Thank you,Neel
2018-05-20 2:52 GMT+08:00 Neel Pandeya :
> Hello Jong:
>
> I think Robin answered this in a separate thread with you, so I'm just
> responding to conclude this thread.
>
> The behavior that you describe is a result of a corrupted bit in the AVR
> EEPROM firmware that results in the
Hello Jong:
I think Robin answered this in a separate thread with you, so I'm just
responding to conclude this thread.
The behavior that you describe is a result of a corrupted bit in the AVR
EEPROM firmware that results in the power-on sequence requiring the power
button to be pushed. This corru
Hi all,
We know that when we insert network cable to e313,the e313 will power on
and press power button is not needed. Now,we take DC power supply(12V) for
e313,and we must press power button of e310 and then power on.
It is normal?How can we achieve power on and no press power button with DC
power