix this error, run validation
No. My customer is using a 3rd party shell type application (Total
Commander) that happens to be 32-bit to run the setup. When launching
the MSI from there, it gets the error. The MSI log shows the calling
process is Msiexec.exe in the SysWow64 folder, so it is the 32-bit one.
This also happens w
Are you actually launching msiexec.exe? The one in the SysWow64 folder rather
than the 64-bit one?
Phil Wilson
-Original Message-
From: Michael Ballou [mailto:mbal...@eeye.com]
Sent: Monday, July 13, 2009 2:47 PM
To: wix-users@lists.sourceforge.net
Subject: [WiX-users] 32-bit app la
Depending on how your 32-bit app calls the install, it's possible that
it's using the 32-bit copy of msiexec.exe, which means that the
System32 folder gets redirected by default, which could mean that the
file doesn't actually exist.
You may be able to use something like ProcessExplorer to verify
" We also ran into this problem. It is just stupid that visual studio projects
use 4 part version numbers and MSI only supports 3."
Visual Studio doesn't. We're talking in the context of major upgrades and the
ProductVersion property. In Visual Studio that's the Version property of the
Setup P
I have a simple 64-bit MSI that I made install 1 64-bit dll to System64
folder.
Under the following circumstances, MSI gets an error:
1. That file already exists in the real C:\Windows\System32 folder
2. The install is launched through a 32-bit app (not explorer.exe).
Anything that can launch an
Yes, that make sense for me. But to use xmlFile I have to link to
wixca.wixlib, how do I do that?
Also when I tried to add Platform node to Package Id I got:
The Package element contains an unexpected attribute 'Platform'
Thanks lots.
Erica
-Original Message-
From: Phil Sayers [mailto
[ProgramFilesFolder] will be automatically set to the appropriate folder.
Windows Installer takes care of this property automatically.
On Mon, Jul 13, 2009 at 3:51 PM, Erica Chang (PROJECT) wrote:
> What we are doing is installing sample sites that needs the location of the
> install as environm
To the best of my knowledge
As long as your installer is tagged correctly as a 32bit installer by
setting the Platform attribute of the Package node to "x86" like this:
[PROGRAMFILES] will resolve to "Program Files (x86)" on 64-bit windows, and
"Program Files" on 32bit windows This me
What we are doing is installing sample sites that needs the location of the
install as environment variable in web.config to access a file in the
appsettings section.
However, because our SDK only builds in 32bit, the web.config needs a file
location but I need to detect whether to use %program
Keep in mind it's better to avoid XmlFile / XmlConfig and just rely on standard
IIS custom action functionality, if possible. I don't know enough about your
particular scenario to know if it's possible in this case, but if you can throw
a [ProgramFilesFolder] into your IIS authoring somewhere in
Windows Installer automatically handles translating the ProgramFilesFolder
property for 32-bit vs. 64-bit platforms. Are you using an XMLFile element
to set the web.config value? Use the [ProgramFilesFolder] property within
the XMLFile element, and you should get what you want.
- Don Benson -
Trib
XmlFile is your friend.
-Original Message-
From: Erica Chang (PROJECT) [mailto:eri...@microsoft.com]
Sent: Monday, July 13, 2009 1:59 PM
To: 'wix-users@lists.sourceforge.net'
Subject: [WiX-users] Updating web.config field value depending on if
machine's 64bit or 32bit
Hi,
I have a field
Hi,
I have a field in web.config that needs environment variable of %ProgramFiles%
or %ProgramFiles(x86)% depending on if the machine installing is 64 bit or 32
bit.
Is there a way to substitute the values during install time by detecting this
and setting the appropriate values?
Thanks so much
Doh!
Thanks a lot Bob!
Regards,
Rob
-Original Message-
Date: Sun, 12 Jul 2009 22:49:34 -0400
From: Bob Arnson
Subject: Re: [WiX-users] Hiding passwords in the installation log file
To: "General discussion for Windows Installer XML toolset."
Message-ID: <4a5aa0be.1050...@joyofs
Hi,
>>
>> Hello All,
>>
>> due to political issues (see below) my setups need to be able to
>> upgrade when only the 4th part of the version info changes.
>>
>> Example: V1.0.0.1 needs to upgrade V1.0.0.0. My installers always do
>> major upgrades, the product GUI always changes (that is OK and no
Hello,
This probably isn't a Wix-specific question, but please excuse me for
asking here - I'm after a Wix-based solution.
I have to make the installer for a product that is sold on a
module-by-module basis. The number of the modules is not known beforehand.
A module ships on its own disk, which
Another perfect solution would be to control the Product Version
attribute yourself. Could you put the "political" version number into
the Product/@Name attribute ? That way the bosses would see the number
they want in add/remove programs and you can use Product/@Version as MSI
intended.
-Orig
The perfect solution would be for Windows Installer to understand 4 part
version numbers like every other system on the planet :-)
One other point, I schedule RemoveExistingProducts after InstallValidate, it
gets a bit more messy if this is not the case.
Neil
Neil Sleightholm
X2 Systems Lim
hi Vijay,
please go thru the following link as it will give u very basic info about
wix with separate from other setup creation tools available in market.
http://blogs.newsgator.com/inbox/2007/06/why_wix.html
if you are not doin anything in the UI sequence... that means u dont need to
modify t
Hello Neil,
thank you - I didn't find this one. It is not perfect, but sufficiently good
:-). If someone can tell me the perfect solution, I'm still open to it.
Thanks again!
Dirk
On Mon, Jul 13, 2009 at 12:00, Neil Sleightholm wrote:
> I had a similar problem the way I got round it was to s
I had a similar problem the way I got round it was to set the upgrade code to
include the maximum version, e.g. UpgradeVersion/@IncludeMaximum="yes". This
will generate an ICE61 which you will need to ignore. This isn't perfect as
1.2.3.4 will be downgraded by 1.2.3.3 but if you are sure two rel
Hello All,
due to political issues (see below) my setups need to be able to upgrade
when only the 4th part of the version info changes.
Example: V1.0.0.1 needs to upgrade V1.0.0.0. My installers always do major
upgrades, the product GUI always changes (that is OK and not an issue to
discuss).
Af
Hello all,
I'm facing the problem while trying to make a dialog for choosing start menu
folder for creating application shortcut.
There are 2 controls on the dialog: Edit for entering new folder name (if
user chooses to create a new folder for shortcut) and ListBox in which
existing folders are
29 matches