Re: [WiX-users] Distinguish between SQL integrated security and normal authentication

2008-12-11 Thread tgoffice
Has anyone some 50 cents? Any help would be appreciated. Thomas -- View this message in context: http://n2.nabble.com/Distinguish-between-SQL-integrated-security-and-normal-authentication-tp1642658p1646877.html Sent from the wix-users mailing list archive at Nabble.com. --

[WiX-users] Verification of user account

2008-12-11 Thread Anupama Nair
Hi, Can somebody lead me to a CA or some other way through which I can validate the user account given in the UI. As in next to my Username text box is a button (Check Name) which should validate/verify the domain user name that has been entered in the textbox. Thanks in advance, Anupama

Re: [WiX-users] Invalid ICE61 on major upgrade in WiX 3 (3.0.4805.0)

2008-12-11 Thread Alexander Shevchuk
Sorry, forgot to include it. Attributes column in Upgrade table has expected value of 256. Looks like it is an ICE bug. -Original Message- From: Rob Mensching [mailto:rob.mensch...@microsoft.com] Sent: Thursday, December 11, 2008 4:50 PM To: General discussion for Windows Installer X

Re: [WiX-users] CA called from DoAction

2008-12-11 Thread Bob Arnson
Dale Quigg wrote: > I have a custom dialog and when I press "Next", I want a custom action to > fire to check a value in an edit box. If the CA detects an error, I want it > to display a dialog (which does not work apparently due to the communication > issue with MsiProcessMessage) and then set

Re: [WiX-users] Invalid ICE61 on major upgrade in WiX 3 (3.0.4805.0)

2008-12-11 Thread Rob Mensching
You might double check to make sure the MSI's Upgrade table has the right bits. If those are wrong, then it's a WiX bug. If those are correct, it's probably an ICE61 bug. -Original Message- From: Alexander Shevchuk [mailto:alexander.shevc...@microsoft.com] Sent: Thursday, December 11,

Re: [WiX-users] CA called from DoAction

2008-12-11 Thread Dale Quigg
> Date: Thu, 11 Dec 2008 15:49:45 -0700 > From: Richard > Subject: Re: [WiX-users] CA called from DoAction > >> "The context/handle is different from within DoAction ControlEvent >> rather then sequenced CA. MsiProcessMessage calls won't work." >> My testing confirms this. Is there any reasonabl

[WiX-users] Invalid ICE61 on major upgrade in WiX 3 (3.0.4805.0)

2008-12-11 Thread Alexander Shevchuk
I am pretty sure I did not have this ICE before installing 3.0.4805.0. Here is an upgrade table I am using: After installing 4805, I am getting: ICE61: This product should remove only older versions of itself. The Maximum version is not less than the current product. (1.0.1.0 1.0.

Re: [WiX-users] Unexpected error LGHT0204 on Maximum in UpdateVersion

2008-12-11 Thread Rob Mensching
It's not light that is actually reporting the error, it's ICE61. You can see the documentation in the MSI SDK. I'd say the Windows Installer team has a bug in their ICE. -Original Message- From: Gordon Dass Adams [mailto:gor...@mcneel.com] Sent: Thursday, December 11, 2008 15:24 To: wi

[WiX-users] Unexpected error LGHT0204 on Maximum in UpdateVersion

2008-12-11 Thread Gordon Dass Adams
Light.exe 3.0.4318.0 throws an error when the third field of Maximum field is over 32767, such as MaxVersion=2.0.65000 This code generates this error C:\dev\brazil\installer\Installer.wxs(25) : error LGHT0204 : ICE61: Upgrade.VersionMax 2.0.65000 format is wrong Yet MSI Help says "T

Re: [WiX-users] Change in output behavior?

2008-12-11 Thread Bob Arnson
Joe Coplen wrote: > I've just upgraded to a newer v3 build and all of my post-build steps that > expect $(TargetPath) to point to my build output are broken because OutDir, > TargetPath, TargetPdbPath are all pointing to the wrong place. OutDir is > shown as "bin\Debug\", for example whereas th

Re: [WiX-users] CA called from DoAction

2008-12-11 Thread Richard
In article <250bf09281efec4398de83072daed6ef713d32c...@ex3.messagegate.local>, Dale Quigg writes: > I want to verify the directory the user entered in the UI exists. I created a custom action with DTF (Thanks Jason!) that works. However, my understanding from this thread http://tinyurl.

[WiX-users] CA called from DoAction

2008-12-11 Thread Dale Quigg
Hi, I want to verify the directory the user entered in the UI exists. I created a custom action with DTF (Thanks Jason!) that works. However, my understanding from this thread http://tinyurl.com/6ovukx is that; "The context/handle is different from within DoAction ControlEvent rather then seq

[WiX-users] Phil Bevan is out of the office.

