Re: [weewx-user] Barometer and pressure once again

2023-09-04 Thread Tomasz Lewicki
OK, so I was using these terms without knowing them :) poniedziałek, 4 września 2023 o 20:37:41 UTC+2 Greg Troxel napisał(a): > Tomasz Lewicki writes: > > > abbreviations - SLP and ISA :) > > Sea Level Pressure > > https://en.wikipedia.org/wiki/International_Standard_Atmosphere > -- You receiv

Re: [weewx-user] Barometer and pressure once again

2023-09-04 Thread Greg Troxel
Tomasz Lewicki writes: > abbreviations - SLP and ISA :) Sea Level Pressure https://en.wikipedia.org/wiki/International_Standard_Atmosphere -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails

Re: [weewx-user] Barometer and pressure once again

2023-09-04 Thread Tomasz Lewicki
W dniu 3.09.2023 o 14:02, gszla...@gmail.com pisze: No wonder the OP is confused. In Europe, METARs generally don’t have SLP, they have QNH stated as a “Q code” in the actual METAR report. An Altimeter /QNH reading of 1022 would be Q1022 in the METAR report. So typically, QNH > QFF when curr

Re: [weewx-user] Barometer and pressure once again

2023-09-03 Thread gszla...@gmail.com
No wonder the OP is confused. In Europe, METARs generally don’t have SLP, they have QNH stated as a “Q code” in the actual METAR report. An Altimeter /QNH reading of 1022 would be Q1022 in the METAR report. So typically, QNH > QFF when current or average outside temps are greater than the ISA

Re: [weewx-user] Barometer and pressure once again

2023-09-01 Thread Greg Troxel
Tomasz Lewicki writes: > I'm back and starting my reply from Rainer's last question. Yes, I've > read this topic: > https://github.com/weewx/weewx/wiki/Barometer,-pressure,-and-altimeter > on the very beginning. I use only 'pressure' and 'barometer' terms > below, according to definitions from wi

Re: [weewx-user] Barometer and pressure once again

2023-09-01 Thread gszla...@gmail.com
Perhaps I can help as I own both an Ambient and Ecowitt weather station. I recently did a major rewrite of an older Ecowitt barometer calibration procedure and the new procedure should work with any Fine Offset manufactured device with a barometric sensor. Some basics regarding this equip

Re: [weewx-user] Barometer and pressure once again

2023-09-01 Thread Tomasz Lewicki
W dniu 31.08.2023 o 16:55, 'Rainer Lang' via weewx-user pisze: to calibrate your WS-1001 (Ambient version of the FineOffset/EcowittWH24 outdoor array and the WH1080 console) you could just follow the instructions in https://www.wxforum.net/index.php?topic=40730.0 chapter 6 determine the offset a

Re: [weewx-user] Barometer and pressure once again

2023-08-31 Thread Tomasz Lewicki
Thank you for advice. I will follow the guide you pointed me to. czwartek, 31 sierpnia 2023 o 16:55:41 UTC+2 Rainer Lang napisał(a): > to calibrate your WS-1001 (Ambient version of the FineOffset/EcowittWH24 > outdoor array and the WH1080 console) you could just follow the > instructions in htt

Re: [weewx-user] Barometer and pressure once again

2023-08-31 Thread 'Rainer Lang' via weewx-user
to calibrate your WS-1001 (Ambient version of the FineOffset/EcowittWH24 outdoor array and the WH1080 console) you could just follow the instructions in https://www.wxforum.net/index.php?topic=40730.0 chapter 6 determine the offset and enter it accordingly (either an offest of change the value,

Re: [weewx-user] Barometer and pressure once again

2023-08-31 Thread Greg Troxel
Tomasz Lewicki writes: > thank you both for thoughts and hints. Indeed, when I wrote "When > calculated by Weewx itself ("software" option enabled in weewx.conf), my > weather station shows 1001 hPa - still too low", I meant what Weewx > calculates and show on my webpage, not on console's disp

Re: [weewx-user] Barometer and pressure once again

2023-08-31 Thread Tomasz Lewicki
Rainer, Greg, thank you both for thoughts and hints. Indeed, when I wrote "When calculated by Weewx itself ("software" option enabled in weewx.conf), my weather station shows 1001 hPa - still too low", I meant what Weewx calculates and show on my webpage, not on console's display - display is

Re: [weewx-user] Barometer and pressure once again

2023-08-30 Thread Greg Troxel
from the wiki page I sent For example, the FineOffset consoles can display either the station pressure (called 'absolute' pressure) or the station pressure plus an offset (called 'relative' pressure). T So Fine Offset equipment just does pressure badly. So get station pressure into weewx,

Re: [weewx-user] Barometer and pressure once again

2023-08-30 Thread Greg Troxel
Tomasz Lewicki writes: > I'm trying to sort out barometer and pressure values. I own HP1001 clone. > Internal T/H/P sensor was calibrated with my friends certified barometer > before. Currently it sensor shows absolute pressure value 936,7 hPa and it > almost perfectly (+/- 1 hPa) aligns with

Re: [weewx-user] Barometer and pressure once again

2023-08-30 Thread 'Rainer Lang' via weewx-user
yes - why not calibrate your console first when you see that the offset between absolute and relative pressure for your location used is wrong, just adjust it 😎 the the first basic step I'd say even though, when your absolute (=local) pressure reading is correct, and your have the weewx option