Re: [vpp-dev] Iperf3 throughtput with vcl on vpp-20.05-rc0 is only half of vpp-20.01

2020-04-18 Thread Florin Coras
Hi, >From your vcl configs it seems your fifo sizes are only 32kB. You should >probably increase those, for instance, try with 1MB. If that’s not the issue, other suggestions: - try to pin with taskset iperf to a cpu on the same numa as your nic (check that with sh hardware) - dump the state

[vpp-dev] Iperf3 throughtput with vcl on vpp-20.05-rc0 is only half of vpp-20.01

2020-04-18 Thread jiangxiaoming
[Edited Message Follows] Iperf3 throughtput with vcl on vpp-20.05-rc0 is only half of vpp-20.01. Below is the test topology: +-+  +-+ |iperf3/Server|  |iperf3/client| +-+  +-+ |

[vpp-dev] Iperf3 throughtput with vcl on vpp-20.05-rc0 is only half of vpp-20.01

2020-04-18 Thread jiangxiaoming
Iperf3 throughtput with vcl on vpp-20.05-rc0 is only half of vpp-20.01. Below is the test topology: +-+  +-+ |iperf3/Server| |iperf3/client| +-+  +-+ | | +-+