2008-12-11 Thread Phil . Bevan
I will be out of the office starting 11/12/2008 and will not return until 15/12/2008. I will respond to your message when I return. This e-mail is sent by or on behalf of the named sender identified above. If: (a) you do not wish to receive any e-mail marketing material from this person in th

Re: [WiX-users] Simple upgrade.

2008-12-11 Thread Ian Elliott (Excell Data Corporation)
There are three types of upgrades: Small update Minor upgrade Major upgrade If you use the minor upgrades your launcher needs to be able to decide if the previous version exists on the machine or not. If it does exist a special command line is needed to install the new over the old. If you auth

[WiX-users] Change in output behavior?

2008-12-11 Thread Joe Coplen
I've just upgraded to a newer v3 build and all of my post-build steps that expect $(TargetPath) to point to my build output are broken because OutDir, TargetPath, TargetPdbPath are all pointing to the wrong place. OutDir is shown as "bin\Debug\", for example whereas the build is really dumping

Re: [WiX-users] changing heat registry entries to createAndRemoveOnUninstall

2008-12-11 Thread Rob Mensching
Can you be more specific about what wasn't removed? By default RegistryValues installed should be removed at uninstall. -Original Message- From: David Jackson [mailto:david.jack...@ca.ibm.com] Sent: Thursday, December 11, 2008 13:13 To: General discussion for Windows Installer XML toolse

[WiX-users] Simple upgrade.

2008-12-11 Thread Chris Lord
Hi all, I am somewhat perplexed with the whole upgrade path. I have read and re-read the Wix docs, the MSDN data, months of WiX posts relating to upgrading and anything else I can get my hands on. The more I read, the more confusing it gets and the less I seem to understand. I am hoping someon

Re: [WiX-users] changing heat registry entries to createAndRemoveOnUninstall

2008-12-11 Thread David Jackson
Without Action="createAndRemoveOnUninstall" they weren't removed during uninstall. Is there a better way to do this? From: Rob Mensching To: "General discussion for Windows Installer XML toolset." Date: 12/11/2008 03:27 PM Subject: Re: [WiX-users] changing heat registry entries to createA

Re: [WiX-users] changing heat registry entries to createAndRemoveOnUninstall

2008-12-11 Thread Rob Mensching
Why do you want to add @Action to the Registry key. The default "none" should be sufficient for this case. -Original Message- From: David Jackson [mailto:david.jack...@ca.ibm.com] Sent: Thursday, December 11, 2008 12:07 To: General discussion for Windows Installer XML toolset. Subject: [

[WiX-users] changing heat registry entries to createAndRemoveOnUninstall

2008-12-11 Thread David Jackson
Does anybody have a solution for fixing up RegistryValue elements generated by heat so that I can specify Action="createAndRemoveOnUninstall"? I think this should be doable with XSL but I'm not sure how to go about it. For example: Heat gives me RegistryValues like this: ... I get the re

Re: [WiX-users] Unresolved reference to symbol 'CustomAction:SchedSecureObjects'

2008-12-11 Thread Alan Sinclair
Solved by including wixca.wixlib to light's input From: Alan Sinclair Sent: Wednesday, December 10, 2008 6:13 PM To: wix-users@lists.sourceforge.net Subject: Unresolved reference to symbol 'CustomAction:SchedSecureObjects' I'm trying to add code to set directo

Re: [WiX-users] SQLExtension, check if database exists

2008-12-11 Thread tgoffice
I have written a custom action, thanks for clarifaction Thomas -- View this message in context: http://n2.nabble.com/SQLExtension%2C-check-if-database-exists-tp1613865p1643613.html Sent from the wix-users mailing list archive at Nabble.com. -

Re: [WiX-users] Adding ActionData control to ProgressDlg

2008-12-11 Thread Neil Sleightholm
Take a look here http://neilsleightholm.blogspot.com/2008/08/customised-uis-for-wix.html I think I have covered what you want to do. Neil Neil Sleightholm X2 Systems Limited [EMAIL PROTECTED] From: Dmitry Berkovich [mailto:[EMAI

[WiX-users] Adding ActionData control to ProgressDlg

2008-12-11 Thread Dmitry Berkovich
Hi, I want add ActionData control to ProgressDlg: I tried develop new progress dialog with name "MyProgressDlg". I also changed WixUI_Mondo to MyMondo but it still some other dialogs have reference to original ProgressDlg. What is the best way add new Control to ex

[WiX-users] Distinguish between SQL integrated security and normal authentication

2008-12-11 Thread tgoffice
Hello, what is the most elegant (common way) to distingwhish between sql connection with integrated security and with user name/password. I have a GUI to enter user database server, instance name, user name, password ... to connect to an database. If user name and password are not provided integ