I have made some more tests on my Win7Pro and saw that MS was clever enough
to raise the 1 handles per process limit in newer Windows'. I think the
new limit is something like 24-25000. To support 20k connections with ICS,
we still need to raise the WH_MAX_MSG though. Any comment on making this
Hi and welcome back Francois.
On Sun, May 23, 2010 at 12:12 PM, Francois PIETTE wrote:
> Not sure how the debug GUI exe works but I found a solution for the
>> service:
>>
>> In ...WndControl.pas,
>>
>> const
>> TIcsWndControlVersion = 110;
>> CopyRight : String = ' TIcsWndControl (c) 200
Not sure how the debug GUI exe works but I found a solution for the
service:
In ...WndControl.pas,
const
TIcsWndControlVersion = 110;
CopyRight : String = ' TIcsWndControl (c) 2002-2008 F. Piette V1.10
';
WH_MAX_MSG = 400; <== MODIFIED THIS from 100
so that it woul
Hi Arno,
Not sure how the debug GUI exe works but I found a solution for the service:
In ...WndControl.pas,
const
TIcsWndControlVersion = 110;
CopyRight : String = ' TIcsWndControl (c) 2002-2008 F. Piette V1.10 ';
WH_MAX_MSG = 400; <== MODIFIED THIS from 100
so tha
Fastream Technologies wrote:
> Yes I see but under the same computer, same Win7Pro, same 4GB RAM,
> the GUI -debug- project that does exactly the same thing works very
> well!!
I guess both use the same ICS, isn't it?
So most likely something in your service-code makes the difference.
--
Arno Ga
Yes I see but under the same computer, same Win7Pro, same 4GB RAM, the GUI
-debug- project that does exactly the same thing works very well!! I am
trying to push the 32-bit compiler to its limits.
On Thu, May 20, 2010 at 8:17 PM, Arno Garrels wrote:
> Fastream Technologies wrote:
> > Here is wha
Fastream Technologies wrote:
> Here is what I have done more: - attached the debugger to service
> process and got,
> http://www.fastream.com/ics/icserror8.png
ERROR_NOT_ENOUGH_MEMORY 8 (0x8)
--
Arno Garrels
>
> Hope you can help,
>
> SZ
>
> On Thu, May 20, 2010 at 7:10 PM, Fastream Technolo
Here is what I have done more: - attached the debugger to service process
and got,
http://www.fastream.com/ics/icserror8.png
Hope you can help,
SZ
On Thu, May 20, 2010 at 7:10 PM, Fastream Technologies
wrote:
> Hello,
>
> When under stress test, the service -project- crashes and needs a Task
>
Hello,
When under stress test, the service -project- crashes and needs a Task
manager kill with more than 5,860 connections. When I use the same source
with GUI project, it easily scales up to 20,000 connections. Any idea what
we should be taking care of that we have not??
Thanks,
SZ
--
To unsub