Same daughtecrards on both? Same UHD version?
Can you check with a scope the presence of 10Mhz on the ref out?
Sent from my iPhone
> On Mar 3, 2019, at 2:46 PM, Achilleas Anastasopoulos
> wrote:
>
> Hi Marcus
>
> I am not interested in phase allignement but only frequency alignment.
>
> Th
Hi Marcus
I am not interested in phase allignement but only frequency alignment.
This is EXACTLY what I have observed in my successful experiment with the
N210s and the MIMO cable.
Is there any reason why this setup will not produce what I have described?
Achilleas
On Sun, Mar 3, 2019 at 2:
This will semi work. You won’t get useful phase alignment between the streams.
Sent from my iPhone
> On Mar 3, 2019, at 12:41 PM, Achilleas Anastasopoulos
> wrote:
>
> Hi Marcus,
>
> I forgot to say that the two USRPs are on different computers...
>
> Do I still need to have mb1 getting the
Hi Marcus,
I forgot to say that the two USRPs are on different computers...
Do I still need to have mb1 getting the external clock?
thanks
Achilleas
___
USRP-users mailing list
USRP-users@lists.ettus.com
http://lists.ettus.com/mailman/listinfo/usrp-use
On 03/02/2019 04:41 PM, Achilleas Anastasopoulos via USRP-users wrote:
Hi all,
In the past I had performed the following successful experiment using
two N210's connected with a MIMO cable:
I transmitted a single sinusoid of 10KHz through on USRP at a carrier
of 1GHz and received it on anothe