Hi Guys,
Thanks a lot for the tips. I stopped the network manager and everything
worked fine.
I am also copying some notes I took as a part of learning from this bug.
Since these emails are archived, I thought it might help someone else
having this issue.
Network Manager issues:
The server ne
If that helps, you can disable individual interfaces from being managed.
In /etc/NetworkManager/NetworkManager.conf
add the lines:
[keyfile]
unmanaged-devices=interface-name:sfp0
Ron
On 9/3/20 12:41, Venkatesh Sathyanarayanan via USRP-users wrote:
Thanks a lot Michael and cedric for taking ti
Thanks a lot Michael and cedric for taking time to answer my questions.. I
will try to stop the network manager and see if that helps.
Regards
Venkatesh
On Thursday, September 3, 2020, Michael Dickens
wrote:
> In my experience, this happens when the networking isn't stable, which can
> be for a
In my experience, this happens when the networking isn't stable, which can
be for all sorts of reasons:
* connectors / cables are flaky;
* host SW configuration isn't quite correct;
* actual NIC has issues, HW or FW / configuration;
* USRP NIC has issues ... very rare, but it can happen;
* USR
maybe network manager (if you have that thing running) on the
computer doing funny things with the interface? I had this
issue with some 4g dongles in the past.
On 2020-09-03 01:01, Venkatesh Sathyanarayanan via USRP-users wrote:
Hi,
Small correction:
*Questions:*
I notice that the test stops
On 09/02/2020 07:01 PM, Venkatesh Sathyanarayanan via USRP-users wrote:
Hi,
Small correction:
*Questions:*
I notice that the test stops when the link goes down every 45 seconds.
This happens for all types of tests(with and without GUI).
Kindly let me know how to debug this - i.e. why the link
Hi,
Small correction:
*Questions:*
I notice that the test stops when the link goes down every 45 seconds. This
happens for all types of tests(with and without GUI).
Kindly let me know how to debug this - i.e. why the link goes down every 45
seconds?
Regards
Venkatesh
On Wed, Sep 2, 2020 at 3:10
Hi,
*Setup details:*
I am using an USRP N310 and I have the host computer connected to the USRP
via SFP cable. I additionally have a serial connection between the two and
have a screen session running.
*Observation:*
On the screen session, I noticed the following messages:
[ 2151.041079] nixge 4